Analysis of Statistical Methods for Automatic Detection of Congestive Heart Failure and Atrial Fibrillation with Short RR Interval Time Series

In this study, we analyzed three statistical methods for automatic detection of Atrial Fibrillation (AF) and Congestive Heart Failure (CHF) based on the randomness, variability and complexity of the heart beat interval, which is RRI time series. Specifically, we used short RRI time series with 16 beats and employed the normalized Root Mean Square of Successive RR Differences (RMSSD), the sample entropy and the Shannon entropy. The detection performance was analyzed using MIT-BIH AF (n=23), MIT-BIH NSR (n=18), BIDMC CHF (n=13) and the CHF RRI (n=25) databases. Using thresholds by Receiver Operating Characteristic (ROC) curves, we found that the normalized RMSSD provided the highest accuracy. The overall sensitivity, specificity and accuracy for AF and CHF were 0.8649, 0.9331 and 0.9104, respectively. Regarding CHF detection, the detection rate of CHF (NYHA III-IV) was 0.9113 while CHF (NYHA I-II) was 0.7312, which shows that the detection rate of CHF with higher severity is higher than that of CHF with lower severity.

[1]  E. Antman,et al.  ACC/AHA PRACTICE GUIDELINES ACC/AHA Guidelines for the Evaluation and Management of Chronic Heart Failure in the Adult: Executive Summary , 2002 .

[2]  Ihab Hajjar,et al.  Trends in prevalence, awareness, treatment, and control of hypertension in the United States, 1988-2000. , 2003, JAMA.

[3]  M. Scheinman Atrial fibrillation and congestive heart failure: the intersection of two common diseases. , 1998, Circulation.

[4]  Sheng Lu,et al.  Automatic Real Time Detection of Atrial Fibrillation , 2009, Annals of Biomedical Engineering.

[5]  Stephen S. Cha,et al.  Secular Trends in Incidence of Atrial Fibrillation in Olmsted County, Minnesota, 1980 to 2000, and Implications on the Projections for Future Prevalence , 2006, Circulation.

[6]  Alan V. Sahakian,et al.  Use of Sample Entropy Approach to Study Heart Rate Variability in Obstructive Sleep Apnea Syndrome , 2007, IEEE Transactions on Biomedical Engineering.

[7]  Jinseok Lee,et al.  A novel application for the detection of an irregular pulse using an iPhone 4S in patients with atrial fibrillation. , 2013, Heart rhythm.

[8]  J. Ruskin,et al.  Economic burden and co‐morbidities of atrial fibrillation in a privately insured population , 2005, Current medical research and opinion.

[9]  D. Singer,et al.  Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study. , 2001, JAMA.

[10]  W. Stevenson,et al.  Atrial Fibrillation in Congestive Heart Failure , 2010, Cardiology in review.

[11]  R. A. Thuraisingham,et al.  Preprocessing RR interval time series for heart rate variability analysis and estimates of standard deviation of RR intervals , 2006, Comput. Methods Programs Biomed..

[12]  A. Camm,et al.  Heart rate variability and its relation to ventricular arrhythmias in congestive heart failure. , 1994, British heart journal.

[13]  A. Porta,et al.  Nonlinear Indices of Heart Rate Variability in Chronic Heart Failure Patients: Redundancy and Comparative Clinical Value , 2007, Journal of cardiovascular electrophysiology.

[14]  J. R. Moorman,et al.  Accurate estimation of entropy in very short physiological time series: the problem of atrial fibrillation detection in implanted ventricular devices. , 2011, American journal of physiology. Heart and circulatory physiology.

[15]  Yalcin Isler,et al.  Combining classical HRV indices with wavelet entropy measures improves to performance in diagnosing congestive heart failure , 2007, Comput. Biol. Medicine.

[16]  Christopher K. Merrill,et al.  Decrease of cardiac choas in congestive heart failure , 1997 .

[17]  Chao Huang,et al.  A Novel Method for Detection of the Transition Between Atrial Fibrillation and Sinus Rhythm , 2011, IEEE Transactions on Biomedical Engineering.

[18]  T. Thakre,et al.  Loss of lag-response curvilinearity of indices of heart rate variability in congestive heart failure , 2006, BMC cardiovascular disorders.

[19]  L. Goldman,et al.  Correlates of major complications or death in patients admitted to the hospital with congestive heart failure. , 1996, Archives of internal medicine.

[20]  Luca Faes,et al.  Time-Varying Surrogate Data to Assess Nonlinearity in Nonstationary Time Series: Application to Heart Rate Variability , 2009, IEEE Transactions on Biomedical Engineering.

[21]  G. Casolo,et al.  Decreased spontaneous heart rate variability in congestive heart failure. , 1989, The American journal of cardiology.

[22]  Ki H. Chon,et al.  Atrial Fibrillation Detection Using an iPhone 4S , 2013, IEEE Transactions on Biomedical Engineering.

[23]  Ki H. Chon,et al.  Time-Varying Coherence Function for Atrial Fibrillation Detection , 2013, IEEE Transactions on Biomedical Engineering.