Effect of metal and sampling rate on accuracy of Flock of Birds electromagnetic tracking system.

Electromagnetic tracking devices are used in many biomechanics applications. Previous studies have shown that metal located within the working field of direct current electromagnetic tracking devices produces significant errors. However, the effect of sampling rate on the errors produced in a metallic environment has never been studied. In this study, the accuracy of Ascension Technologies' Flock of Birds was evaluated at sampling rates of 20, 60, 100, and 140 Hz, in the presence of both aluminum and steel. Aluminum interference caused an increase in measurement error as the sampling rate increased. Conversely, steel interference caused a decrease in measurement error as the sampling rate increased. We concluded that the accuracy of the Flock of Birds tracking system can be optimized in the presence of metal by careful choice in sampling rate.

[1]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[2]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[3]  A A Amis,et al.  Accuracy of an electromagnetic measurement device and application to the measurement and description of knee joint motion , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  K N An,et al.  Application of a magnetic tracking device to kinesiologic studies. , 1988, Journal of biomechanics.

[5]  G A Dumas,et al.  Calibration of position and angular data from a magnetic tracking device. , 2000, Journal of biomechanics.

[6]  J. P. Paul,et al.  Three-dimensional lumbar spinal kinematics: a study of range of movement in 100 healthy subjects aged 20 to 60+ years. , 2000, Rheumatology.

[7]  R. Ching,et al.  Glenohumeral kinematics and capsulo-ligamentous strain resulting from laxity exams. , 2000, Clinical biomechanics.

[8]  A. Grishman Biomedical sciences instrumentation , 1964 .

[9]  T D Brown,et al.  Factors influencing accuracy of screw displacement axis detection with a D.C.-based electromagnetic tracking system. , 1998, Journal of biomechanical engineering.

[10]  J Cholewicki,et al.  Methodological considerations for using inductive sensors (3SPACE ISOTRAK) to monitor 3-D orthopaedic joint motion. , 1997, Clinical biomechanics.

[11]  Error analysis of a direct current electromagnetic tracking system in digitizing 3-dimensional surface geometries. , 1999 .

[12]  J J Stone,et al.  The use of a direct current electromagnetic tracking device in a metallic environment. , 1996, Biomedical sciences instrumentation.

[13]  Roy Kalawsky,et al.  The science of virtual reality and virtual environments - a technical, scientific and engineering reference on virtual environments , 1993 .

[14]  Error analysis of a direct current electromagnetic tracking system in digitizing 3-dimensional surface geometries. , 1999, Biomedical sciences instrumentation.

[15]  A. Pascoal,et al.  Effects of different arm external loads on the scapulo-humeral rhythm. , 2000, Clinical biomechanics.

[16]  G R Johnson,et al.  Measurement of three-dimensional shoulder movement by an electromagnetic sensor. , 1990, Clinical biomechanics.