Combined sensing platform for advanced diagnostics in exhaled mouse breath

Breath analysis is an attractive non-invasive strategy for early disease recognition or diagnosis, and for therapeutic progression monitoring, as quantitative compositional analysis of breath can be related to biomarker panels provided by a specific physiological condition invoked by e.g., pulmonary diseases, lung cancer, breast cancer, and others. As exhaled breath contains comprehensive information on e.g., the metabolic state, and since in particular volatile organic constituents (VOCs) in exhaled breath may be indicative of certain disease states, analytical techniques for advanced breath diagnostics should be capable of sufficient molecular discrimination and quantification of constituents at ppm-ppb - or even lower - concentration levels. While individual analytical techniques such as e.g., mid-infrared spectroscopy may provide access to a range of relevant molecules, some IR-inactive constituents require the combination of IR sensing schemes with orthogonal analytical tools for extended molecular coverage. Combining mid-infrared hollow waveguides (HWGs) with luminescence sensors (LS) appears particularly attractive, as these complementary analytical techniques allow to simultaneously analyze total CO2 (via luminescence), the 12CO2/13CO2 tracer-to-tracee (TTR) ratio (via IR), selected VOCs (via IR) and O2 (via luminescence) in exhaled breath, yet, establishing a single diagnostic platform as both sensors simultaneously interact with the same breath sample volume. In the present study, we take advantage of a particularly compact (shoebox-size) FTIR spectrometer combined with novel substrate-integrated hollow waveguide (iHWG) recently developed by our research team, and miniaturized fiberoptic luminescence sensors for establishing a multi-constituent breath analysis tool that is ideally compatible with mouse intensive care stations (MICU). Given the low tidal volume and flow of exhaled mouse breath, the TTR is usually determined after sample collection via gas chromatography coupled to mass spectrometric detection. Here, we aim at potentially continuously analyzing the TTR via iHWGs and LS flow-through sensors requiring only minute (< 1 mL) sample volumes. Furthermore, this study explores non-linearities observed for the calibration functions of 12CO2 and 13CO2 potentially resulting from effects related to optical collision diameters e.g., in presence of molecular oxygen. It is anticipated that the simultaneous continuous analysis of oxygen via LS will facilitate the correction of these effects after inclusion within appropriate multivariate calibration models, thus providing more reliable and robust calibration schemes for continuously monitoring relevant breath constituents.

[1]  B. Mizaikoff,et al.  Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors , 2013, Analytical and Bioanalytical Chemistry.

[2]  A. Manolis,et al.  The diagnostic potential of breath analysis. , 1983, Clinical chemistry.

[3]  N. Croitoru,et al.  Development and Optimization of a Mid-Infrared Hollow Waveguide Gas Sensor Combined with a Supported Capillary Membrane Sampler , 2003, Applied spectroscopy.

[4]  James A. Harrington,et al.  A Review of IR Transmitting, Hollow Waveguides , 2000 .

[5]  Christian Krause,et al.  Composite Luminescent Material for Dual Sensing of Oxygen and Temperature , 2006 .

[6]  Kirk S Schanze,et al.  Preparation and spectroscopic properties of multiluminophore luminescent oxygen and temperature sensor films. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[7]  B. Mizaikoff,et al.  Hollow Waveguide Infrared Spectroscopy and Sensing , 2005 .

[8]  B. Mizaikoff,et al.  Breath analysis with broadly tunable quantum cascade lasers. , 2013, Analytical chemistry.

[9]  Guenter Gauglitz,et al.  Direct optical sensors: principles and selected applications , 2005, Analytical and bioanalytical chemistry.

[10]  Sergey M Borisov,et al.  Temperature-sensitive europium(III) probes and their use for simultaneous luminescent sensing of temperature and oxygen. , 2006, Analytical chemistry.

[11]  V. Ribitsch,et al.  New developments of an optochemical measurement system for the continuous monitoring in subcutaneous tissue by microdialysis , 2007, 2007 IEEE Sensors.

[12]  Michael Jetter,et al.  Ultra-sensitive mid-infrared evanescent field sensors combining thin-film strip waveguides with quantum cascade lasers. , 2012, The Analyst.

[13]  Yixiang Duan,et al.  Breath biomarkers in diagnosis of pulmonary diseases. , 2012, Clinica chimica acta; international journal of clinical chemistry.

[14]  Boris Mizaikoff,et al.  Midinfrared sensors meet nanotechnology: Trace gas sensing with quantum cascade lasers inside photonic band-gap hollow waveguides , 2005 .

[15]  V. Ribitsch,et al.  Optochemical Sensor Systems for In-Vivo Continuous Monitoring of Blood Gases in Adipose Tissue and in Vital Organs , 2012 .

[16]  Timothy Day,et al.  External cavity widely tunable quantum cascade laser based hollow waveguide gas sensors for multianalyte detection , 2009 .

[17]  M. Simon,et al.  Instrumentation and Sensors for Human Breath Analysis , 2010 .

[18]  Nathan I. Croitoru,et al.  Hollow waveguide infrared gas sensing for biomedical applications , 2003, SPIE BiOS.

[19]  Alexandra Inberg,et al.  Combination of sorption tube sampling and thermal desorption with hollow waveguide FT-IR spectroscopy for atmospheric trace gas analysis: determination of atmospheric ethene at the lower ppb level. , 2004, Analytical chemistry.

[20]  Simultaneously monitoring of tissue O2 and CO2 partial pressures by means of miniaturized implanted fiber optical sensors , 2009, 2009 IEEE Sensors.

[21]  A. B. Robinson,et al.  Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography. , 1971, Proceedings of the National Academy of Sciences of the United States of America.

[22]  N. Coggeshall,et al.  Pressure Broadening in the Infra‐Red and Optical Collision Diameters , 1947 .

[23]  Ingo Klimant,et al.  Luminescence Lifetime Temperature Sensing Based on Sol-Gels and Poly(acrylonitrile)s Dyed with Ruthenium Metal–Ligand Complexes , 1999 .

[24]  B. Mizaikoff,et al.  Toward the quantification of the 13CO2/12CO2 ratio in exhaled mouse breath with mid-infrared hollow waveguide gas sensors , 2011, Analytical and Bioanalytical Chemistry.

[25]  P. Barnes,et al.  Exhaled biomarkers. , 2006, Chest.

[26]  Boris Mizaikoff,et al.  Hollow-waveguide gas sensing with room-temperature quantum cascade lasers , 2003 .

[27]  B. Mizaikoff,et al.  Real-Time Fourier Transform-Infrared Analysis of Carbon Monoxide and Nitric Oxide in Sidestream Cigarette Smoke , 2006, Applied spectroscopy.

[28]  Boris Mizaikoff,et al.  Characterization of a Mid-Infrared Hollow Waveguide Gas Cell for the Analysis of Carbon Monoxide and Nitric Oxide , 2006, Applied spectroscopy.

[29]  S. Shinoda,et al.  Luminescent lanthanide complexes as analytical tools in anion sensing, pH indication and protein recognition. , 2011, The Analyst.

[30]  S. Paulson,et al.  Human breath emissions of VOCs. , 1999, Journal of the Air & Waste Management Association.

[31]  N. Croitoru,et al.  Combination of a Mid-infrared Hollow Waveguide Gas Sensor with a Supported Capillary Membrane Sampler for the Detection of Organic Compounds in Water , 2003 .

[32]  Continuous monitoring of pO2 and pCO2 by microdialysis indicates physiologic status of the critically ill patients , 2009 .