Application of the Moving-Actuator Type Pump as a Ventricular Assist Device: In vitro and in Vivo Studies

A moving actuator type pump has been developed as a multifunctional Korean artificial heart (AnyHeart™). The pump consists of a moving actuator as an energy converter, right and left sacs, polymer (or mechanical) valves, and a rigid polyurethane housing. The actuator containing a brushless DC motor moves back and forth on an epicyclical gear train to produce a pendular motion, which compresses both sacs alternately. Of its versatile functions of ventricular assist device and total artificial heart use, we have evaluated the system performance as a single or biventricular assist device through in vitro and in vivo experiments. Pump performance and anatomical feasibility were tested using various animals of different sizes. In the case of single ventricular assist device (VAD) use, one of the sacs remained empty and a mini-compliance chamber was attached to either an outflow or inflow port of the unused sac. The in vitro and in vivo studies show acceptable performance and pump behavior. Further extensive study is required to proceed to human application.

[1]  B G Min,et al.  A New Automatic Cardiac Output Control Algorithm for Moving Actuator Total Artificial Heart by Motor Current Waveform Analysis , 1996, The International journal of artificial organs.

[2]  S Takatani,et al.  In vitro and in vivo validation tests for total artificial heart. , 1994, Artificial organs.

[3]  A. Snyder,et al.  Current status of permanent total artificial hearts. , 1989, The Annals of thoracic surgery.

[4]  Robert T. V. Kung,et al.  Self-regulation of an electrohydraulic total artificial heart , 1991 .

[5]  R Kiraly,et al.  The Cleveland Clinic-Nimbus total artificial heart. Design and in vitro function. , 1994, The Journal of thoracic and cardiovascular surgery.

[6]  G. Ryu,et al.  A moving-actuator type electromechanical total artificial heart. II. Circular type and animal experiment , 1990, IEEE Transactions on Biomedical Engineering.

[7]  B P Griffith,et al.  Surgical positioning of the Jarvik-7 artificial heart. , 1986, The Journal of heart transplantation.

[8]  G. Rosenberg,et al.  Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart. , 1978, Transactions - American Society for Artificial Internal Organs.

[9]  Byoung Goo Min,et al.  Automatic Control Algorithm for Cardiac Output Regulation of the Total Artificial Heart (TAH) , 1996 .

[10]  D. Genecov,et al.  Effect of synchronous and asynchronous pulsatile flow during left, right, and biventricular bypass. , 1991, ASAIO transactions.

[11]  B. Min,et al.  A moving-actuator type electromechanical total artificial heart. I. Linear type and mock circulation experiments , 1990, IEEE Transactions on Biomedical Engineering.

[12]  P M Portner,et al.  In vitro and in vivo testing of a totally implantable left ventricular assist system. , 1988, ASAIO transactions.