Occupational eye dose in interventional cardiology procedures

It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRISTM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R2 = 0.93 and R2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.

[1]  J. Valentin,et al.  Avoidance of radiation injuries from medical interventional procedures. , 2000, Annals of the ICRP.

[2]  K. Chida,et al.  Clarifying and visualizing sources of staff-received scattered radiation in interventional procedures. , 2011, AJR. American journal of roentgenology.

[3]  H. Nishida,et al.  Guidelines for elective percutaneous coronary intervention in patients with stable coronary artery disease (JCS 2011) published in 2012--digest version. , 2013, Circulation journal : official journal of the Japanese Circulation Society.

[4]  C. Martin,et al.  Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staff , 2013, Journal of radiological protection : official journal of the Society for Radiological Protection.

[5]  Masayuki Zuguchi,et al.  Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures. , 2008, Radiation protection dosimetry.

[6]  Donald L. Miller,et al.  Patient skin reactions from interventional fluoroscopy procedures. , 2014, AJR. American journal of roentgenology.

[7]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[8]  J H Hendry,et al.  ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection Context , 2012, Annals of the ICRP.

[9]  L. Dauer,et al.  Fears, feelings, and facts: interactively communicating benefits and risks of medical radiation with patients. , 2011, AJR. American journal of roentgenology.

[10]  B Geiger,et al.  ICRP Publication 120: Radiological Protection in Cardiology , 2013, Annals of the ICRP.

[11]  J. Valentin,et al.  Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85 , 2000 .

[12]  G. O'reilly,et al.  Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. , 2013, The British journal of radiology.

[13]  Masayuki Zuguchi,et al.  A cross‐sectional study of the radiation dose and image quality of X‐ray equipment used in IVR , 2016, Journal of applied clinical medical physics.

[14]  Masayuki Zuguchi,et al.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. , 2006, AJR. American journal of roentgenology.

[15]  Masayuki Zuguchi,et al.  Real-time patient radiation dosimeter for use in interventional radiology. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[16]  Masayuki Zuguchi,et al.  Occupational dose in interventional radiology procedures. , 2013, AJR. American journal of roentgenology.

[17]  C. Clement,et al.  Radiological protection in cardiology , 2012 .

[18]  A. Carnicer,et al.  Oramed: optimization of radiation protection of medical staff , 2012 .

[19]  Y. Katahira,et al.  Evaluation of additional lead shielding in protecting the physician from radiation during cardiac interventional procedures. , 2005, Nihon Hoshasen Gijutsu Gakkai zasshi.

[20]  J Farah,et al.  Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses , 2014, Journal of radiological protection : official journal of the Society for Radiological Protection.

[21]  Icrp ICRP Publication 120: Radiological Protection in Cardiology , 2013 .

[22]  G. Gualdrini,et al.  Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project , 2011 .

[23]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[24]  E. Carinou IAEA Tec Doc-1731 'Implications for Occupational Radiation Protection of the New Dose Limit for the Lens of the Eye'. , 2016, Radiation protection dosimetry.

[25]  M Ginjaume,et al.  FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS. , 2016, Radiation protection dosimetry.

[26]  Meiping Huang,et al.  Operator Radiation and the Efficacy of Ceiling-Suspended Lead Screen Shielding during Coronary Angiography: An Anthropomorphic Phantom Study Using Real-Time Dosimeters , 2017, Scientific Reports.

[27]  S. Takahashi,et al.  Effect of radiation monitoring method and formula differences on estimated physician dose during percutaneous coronary intervention , 2009, Acta radiologica.

[28]  T. Ishibashi,et al.  Radiation dose and radiation protection for patients and physicians during interventional procedure. , 2010, Journal of radiation research.

[29]  Koichi Chida,et al.  The necessity of follow-up for radiation skin injuries in patients after percutaneous coronary interventions: radiation skin injuries will often be overlooked clinically , 2012, Acta radiologica.

[30]  E P Efstathopoulos,et al.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures. , 2011, The British journal of radiology.

[31]  Masayuki Zuguchi,et al.  Radiation dose of interventional radiology system using a flat-panel detector. , 2009, AJR. American journal of roentgenology.

[32]  F. Vanhaverea,et al.  Measurements of eye lens doses in interventional radiology and cardiology : Final results of the ORAMED project , 2022 .