Pain relief using smart technology: an overview of a new patient-controlled analgesia device

A new adaptive patient-controlled analgesia (PCA) system designed to improve PCA through the use of a variable bolus dose and a variable background infusion is outlined here. The handset allows patients to rate their pain on a scale of 1-10. Data derived from the handset signals are used by an expert algorithm to repeatedly adapt the drug dosage of the bolus and the background infusion according to both pain intensity and patient response to previous dosages. A feasibility study of the system consisted of a small number of randomized, double-blind, crossover clinical trials. The new system was alternated with a conventional system every 12 h. When the new system was active, 12 h questionnaire pain scores were significantly lower and a trend toward fewer bolus requests was found in alternating intervals. In addition, when the new system was used to commence trials, the number of bolus requests were significantly lower and there was a trend toward lower handset scores, lower questionnaire pain scores, and lower verbal pain scores over the entire trial period. The new adaptive PCA system was well accepted by both patients and clinical staff. The trials successfully established the feasibility of the new system. Further development is being carried out as a result.

[1]  Robert F. Kaiko,et al.  Sources of variation in analgesic responses in cancer patients with chronic pain receiving morphine , 1983, Pain.

[2]  B. J. Harrison,et al.  Patient-controlled analgesia. , 1986, Nursing.

[3]  B. Kavanagh,et al.  Acute pain after thoracic surgery predicts long-term post-thoracotomy pain. , 1996, The Clinical journal of pain.

[4]  L E Mather,et al.  Variables of patient‐controlled analgesia 2. concurrent infusion , 1989, Anaesthesia.

[5]  A Carollo,et al.  A rule-based postoperative pain controller: simulation results. , 1993, International journal of bio-medical computing.

[6]  R D Jones,et al.  An Evaluation of Prolonged Oximetric Data Acquisition , 1992, Anaesthesia and intensive care.

[7]  C. Royse,et al.  The Efficacy of Adding a Continuous Intravenous Morphine Infusion to Patient-Controlled Analgesia (PCA) in Abdominal Surgery , 1995, Anaesthesia and intensive care.

[8]  T. J. Wasylak,et al.  Reduction of post-operative morbidity following patient-controlled morphine , 1990, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[9]  J. Plummer,et al.  Variables of patient‐controlled analgesia 4: the relevance of bolus dose size to supplement a background infusion , 1990, Anaesthesia.

[10]  P. Hartvig,et al.  Postoperative demand for analgesics in relation to individual levels of endorphins and substance P in cerebrospinal fluid , 1982, PAIN.

[11]  A F Merry,et al.  Variables of patient‐controlled analgesia , 1991, Anaesthesia.

[12]  A Montero Matamala,et al.  [Patient-controlled analgesia]. , 1990, Revista espanola de anestesiologia y reanimacion.

[13]  Harry Owen,et al.  A Comparison of Variable-Dose Patient-Controlled Analgesia with Fixed-Dose Patient-Controlled Analgesia , 1996, Anesthesia and analgesia.

[14]  J W Bellville,et al.  Influence of age on pain relief from analgesics. A study of postoperative patients. , 1971, JAMA.

[15]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[16]  A Sibbald,et al.  Control of postoperative pain by interactive demand analgesia. , 1981, British journal of anaesthesia.

[17]  C. Aldecoa,et al.  [Patient-controlled analgesia (PCA) with variable doses: an alternative to conventional PCA?]. , 1992, Revista espanola de anestesiologia y reanimacion.

[18]  M ChapoBortagaray,et al.  Control of postoperative pain , 1957 .

[19]  K. Austin,et al.  Multiple intramuscular injections: A major source of variability in analgesic response to meperidine , 1980, PAIN.

[20]  Y. P. Liu,et al.  Modeling and estimation for patient controlled analgesia of chronic pain , 1995, IEEE Trans. Biomed. Eng..

[21]  J Bacon-Shone,et al.  Use of two oximeters to investigate a method of movement artefact rejection using photoplethysmographic signals. , 1994, British journal of anaesthesia.

[22]  L E Mather,et al.  Variables of patient‐controlled analgesia 1. bolus size , 1989, Anaesthesia.

[23]  P. White,et al.  Is the risk of using a "basal" infusion with patient-controlled analgesia therapy justified? , 1992, Anesthesiology.

[24]  Bertil Hök,et al.  Post-anesthesia monitoring: More than 75% of pulse oximeter alarms are trivial , 1992 .

[25]  Richard M. Marks,et al.  Undertreatment of Medical Inpatients with Narcotic Analgesics , 1973 .

[26]  Frances V. Abbott,et al.  Reduction of Postoperative Morbidity Following Patient-Controlled Morphine , 1991 .

[27]  L E Mather,et al.  Patient-controlled analgesia. Pharmacokinetic and therapeutic considerations. , 1993, Clinical pharmacokinetics.

[28]  Harry Owen,et al.  Variable‐dose patient‐controlled analgesia , 1995, Anaesthesia.

[29]  R. Jacobson,et al.  A Computer-Based System for Controlling Plasma Opioid Concentration According to Patient Need for Analgesia , 1991, Clinical pharmacokinetics.

[30]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[31]  O. L. R. Jacobs,et al.  Modelling estimation and control in the relief of post-operative pain , 1985, Autom..