Experimental Performance of AFRP Concrete Bridge Deck Slab with Full-Depth Precast Prestressed Panels

While application of full-depth precast bridge deck panels may be appealing because of an accelerated construction schedule and improved safety conditions, corrosion of steel reinforcement is a major factor affecting the structural durability of precast panels and overall serviceability of a bridge deck. Herein, the concept of using aramid fiber reinforced polymer (AFRP) bars as a substitute for conventional steel reinforcement to overcome corrosion issues is verified. For this purpose, a full-scale bridge deck slab consisting of full-depth precast panels reinforced and prestressed with AFRP bars is constructed and experimentally evaluated in terms of load capacity, deformation, crack pattern, and failure mode. The precast panels are reinforced and prestressed in parallel and perpendicular to the traffic directions, respectively, and supported by reinforced concrete beams. Realistic dimensions, boundary conditions, and structural details are physically modeled to represent an actual bridge deck condition, and different concentrated load configurations including wheel and tandem axle loads are applied on both the slab interior span and overhang. The experimental results show the average failure load of the interior spans and overhangs, respectively equal to 3.9 and 1.4 times the maximum factored wheel load, where the deflection serviceability criteria are met and satisfactory deformability performance is achieved.

[1]  Sami H. Rizkalla,et al.  Fibre reinforced polymer reinforcing bars for bridge decks , 2000 .

[2]  John B. Mander,et al.  Experimental Performance of Full-Depth Precast, Prestressed Concrete Overhang, Bridge Deck Panels , 2010 .

[3]  Shobeir Pirayeh Gar Structural Performance of a Full-Depth Precast Bridge Deck System Prestressed and Reinforced with AFRP Bars , 2012 .

[4]  R W James,et al.  FRP REINFORCING BARS IN BRIDGE DECKS: STATE OF THE ART REVIEW , 2000 .

[5]  Jose Medina,et al.  Characteristics of AFRP Bars for Prestressing Applications , 2012 .

[6]  R El-Hacha,et al.  Prestressing Concrete Structures with FRP Tendons (ACI 440.4R-04) , 2005 .

[7]  John B. Mander,et al.  Compound Shear-Flexural Capacity of Reinforced Concrete–Topped Precast Prestressed Bridge Decks , 2011 .

[8]  Brahim Benmokrane,et al.  SERVICEABILITY OF CONCRETE BRIDGE DECK SLABS REINFORCED WITH FIBER-REINFORCED POLYMER COMPOSITE BARS , 2004 .

[9]  B. Benmokrane,et al.  Behavior of concrete bridge deck slabs reinforced with fiber-reinforced polymer bars under concentrated loads , 2005 .

[10]  A. Nanni Guide for the Design and Construction of Concrete Reinforced with FRP Bars (ACI 440.1R-03) , 2005 .

[11]  K. Kobayashi,et al.  SERVICE AND ULTIMATE LOAD BEHAVIOR OF BRIDGE DECK REINFORCED WITH CARBON FRP GRID , 2000 .

[12]  Brahim Benmokrane,et al.  FRP BARS FOR BRIDGES , 2004 .

[13]  P. Soroushian,et al.  LABORATORY EVALUATION AND FIELD APPLICATION OF CONCRETE REINFORCEMENT WITH ARAMID FIBER-REINFORCED POLYMER BARS , 2002 .

[14]  Mahmoud A. Issa,et al.  EXPERIMENTAL BEHAVIOR OF FULL-DEPTH PRECAST CONCRETE PANELS FOR BRIDGE REHABILITATION , 2000 .

[15]  Sami H. Rizkalla,et al.  A smart highway bridge in Canada , 1994 .

[16]  John B. Mander,et al.  Comparative Experimental Performance of Bridge Deck Slabs with AFRP and Steel Precast Panels , 2013 .

[17]  Brahim Benmokrane,et al.  Flexural Behavior of One-Way Concrete Slabs Reinforced by Fiber Reinforced Plastic Reinforcements , 1998 .

[18]  Issam E. Harik,et al.  One-Way Slabs Reinforced with Glass Fiber Reinforced Polymer Reinforcing Bars , 1999, SP-188: 4th Intl Symposium - Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures.

[19]  Ahmed K. El-Sayed,et al.  SHEAR STRENGTH OF ONE-WAY CONCRETE SLABS REINFORCED WITH FIBER-REINFORCED POLYMER COMPOSITE BARS , 2005 .