Smart implants in orthopedic surgery, improving patient outcomes: a review
暂无分享,去创建一个
Eric H Ledet | Benjamin Liddle | Katerina Kradinova | Sara Harper | Katerina Kradinova | E. Ledet | Benjamin Liddle | Sara E. Harper
[1] G Elfström,et al. Telemetry recordings of forces in the Harrington distraction rod: a method for increasing safety in the operative treatment of scoliosis patients. , 1973, Clinical orthopaedics and related research.
[2] V. Roberts. Strain-gage techniques in biomechanics , 1966 .
[3] N Verdonschot,et al. Frictional heating of total hip implants. Part 1: measurements in patients. , 2001, Journal of biomechanics.
[4] A Rohlmann,et al. Loads on an internal spinal fixation device during walking. , 1997, Journal of biomechanics.
[5] G Elfström,et al. Intravital wireless telemetry of axial forces in Harrington distraction rods in patients with idiopathic scoliosis. , 1971, The Journal of bone and joint surgery. American volume.
[6] D. D’Lima,et al. THE CHITRANJAN RANAWAT AWARD: In Vivo Knee Forces after Total Knee Arthroplasty , 2005, Clinical orthopaedics and related research.
[7] D T Davy,et al. Telemetric force measurements across the hip after total arthroplasty. , 1988, The Journal of bone and joint surgery. American volume.
[8] T R Waugh,et al. Intravital measurements during instrumental correction of idiopathic scoliosis. , 1966, Acta orthopaedica Scandinavica.
[9] Marco P. Soares dos Santos,et al. Power management architecture for smart hip prostheses comprising multiple energy harvesting systems , 2013 .
[10] Antonius Rohlmann,et al. High-Tech Hip Implant for Wireless Temperature Measurements In Vivo , 2012, PloS one.
[11] A Rohlmann,et al. A spinal fixation device for in vivo load measurement. , 1994, Journal of biomechanics.
[12] G Bergmann,et al. Four-channel telemetry system for in vivo measurement of hip joint forces. , 1991, Journal of biomedical engineering.
[13] E Schneider,et al. Loads acting in an intramedullary nail during fracture healing in the human femur. , 2001, Journal of biomechanics.
[14] Christopher Townsend,et al. A multiaxial force-sensing implantable tibial prosthesis. , 2006, Journal of biomechanics.
[15] A. Fleischman,et al. A preliminary biomechanical evaluation in a simulated spinal fusion model. Laboratory investigation. , 2007, Journal of neurosurgery. Spine.
[16] Constantine K. Demetropoulos,et al. Development of a 4-axis load cell used for lumbar interbody load measurements. , 2009, Medical engineering & physics.
[17] Antonius Rohlmann,et al. Loads on a telemeterized vertebral body replacement measured in three patients within the first postoperative month. , 2008, Clinical biomechanics.
[18] In vivo hip joint loads during three methods of walking with forearm crutches. , 2013, Clinical biomechanics.
[19] M.R. Mahfouz,et al. Biocompatible MEMS Electrode Array for Determination of Three-Dimensional Strain , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.
[20] Asimina Kiourti,et al. Wireless Sensors for Smart Orthopedic Implants , 2017, Journal of Bio- and Tribo-Corrosion.
[21] G. Bergmann,et al. Hip joint contact forces during stumbling , 2004, Langenbeck's Archives of Surgery.
[22] E Y Chao,et al. Theoretical analysis of fracture healing monitoring with external fixators. , 1988, Engineering in medicine.
[23] S. Kurtz,et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. , 2007, The Journal of bone and joint surgery. American volume.
[24] A Rohlmann,et al. Comparison of loads on internal spinal fixation devices measured in vitro and in vivo. , 1997, Medical engineering & physics.
[25] G. Bergmann,et al. In vivo hip joint loads and pedal forces during ergometer cycling. , 2017, Journal of biomechanics.
[26] M. Roche,et al. A new method for defining balance: promising short-term clinical outcomes of sensor-guided TKA. , 2014, The Journal of arthroplasty.
[27] Bernadette A. Thomas,et al. Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010 , 2012, The Lancet.
[28] D. D’Lima,et al. AT THE ANNUAL MEETINGS OF THE KNEE SOCIETY The Mark Coventry Award In Vivo Knee Forces During Recreation and Exercise After Knee Arthroplasty , 2008 .
