A new pulsatile volumetric device with biomorphic valves for the in vitro study of the cardiovascular system.

A pulsatile mock loop system was designed and tested. This prototype represents a versatile, adjustable, and controllable experimental apparatus for in vitro studies of devices meant to interface with the human circulatory system. The pumping system consisted of a ventricular chamber featuring two biomorphic silicone valves as the inlet and outlet valves. The chamber volume is forced by a piston pump moved by a computer-controlled, low-inertia motor. Fluid dynamic tests with the device were performed to simulate physiological conditions in terms of cardiac output (mean flow of 5 and 6 L/min, with beat rates from 60 to 80 bpm), of rheological properties of the processed fluid, and of systemic circulation impedance. The pulsating actuator performed a good replication of the physiological ventricular behavior and was able to guarantee easy control of the waveform parameters. Experimental pressure and flow tracings reliably simulated the physiological profiles, and no hemolytic subatmospheric pressures were revealed. The performance of the prototype valves was also studied in terms of dynamic and static backflow, effective orifice area, and pressure loss, resulting in their applicability for this device. Mechanical reliability was also tested over 8 h. The device proved to be a reliable lab apparatus for in vitro tests; the pumping system also represents a first step toward a possible future application of pulsating perfusion in the clinic arena, such as in short-term cardiac assist and pulsatile cardiopulmonary bypass.

[1]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[2]  Eric Bertrand,et al.  In vitro atrial flow dynamics: normal conditions versus atrial fibrillation. , 2004, Journal of biomechanics.

[3]  Patrick Segers,et al.  Mock loop testing of On-x prosthetic mitral valve with Doppler echocardiography. , 2002, Artificial organs.

[4]  G B Fiore,et al.  Hydraulic functional characterisation of aortic mechanical heart valve prostheses through lumped-parameter modelling. , 2002, Journal of biomechanics.

[5]  N. Westerhof,et al.  Input Impedance of the Pulmonary Arterial System in Normal Man: Effects of Respiration and Comparison to Systemic Impedance , 1984, Circulation research.

[6]  E. Berjano,et al.  Platelet Dysfunction in Cardiopulmonary Bypass: An Experimental Comparative Study between a Centrifugal and a New Pulsatile Pump , 2003, The International journal of artificial organs.

[7]  Giancarlo Pennati,et al.  Mathematical modeling of fluid dynamics in pulsatile cardiopulmonary bypass. , 2004, Artificial organs.

[8]  M K Sharp,et al.  Development of a hydraulic model of the human systemic circulation. , 1999, ASAIO journal.

[9]  J. Wielogorski,et al.  The effects of subatmospheric pressure on the haemolysis of blood. , 1975, Journal of biomechanics.

[10]  Ajit P Yoganathan,et al.  The material properties of the native porcine mitral valve chordae tendineae: an in vitro investigation. , 2006, Journal of biomechanics.

[11]  T. Dohi,et al.  Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator. , 2008, Artificial organs.

[12]  Andrew Galbraith,et al.  A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices. , 2005, Artificial organs.

[13]  B. Yoffe,et al.  Experimental study of a novel suture-less aortic anastomotic device. , 2007, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[14]  R Fumero,et al.  Fluid dynamic models as a guide to determine prosthetic heart valve diameter. , 1986, Journal of biomechanics.

[15]  R GORLIN,et al.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. , 1951, American heart journal.

[16]  R. Figliola,et al.  In vitro study of flow regulation for pulmonary insufficiency. , 2007, Journal of biomechanical engineering.

[17]  Jeffrey R. Gohean,et al.  Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position. , 2006, Journal of biomechanical engineering.

[18]  Akif Undar,et al.  An Evaluation of the Benefits of Pulsatile versus Nonpulsatile Perfusion during Cardiopulmonary Bypass Procedures in Pediatric and Adult Cardiac Patients , 2006, ASAIO journal.

[19]  George M Pantalos,et al.  Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device. , 2007, The Journal of thoracic and cardiovascular surgery.

[20]  Gerson Rosenberg,et al.  Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support. , 2005, ASAIO journal.

[21]  P. Walker,et al.  The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro. , 2001, The Journal of heart valve disease.

[22]  L. Katz,et al.  CLINICAL OBSERVATIONS ON THE DYNAMICS OF VENTRICULAR SYSTOLE: I. AURICULAR FIBRILLATION , 1923 .

[23]  K Sagawa,et al.  Translation of Otto Frank's paper "Die Grundform des Arteriellen Pulses" Zeitschrift für Biologie 37: 483-526 (1899). , 1990, Journal of molecular and cellular cardiology.

[24]  Yi Wu,et al.  Construction of an Artificial Heart Pump Performance Test System , 2006, Cardiovascular engineering.

[25]  George M Pantalos,et al.  Characterization of an Adult Mock Circulation for Testing Cardiac Support Devices , 2004, ASAIO journal.

[26]  D M McQueen,et al.  In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates. , 1978, The Journal of thoracic and cardiovascular surgery.

[27]  A. Ündar,et al.  Review Article: Comparison of perfusion modes on microcirculation during acute and chronic cardiac support: is there a difference? , 2007, Perfusion.

[28]  A. Yoganathan,et al.  Mitral Valve Function and Chordal Force Distribution Using a Flexible Annulus Model: An In Vitro Study , 2005, Annals of Biomedical Engineering.

[29]  Silvia Schievano,et al.  Experimental setup to evaluate the performance of percutaneous pulmonary valved stent in different outflow tract morphologies. , 2009, Artificial organs.

[30]  Aron Andrade,et al.  Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases. , 2008, Artificial organs.

[31]  E. Berjano,et al.  Injury in organs after cardiopulmonary bypass: a comparative experimental morphological study between a centrifugal and a new pulsatile pump. , 2004, Artificial organs.

[32]  Alberto Redaelli,et al.  Development of a New Disposable Pulsatile Pump for Cardiopulmonary Bypass: Computational Fluid-Dynamic Design and In Vitro Tests , 2002, ASAIO journal.

[33]  Swanson Wm,et al.  A simple cardiovascular system simulator: design and performance. , 1977 .

[34]  C. Pierrakos,et al.  Comparison of Pulsatile With Nonpulsatile Mechanical Support in a Porcine Model of Profound Cardiogenic Shock , 2005, ASAIO journal.

[35]  J F Cornhill,et al.  An aortic--left ventricular pulse duplicator used in testing prosthetic aortic heart valves. , 1977, The Journal of thoracic and cardiovascular surgery.

[36]  H. Reul,et al.  Fluid Mechanics of Natural Cardiac Valves , 1978 .