Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system.

Due to the lag between sugar intake and the beginning of recovery from hypoglycemia, it is necessary to intervene in an anticipatory way if one wants to prevent, not only detect, hypoglycemia. This article presents the principle of a hypoglycemia prevention system based on risk assessment. The risk situation can be defined as the moment when the system estimates that the glucose concentration is expected to reach a hypoglycemia threshold in less than a given time (e.g., 20 min). Since there are well-known discrepancies between blood and interstitial glucose concentrations, the aim of this experimental study performed in nondiabetic rats was first to validate this strategy, and second to determine whether it can work when the glucose concentration is estimated by a glucose sensor in subcutaneous tissue rather than in blood. We used a model of controlled decrease in blood glucose concentration. A glucose infusion, the profile of which mimicked the appearance of glucose from an intragastric load, was administered either when hypoglycemia was detected or on the basis of risk recognition. Despite the lag between the beginning of the load and that of the increase in blood glucose concentration, which was in all experiments 15-20 min, hypoglycemia was fully prevented without overshoot hyperglycemia in the groups of rats in which the glucose load was started when the hypoglycemia risk was detected, on the basis of either blood or interstitial glucose concentration. This was, of course, not the case when the same glucose load was infused at the detection of the hypoglycemia threshold.

[1]  P. Cryer Iatrogenic Hypoglycemia as a Cause of Hypoglycemia-Associated Autonomic Failure in IDDM: A Vicious Cycle , 1992, Diabetes.

[2]  B. Frier,et al.  Hypoglycaemia, the most feared complication of insulin therapy. , 1994, Diabete & metabolisme.

[3]  G Reach,et al.  Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood. , 1996, Analytical chemistry.

[4]  D. A. Baker,et al.  Dynamic delay and maximal dynamic error in continuous biosensors. , 1996, Analytical chemistry.

[5]  J. Mastrototaro,et al.  Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. , 1999, Diabetes research and clinical practice.

[6]  G. S. Wilson,et al.  Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring. , 2000, American journal of physiology. Endocrinology and metabolism.

[7]  U. Haueter,et al.  Recording of subcutaneous glucose dynamics by a viscometric affinity sensor , 2001, Diabetologia.

[8]  L. Heinemann,et al.  Sensors for glucose monitoring: technical and clinical aspects , 2001, Diabetes/metabolism research and reviews.

[9]  V. Melki,et al.  [Indication of CGMS (Continuous Glucose Monitoring System) in the functionnal investigations of adult type 1 diabetic patients]. , 2001, Diabetes & metabolism.

[10]  H. Hanaire-Broutin,et al.  Intérêt du CGMS (Continuous Glucose Monitoring System) dans l'exploration du diabète de type 1 de l'adulte , 2001 .

[11]  R O Potts,et al.  Detection of hypoglycemia with the GlucoWatch biographer. , 2001, Diabetes care.

[12]  G. S. Wilson,et al.  Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method. , 2002, Biosensors & bioelectronics.

[13]  G. S. Wilson,et al.  A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation. , 2002, Biosensors & bioelectronics.

[14]  G. S. Wilson,et al.  Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. , 2002, Biosensors & bioelectronics.

[15]  Alberto Maran,et al.  Continuous subcutaneous glucose monitoring in diabetic patients: a multicenter analysis. , 2002, Diabetes care.

[16]  Sonia Caprio,et al.  Do sensor glucose levels accurately predict plasma glucose concentrations during hypoglycemia and hyperinsulinemia? , 2002, Diabetes care.

[17]  Toku Takahashi,et al.  Hyperglycemia impairs antro-pyloric coordination and delays gastric emptying in conscious rats , 2002, Autonomic Neuroscience.

[18]  J. Clore,et al.  Prolonged insulin resistance following insulin-induced hypoglycaemia , 1987, Diabetologia.

[19]  F. Sternberg,et al.  Does fall in tissue glucose precede fall in blood glucose? , 1996, Diabetologia.