[29] G. Bergmann,et al. Loading of the knee joint during activities of daily living measured in vivo in five subjects. , 2010, Journal of biomechanics.
[30] D. D’Lima,et al. An implantable telemetry device to measure intra-articular tibial forces. , 2005, Journal of biomechanics.
[31] Georg Bergmann,et al. Implantable Sensor Technology: From Research to Clinical Practice , 2012, The Journal of the American Academy of Orthopaedic Surgeons.
[32] T. English,et al. In vivo records of hip loads using a femoral implant with telemetric output (a preliminary report). , 1979, Journal of biomedical engineering.
[33] M. Roche,et al. Increased satisfaction after total knee replacement using sensor-guided technology. , 2014, The bone & joint journal.
[34] Antonius Rohlmann,et al. Total hip joint prosthesis for in vivo measurement of forces and moments. , 2010, Medical engineering & physics.
[35] Annegret Mündermann,et al. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[36] A Rohlmann,et al. Design and calibration of load sensing orthopaedic implants. , 2008, Journal of biomechanical engineering.
[37] J G Werner,et al. Telemeterized load measurement using instrumented spinal internal fixators in a patient with degenerative instability. , 1996, Spine.
[38] G. Bergmann,et al. Design, calibration and pre-clinical testing of an instrumented tibial tray. , 2007, Journal of biomechanics.
[39] R W Mann,et al. A radio telemetry device for monitoring cartilage surface pressures in the human hip. , 1974, IEEE transactions on bio-medical engineering.
[40] Jaimy Lee. Rethinking spine care. , 2014, Modern healthcare.
[41] A Rohlmann,et al. Multichannel strain gauge telemetry for orthopaedic implants. , 1988, Journal of biomechanics.
[42] G. Bergmann,et al. Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.
[43] P S Walker,et al. Telemetry of forces from proximal femoral replacements and relevance to fixation. , 1997, Journal of biomechanics.
[44] N. Rydell. Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.
[45] Guang-Zhong Yang,et al. From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare , 2015, IEEE Transactions on Biomedical Engineering.
[46] Lee E. Weiss,et al. Design of a multi-axis implantable MEMS sensor for intraosseous bone stress monitoring , 2009 .
[47] A Rohlmann,et al. Influence of Muscle Forces on Loads in Internal Spinal Fixation Devices , 1998, Spine.
[48] Antonius Rohlmann,et al. Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants , 2007, IEEE Transactions on Biomedical Engineering.
[49] Ana Luisa Trejos,et al. Versatile smart hip implant technology using 3D metal printing , 2016, 2016 IEEE International Symposium on Circuits and Systems (ISCAS).
[50] P. Walker,et al. Forces and moments telemetered from two distal femoral replacements during various activities. , 2001, Journal of biomechanics.
[51] B. Clasbrummel,et al. Passive Wireless Resonant Galfenol Sensor for Osteosynthesis Plate Bending Measurement , 2012, IEEE Sensors Journal.
[52] G. Bergmann,et al. Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.
[53] William M. Murray,et al. The Bonded Electrical Resistance Strain Gage: An Introduction , 1992 .
[54] J R Atkinson,et al. Radio telemetry for the measurement of intracranial pressure. , 1967, Journal of neurosurgery.
[55] S M Perren,et al. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. , 2000, Injury.
[56] W. Mutschler,et al. Monitoring and healing analysis of 100 tibial shaft fractures , 2002, Langenbeck's Archives of Surgery.
[57] A Rohlmann,et al. Hip endoprosthesis for in vivo measurement of joint force and temperature. , 1999, Journal of biomechanics.
[58] Shuvo Roy,et al. An in vivo Biocompatibility Assessment of MEMS Materials for Spinal Fusion Monitoring , 2003 .
[59] Antonius Rohlmann,et al. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column. , 2007, Medical engineering & physics.
[60] William P. Hnat,et al. Development of a Strain Transferring Sensor Housing for a Lumbar Spinal Fusion Detection System , 2007 .
[61] Antonius Rohlmann,et al. Activities of Everyday Life with High Spinal Loads , 2014, PloS one.
[62] Mark M. Crain,et al. Development of capacitive pure bending strain sensor for wireless spinal fusion monitoring , 2007 .
