Traceable Coulomb blockade thermometry

We present a measurement and analysis scheme for determining traceable thermodynamic temperature at cryogenic temperatures using Coulomb blockade thermometry. The uncertainty of the electrical measurement is improved by utilizing two sampling digital voltmeters instead of the traditional lock-in technique. The remaining uncertainty is dominated by that of the numerical analysis of the measurement data. Two analysis methods are demonstrated: numerical fitting of the full conductance curve and measuring the height of the conductance dip. The complete uncertainty analysis shows that using either analysis method the relative combined standard uncertainty (k  =  1) in determining the thermodynamic temperature in the temperature range from 20 mK to 200 mK is below 0.5%. In this temperature range, both analysis methods produced temperature estimates that deviated from 0.39% to 0.67% from the reference temperatures provided by a superconducting reference point device calibrated against the Provisional Low Temperature Scale of 2000.

[1]  Graham Machin,et al.  Summary of achievements of the European Metrology Research Programme Project “Implementing the new Kelvin” (InK 1) , 2016 .

[2]  J. Pekola,et al.  New Evaluation of $$T-T_{2000}$$T-T2000 from 0.02 K to 1 K by Independent Thermodynamic Methods , 2016 .

[3]  D. Drung,et al.  Primary current-sensing noise thermometry in the millikelvin regime , 2016, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[4]  M. Prunnila,et al.  Nanoelectronic primary thermometry below 4 mK , 2016, Nature Communications.

[5]  J. Fischer Progress towards a new definition of the kelvin , 2015 .

[6]  J. Pekola,et al.  Accurate Coulomb blockade thermometry up to 60 kelvin , 2015, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[7]  J. Pekola,et al.  Investigation of uncertainty components in Coulomb blockade thermometry , 2013 .

[8]  M. Prunnila,et al.  Effect of on-chip filter on Coulomb blockade thermometer , 2012 .

[9]  J. Pekola,et al.  Primary Thermometry in the Intermediate Coulomb Blockade Regime , 2012, 1206.0548.

[10]  J. Pekola,et al.  Metallic Coulomb blockade thermometry down to 10 mK and below. , 2011, The Review of scientific instruments.

[11]  J. Pekola,et al.  Ex situ tunnel junction process technique characterized by Coulomb blockade thermometry , 2010, 1006.2436.

[12]  J. Pekola,et al.  Comparison of Coulomb Blockade Thermometers with the International Temperature Scale PLTS-2000 , 2010, 1006.1609.

[13]  Joachim Fischer,et al.  Determination of the Boltzmann constant—status and prospects , 2006 .

[14]  R. Soulen,et al.  The Provisional Low Temperature Scale from 0.9 mK to 1 K, PLTS‐2000 , 2003 .

[15]  Alexander N. Korotkov,et al.  One dimensional arrays and solitary tunnel junctions in the weak coulomb blockade regime: CBT thermometry , 1997 .

[16]  Alexander N. Korotkov,et al.  Arrays of normal metal tunnel junctions in weak Coulomb blockade regime , 1995 .

[17]  Alexander B. Zorin,et al.  The thermocoax cable as the microwave frequency filter for single electron circuits , 1995 .

[18]  J. Pekola,et al.  Thermometry by arrays of tunnel junctions. , 1994, Physical review letters.

[19]  J. Pekola,et al.  Accurate Coulomb Blockade Thermometry up to 60 , 2018 .

[20]  R. E. Rapp,et al.  Electron Thermalization in Metallic Islands Probed by Coulomb Blockade Thermometry , 2004 .

[21]  G. Schuster,et al.  The Provisional Low Temperature Scale from 0.9 mK to 1 K, PLTS-2000 , 2002 .

[22]  E. Iso Guide to the Expression of Uncertainty in Measurement , 1993 .