Electricity production and cooling energy savings from installation of a building-integrated photovoltaic roof on an office building

Abstract Reflective roofs can reduce demand for air conditioning and warming of the atmosphere. Roofs can also host photovoltaic (PV) modules that convert sunlight to electricity. In this study we assess the effects of installing a building integrated photovoltaic (BIPV) roof on an office building in Yuma, AZ. The system consists of thin film PV laminated to a white membrane, which lies above a layer of insulation. The solar absorptance of the roof decreased to 0.38 from 0.75 after installation of the BIPV, lowering summertime daily mean roof upper surface temperatures by about 5 °C. Summertime daily heat influx through the roof deck fell to ±0.1 kWh/m 2 from 0.3–1.0 kWh/m 2 . However, summertime daily heat flux from the ventilated attic into the conditioned space was minimally affected by the BIPV, suggesting that the roof was decoupled from the conditioned space. Daily PV energy production was about 25% of building electrical energy use in the summer. For this building the primary benefit of the BIPV appeared to be its capacity to generate electricity and not its ability to reduce heat flows into the building. Building energy simulations were used to estimate the cooling energy savings and heating energy penalties for more typical buildings.

[1]  Haider Taha,et al.  Mesoscale meteorological and air quality impacts of increased urban albedo and vegetation , 1997 .

[2]  A. Rosenfeld,et al.  Global cooling: increasing world-wide urban albedos to offset CO2 , 2009 .

[3]  H. Akbari,et al.  Measuring solar reflectance—Part I: Defining a metric that accurately predicts solar heat gain , 2010 .

[4]  K. Oleson,et al.  Effects of white roofs on urban temperature in a global climate model , 2010 .

[5]  Hashem Akbari,et al.  Measured energy savings from the application of reflective roofs in two small non-residential buildings , 2003 .

[6]  H. Akbari,et al.  Radiative forcing and temperature response to changes in urban albedos and associated CO2 offsets , 2010 .

[7]  Leo Rainer,et al.  Monitoring the energy-use effects of cool roofs on California commercial buildings , 2004 .

[8]  Ronnen Levinson,et al.  Procedure for measuring the solar reflectance of flat or curved roofing assemblies , 2008 .

[9]  Hashem Akbari,et al.  Measured energy savings and demand reduction from a reflective roof membrane on a large retail store in Austin , 2001 .

[10]  Jeroen C. J. H. Aerts,et al.  Partial costs of global climate change adaptation for the supply of raw industrial and municipal water: a methodology and application , 2010 .

[11]  A. Rosenfeld,et al.  COOL COMMUNITIES: STRATEGIES FOR HEAT ISLAND MITIGATION AND SMOG REDUCTION , 1998 .

[12]  Tapas K. Mallick,et al.  Enhancing the performance of building integrated photovoltaics , 2011 .

[13]  James P. Dunlop,et al.  Photovoltaic Systems , 2007 .

[14]  H. Akbari,et al.  Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas , 2001 .

[15]  Hashem Akbari,et al.  Peak power and cooling energy savings of high-albedo roofs , 1997 .

[16]  Bill Marion,et al.  Performance comparison of a BIPV roofing tile system in two mounting configurations , 2009, 2009 34th IEEE Photovoltaic Specialists Conference (PVSC).

[17]  S. Menon,et al.  Regional climate consequences of large-scale cool roof and photovoltaic array deployment , 2011 .

[18]  Haider Taha,et al.  Modeling the impacts of large-scale albedo changes on ozone air quality in the South Coast Air Basin , 1997 .