Fundamental aspects of excitation and propagation of on-line partial discharge signals in three-phase medium voltage cable systems

On-line partial discharge (PD) detection of three-phase belted medium voltage cable connections results in a number of interpretation differences as compared to off-line measurements where only one phase is energized. The induced currents and charges in the phase conductors and earth screen upon a PD not only depend on the discharge site, but also become phase angle dependent. Furthermore, simulations show that the PD distribution itself varies with the amount of eccentricity of the rotating electric field and may differ from the off-line distributions obtained with a linear field. Finally, the PD propagation in a multi-conductor cable also alters the signals measured at the cable terminals. In this paper, induced charges and PD distributions are studied by means of computer simulation. The cable propagation characteristics are verified by measurements.

[1]  John J. Soraghan,et al.  Detection of PD utilizing digital signal processing methods. Part 3: Open-loop noise reduction , 2001 .

[2]  C. R. Paul,et al.  Decoupling the multiconductor transmission line equations , 1996 .

[3]  E. Gulski,et al.  On-site PD diagnostics of power cables using oscillating wave test system , 1999 .

[4]  N. Ahmed,et al.  Partial discharge measurements in distribution class extruded cables , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[5]  T. Tanaka Partial discharge pulse distribution pattern analysis , 1995 .

[6]  K. Reiss,et al.  Efficient analysis of coupled multiconductor transmission lines , 1999, 1999 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.99EX147).

[7]  E. Gulski,et al.  Fundamental aspects of on-line PD measurements on distribution power cables , 2001, ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117).

[8]  W. R. Rutgers,et al.  On-line partial discharge monitoring of HV components , 1999 .

[9]  C. Kane,et al.  Practical experiences of on-line partial discharge measurements on a variety of medium voltage electrical equipment , 1998, Record of Conference Papers. IEEE Industry Applications Society 45th Annual Petroleum and Chemical Industry Conference (Cat. No.98CH36234).

[10]  M. S. Mashikian Partial discharge location as a diagnostic tool for power cables , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[11]  J. Wetzer,et al.  Prebreakdown currents: Basic interpretation and time-resolved measurements , 1989 .

[12]  D. W. Gross,et al.  Characteristics of phase resolved partial discharge pattern in spherical voids , 1998, 1998 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.98CH36257).

[13]  W. Shockley Currents to Conductors Induced by a Moving Point Charge , 1938 .

[14]  H. Elze,et al.  Procedure for evaluation of dielectric properties based on complex discharge analyzing (CDA) , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[15]  C. L. Bowmer On-line diagnostic trials on London Electricity's 11 kV cable system , 2000 .

[16]  E. Gulski,et al.  Classification of partial discharges , 1993 .

[17]  S. Ramo Currents Induced by Electron Motion , 1939, Proceedings of the IRE.

[18]  E.F. Steenis,et al.  Partial discharge diagnostics of long and branched medium-voltage cables , 2001, ICSD'01. Proceedings of the 20001 IEEE 7th International Conference on Solid Dielectrics (Cat. No.01CH37117).