[63] A. U. Daniels,et al. A new method for continuous intraoperative measurement of Harrington rod loading patterns , 2006, Annals of Biomedical Engineering.
[64] John F. Drazan,et al. Elementary Implantable Force Sensor: For Smart Orthopaedic Implants. , 2013, Advances in biosensors and bioelectronics.
[65] G. Bergmann,et al. Monitoring the load on a telemeterised vertebral body replacement for a period of up to 65 months , 2013, European Spine Journal.
[66] Eric H Ledet,et al. Direct real-time measurement of in vivo forces in the lumbar spine. , 2005, The spine journal : official journal of the North American Spine Society.
[67] Alan D. Lopez,et al. Measuring the global burden of disease. , 2013, The New England journal of medicine.
[68] G Bergmann,et al. Realistic loads for testing hip implants. , 2010, Bio-medical materials and engineering.
[69] Antonius Rohlmann,et al. Loads on a Telemeterized Vertebral Body Replacement Measured in Two Patients , 2008, Spine.
[70] J. L. Cunningham,et al. Monitoring the Mechanical Properties of Healing Bone , 2009, Clinical orthopaedics and related research.
[71] Nathaniel C. Cady,et al. Smart Orthopaedic Implants: Applications in Total Knee Arthroplasty , 2016 .
[72] C. W. Manning,et al. Intravital Measurements During Instrumental Correction of Idiopathic Scoliosis , 1968 .
[73] A Rohlmann,et al. Patient monitoring system for load measurement with spinal fixation devices. , 1996, Medical engineering & physics.
[74] A H Burstein,et al. Telemetering in vivo loads from nail plate implants. , 1982, Journal of biomechanics.
[75] G. Bergmann,et al. ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. , 2009, Clinical biomechanics.
[76] J. Geller,et al. The Use of Electronic Sensor Device to Augment Ligament Balancing Leads to a Lower Rate of Arthrofibrosis After Total Knee Arthroplasty. , 2017, The Journal of arthroplasty.
[77] Aaron D. Price,et al. Conductive polymer sensor arrays for smart orthopaedic implants , 2017, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.
[78] Shantanu Patil,et al. In vivo knee moments and shear after total knee arthroplasty. , 2007, Journal of biomechanics.
[79] Christian M. Puttlitz,et al. Bio-implantable passive on-chip RF-MEMS strain sensing resonators for orthopaedic applications , 2008 .
[80] D. Panescu. Emerging Technologies [wireless communication systems for implantable medical devices] , 2008, IEEE Engineering in Medicine and Biology Magazine.
[81] Peter S. Donzelli,et al. Real-Time In Vivo Loading in the Lumbar Spine: Part 1. Interbody Implant: Load Cell Design and Preliminary Results , 2000, Spine.
[82] Peter T. L. Popkowski Leszczyc,et al. The university of alberta. , 1969, Canadian family physician Medecin de famille canadien.
[83] Michael J Fagan,et al. A Single-Channel Telemetric Intramedullary Nail for In Vivo Measurement of Fracture Healing , 2009, Journal of orthopaedic trauma.
[84] Chafiaâ Hamitouche-Djabou,et al. Design and Evaluation of Instrumented Smart Knee Implant , 2011, IEEE Transactions on Biomedical Engineering.
[85] Kamiar Aminian,et al. Enclosed Electronic System for Force Measurements in Knee Implants , 2014, Sensors.
[86] Raul Morais,et al. Instrumented hip implants: electric supply systems. , 2013, Journal of biomechanics.
[87] Stephen M Howell,et al. An Improved Tibial Force Sensor to Compute Contact Forces and Contact Locations In Vitro After Total Knee Arthroplasty. , 2017, Journal of biomechanical engineering.
[88] S. E. Irby,et al. Instrumented implant for measuring tibiofemoral forces. , 1996, Journal of biomechanics.
[89] S. Taylor,et al. Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises. , 1997, Journal of biomechanics.
[90] Wolf-Joachim Fischer,et al. Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection , 2009 .
[91] John F. Drazan,et al. Archimedean Spiral Pairs with no Electrical Connections as a Passive Wireless Implantable Sensor , 2014, Journal of biomedical technology and research.
[92] R W Mann,et al. Contact pressures from an instrumented hip endoprosthesis. , 1989, The Journal of bone and joint surgery. American volume.
[93] A Rohlmann,et al. Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation Device , 2000, Spine.