Design of well and groove microchannel bioreactors for cell culture

Microfluidic bioreactors have been shown valuable for various cellular applications. The use of micro‐wells/grooves bioreactors, in which micro‐topographical features are used to protect sensitive cells from the detrimental effects of fluidic shear stress, is a promising approach to culture sensitive cells in these perfusion microsystems. However, such devices exhibit substantially different fluid dynamics and mass transport characteristics compared to conventional planar microchannel reactors. In order to properly design and optimize these systems, fluid and mass transport issues playing a key role in microscale bioreactors should be adequately addressed. The present work is a parametric study of micro‐groove/micro‐well microchannel bioreactors. Operation conditions and design parameters were theoretically examined via a numerical model. The complex flow pattern obtained at grooves of various depths was studied and the shear protection factor compared to planar microchannels was evaluated. 3D flow simulations were preformed in order to examine the shear protection factor in micro‐wells, which were found to have similar attributes as the grooves. The oxygen mass transport problem, which is coupled to the fluid mechanics problem, was solved for various groove geometries and for several cell types, assuming a defined shear stress limitation. It is shown that by optimizing the groove depth, the groove bioreactor may be used to effectively maximize the number of cells cultured within it or to minimize the oxygen gradient existing in such devices. Moreover, for sensitive cells having a high oxygen demand (e.g., hepatocytes) or low endurance to shear (e.g., human embryonic stem cells), results show that the use of grooves is an enabling technology, since under the same physical conditions the cells cannot be cultured for long periods of time in a planar microchannel. In addition to the theoretical model findings, the culture of human foreskin fibroblasts in groove (30 µm depth) and well bioreactors (35 µm depth) was experimentally examined at various flow rates of medium perfusion and compared to cell culture in regular flat microchannels. It was shown that the wells and the grooves enable a one order of magnitude increase in the maximum perfusion rate compared to planar microchannels. Altogether, the study demonstrates that the proper design and use of microgroove/well bioreactors may be highly beneficial for cell culture assays. Biotechnol. Bioeng. 2009;102: 1222–1230. © 2008 Wiley Periodicals, Inc.

[1]  Uri Dinnar,et al.  A parametric study of human fibroblasts culture in a microchannel bioreactor. , 2007, Lab on a chip.

[2]  Ali Khademhosseini,et al.  Cell docking inside microwells within reversibly sealed microfluidic channels for fabricating multiphenotype cell arrays. , 2005, Lab on a chip.

[3]  J G Bender,et al.  Development of novel perfusion chamber to retain nonadherent cells and its use for comparison of human “mobilized” peripheral blood mononuclear cell cultures with and without irradiated bone marrow stroma , 2000, Biotechnology and bioengineering.

[4]  M. Toner,et al.  Microfabricated grooved substrates as platforms for bioartificial liver reactors. , 2005, Biotechnology and bioengineering.

[5]  M. Toner,et al.  Analysis of Oxygen Transport to Hepatocytes in a Flat-Plate Microchannel Bioreactor , 2001, Annals of Biomedical Engineering.

[6]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[7]  W M Miller,et al.  Transport in a Grooved Perfusion Flat‐Bed Bioreactor for Cell Therapy Applications , 1998, Biotechnology progress.

[8]  Peng Yu,et al.  Mass transport and shear stress in a microchannel bioreactor: numerical simulation and dynamic similarity. , 2006, Journal of biomechanical engineering.

[9]  Ali Khademhosseini,et al.  Microcirculation within grooved substrates regulates cell positioning and cell docking inside microfluidic channels. , 2008, Lab on a chip.

[10]  Mehmet Toner,et al.  Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates , 2008, Biotechnology and bioengineering.

[11]  Julio M. Ottino,et al.  Transport enhancement mechanisms in open cavities , 2002, Journal of Fluid Mechanics.

[12]  Douglas A Lauffenburger,et al.  Microfluidic shear devices for quantitative analysis of cell adhesion. , 2004, Analytical chemistry.

[13]  A. Khademhosseini,et al.  Microscale technologies for tissue engineering and biology. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Assaf Deutsch,et al.  A novel miniature cell retainer for correlative high-content analysis of individual untethered non-adherent cells. , 2006, Lab on a chip.

[15]  D. Beebe,et al.  Microenvironment design considerations for cellular scale studies. , 2004, Lab on a chip.

[16]  B Lepioufle,et al.  Study of osteoblastic cells in a microfluidic environment. , 2006, Biomaterials.

[17]  M. D. Deshpande,et al.  FLUID MECHANICS IN THE DRIVEN CAVITY , 2000 .

[18]  G. Ming,et al.  A microfluidics-based turning assay reveals complex growth cone responses to integrated gradients of substrate-bound ECM molecules and diffusible guidance cues. , 2008, Lab on a chip.

[19]  Numerical simulation on mass transport in a microchannel bioreactor for co-culture applications. , 2007, Journal of biomechanical engineering.

[20]  S. Bhatia,et al.  Formation of steady-state oxygen gradients in vitro: application to liver zonation. , 2003, Biotechnology and bioengineering.

[21]  Ali Khademhosseini,et al.  A microwell array system for stem cell culture. , 2008, Biomaterials.

[22]  S. Bhatia,et al.  In vitro zonation and toxicity in a hepatocyte bioreactor. , 2005, Toxicological sciences : an official journal of the Society of Toxicology.

[23]  Jennifer J Linderman,et al.  Model‐based analysis and design of a microchannel reactor for tissue engineering , 2006, Biotechnology and bioengineering.

[24]  Shuichi Takayama,et al.  Quantitative measurement and control of oxygen levels in microfluidic poly(dimethylsiloxane) bioreactors during cell culture , 2007, Biomedical microdevices.