Image analysis techniques for automated IVUS contour detection.
暂无分享,去创建一个
Ioannis Kompatsiaris | Vasileios Mezaris | Maria Papadogiorgaki | Yiannis S Chatzizisis | George D Giannoglou | V. Mezaris | I. Kompatsiaris | Y. Chatzizisis | G. Giannoglou | M. Papadogiorgaki
[1] E. Edelman,et al. Prediction of the Localization of High-Risk Coronary Atherosclerotic Plaques on the Basis of Low Endothelial Shear Stress: An Intravascular Ultrasound and Histopathology Natural History Study , 2008, Circulation.
[2] G Kovalski,et al. Three-dimensional automatic quantitative analysis of intravascular ultrasound images. , 2000, Ultrasound in medicine & biology.
[3] Michael G. Strintzis,et al. Deformable boundary detection of stents in angiographic images , 2000, IEEE Transactions on Medical Imaging.
[4] Michael Unser,et al. Texture classification and segmentation using wavelet frames , 1995, IEEE Trans. Image Process..
[5] Tomoyuki Yambe,et al. An adaptive fuzzy segmentation of intravascular ultrasound images , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).
[6] A. Wahle,et al. Effect of Endothelial Shear Stress on the Progression of Coronary Artery Disease, Vascular Remodeling, and In-Stent Restenosis in Humans: In Vivo 6-Month Follow-Up Study , 2003, Circulation.
[7] Hui Zhu,et al. IVUS image segmentation based on contrast , 2002, SPIE Medical Imaging.
[8] P. Serruys,et al. True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation. , 2000, Circulation.
[9] D. Vince,et al. Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images , 2000, IEEE Transactions on Medical Imaging.
[10] Tong Fang,et al. Shape-Driven Segmentation of the Arterial Wall in Intravascular Ultrasound Images , 2008, IEEE Transactions on Information Technology in Biomedicine.
[11] Milan Sonka,et al. Segmentation of intravascular ultrasound images: a knowledge-based approach , 1995, IEEE Trans. Medical Imaging.
[12] Richard K. Beatson,et al. Reconstruction and representation of 3D objects with radial basis functions , 2001, SIGGRAPH.
[13] Michael G. Strintzis,et al. Still Image Segmentation Tools For Object-Based Multimedia Applications , 2004, Int. J. Pattern Recognit. Artif. Intell..
[14] Petia Radeva,et al. Statistical strategy for anisotropic adventitia modelling in IVUS , 2006, IEEE Transactions on Medical Imaging.
[15] H. Ermert,et al. Computerized segmentation of blood and luminal borders in intravascular ultrasound , 2004, IEEE Ultrasonics Symposium, 2004.
[16] Theodore Johnson,et al. Semi-automated boundary detection for intravascular ultrasound , 1992, Proceedings Computers in Cardiology.
[17] P. Serruys,et al. Evaluation of endothelial shear stress and 3D geometry as factors determining the development of atherosclerosis and remodeling in human coronary arteries in vivo. Combining 3D reconstruction from angiography and IVUS (ANGUS) with computational fluid dynamics. , 1997, Arteriosclerosis, thrombosis, and vascular biology.
[18] J.D. Klingensmith,et al. Segmentation of three-dimensional intravascular ultrasound images using spectral analysis and a dual active surface model , 2004, IEEE Ultrasonics Symposium, 2004.
[19] E. Edelman,et al. Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior. , 2007, Journal of the American College of Cardiology.
[20] Michael G. Strintzis,et al. A novel active contour model for fully automated segmentation of intravascular ultrasound images: In vivo validation in human coronary arteries , 2007, Comput. Biol. Medicine.
[21] Jean Meunier,et al. Intravascular Ultrasound Image Segmentation: A Fast-Marching Method , 2003, MICCAI.
[22] Yuanyuan Wang,et al. Estimating coronary artery lumen area with optimization-based contour detection , 2003, IEEE Transactions on Medical Imaging.
[23] Milan Sonka,et al. Reproducibility of coronary lumen, plaque, and vessel wall reconstruction and of endothelial shear stress measurements in vivo in humans , 2003, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.
[24] Dimitrios I. Fotiadis,et al. An automated method for lumen and media-adventitia border detection in a sequence of IVUS frames , 2004, IEEE Transactions on Information Technology in Biomedicine.
[25] Y. Saijo,et al. Detection of Luminal Contour Using Fuzzy Clustering and Mathematical Morphology in Intravascular Ultrasound Images , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.
[26] Frits Mastik,et al. Fully automatic luminal contour segmentation in intracoronary ultrasound imaging-a statistical approach , 2004, IEEE Transactions on Medical Imaging.
[27] N. Maglaveras,et al. Integration of multi-modality imaging for accurate 3D reconstruction of human coronary arteries in vivo , 2006 .
[28] G. Slabaugh,et al. Shape-driven Segmentation of Intravascular Ultrasound Images , 2006 .
[29] Timothy F. Cootes,et al. Assessing the accuracy of non-rigid registration with and without ground truth , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..
[30] Yiannis S Chatzizisis,et al. In-vivo accuracy of geometrically correct three-dimensional reconstruction of human coronary arteries: is it influenced by certain parameters? , 2006, Coronary artery disease.
[31] V. Mezaris,et al. A Fully Automated Texture-based Approach for the Segmentation of Sequential IVUS Images , 2006 .
[32] E. Edelman,et al. Risk stratification of individual coronary lesions using local endothelial shear stress: a new paradigm for managing coronary artery disease , 2007, Current opinion in cardiology.
[33] N. Maglaveras,et al. In-vivo validation of spatially correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane angiography , 2006, Coronary artery disease.
[34] Michael G. Strintzis,et al. An Automated Model for Rapid and Reliable Segmentation of Intravascular Ultrasound Images , 2006, ISBMDA.