Monitoring of temperature increase and tissue vaporization during laser interstitial thermotherapy of ex vivo swine liver by computed tomography

Laser interstitial thermotherapy (LITT) is a minimally invasive technique used to thermally destroy tumour cells. Being based on hyperthermia, LITT outcome depends on the temperature distribution inside the tissue. Recently, CT scan thermometry, based on the dependence of the CT number (HU) on tissue temperature (T) has been introduced during LITT; it is an attractive approach to monitor T because it overcomes the concerns related to the invasiveness. We performed LITT on nine ex vivo swine livers at three different laser powers, (P=1.5 W, P=3 W, P=5 W) with a constant treatment time t=200 s; HU is averaged on two ellipsoidal regions of interest (ROI) of 0.2 cm2, placed at two distances from the applicator (d=3.6 mm and d=8.7 mm); a reference ROI was placed away from the applicator (d=30 mm). The aim of this study is twofold: 1) to evaluate the effect of the T increase in terms of HU variation in ex vivo swine livers undergoing LITT; and 2) to estimate the P value for tissue vaporization. To the best of our knowledge, this is the first study focused on the HU variation in swine livers undergoing LITT at different P. The reported findings could be useful to assess the effect of LITT on the liver in terms of both T changes and tissue vaporization, with the aim to obtain an effective therapy.

[1]  D B Denham,et al.  In Situ temperature measurements with thermocouple probes during laser interstitial thermotherapy (LITT): Quantification and correction of a measurement artifact , 1998, Lasers in surgery and medicine.

[2]  G M Bydder,et al.  The Temperature Dependence of Computed Tomography Attenuation Values , 1979, Journal of computer assisted tomography.

[3]  Thomas Schmitz-Rode,et al.  CT-based temperature monitoring during hepatic RF ablation: Feasibility in an animal model , 2012, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  J. Werner,et al.  Coagulation and temperature distribution in Nd: YAG interstitial laser thermotherapy: an in vitro animal study , 2003, Lasers in Medical Science.

[5]  A Gahleitner,et al.  Temperature dependence of HU values for various water equivalent phantom materials. , 2002, Physics in medicine and biology.

[6]  M D Sherar,et al.  Temperature measurement artefacts of thermocouples and fluoroptic probes during laser irradiation at 810 nm. , 2001, Physics in medicine and biology.

[7]  Thomas Flohr,et al.  Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography , 2011, Journal of computer assisted tomography.

[8]  A H Mahnken,et al.  CT thermometry: will it ever become ready for use? , 2011, International journal of clinical practice. Supplement.

[9]  Thomas Schmitz-Rode,et al.  Multi-slice computed tomography: A tool for non-invasive temperature measurement? , 2010, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[10]  Sergio Silvestri,et al.  Laser Interstitial Thermotherapy for pancreatic tumor ablation: Theoretical model and experimental validation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Sergio Silvestri,et al.  Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas , 2012, IEEE Transactions on Biomedical Engineering.

[12]  T. Flohr,et al.  Feasibility of computed tomography based thermometry during interstitial laser heating in bovine liver , 2011, European Radiology.

[13]  Andre Roggan,et al.  Laser-Induced Interstitial Thermotherapy , 1995 .

[14]  X. X. Zhang,et al.  Dynamic modeling of photothermal interactions for laser-induced interstitial thermotherapy: parameter sensitivity analysis , 2005, Lasers in Medical Science.