3-D segmentation and quantitative analysis of inner and outer walls of thrombotic abdominal aortic aneurysms

An abdominal aortic aneurysm (AAA) is an area of a localized widening of the abdominal aorta, with a frequent presence of thrombus. A ruptured aneurysm can cause death due to severe internal bleeding. AAA thrombus segmentation and quantitative analysis are of paramount importance for diagnosis, risk assessment, and determination of treatment options. Until now, only a small number of methods for thrombus segmentation and analysis have been presented in the literature, either requiring substantial user interaction or exhibiting insufficient performance. We report a novel method offering minimal user interaction and high accuracy. Our thrombus segmentation method is composed of an initial automated luminal surface segmentation, followed by a cost function-based optimal segmentation of the inner and outer surfaces of the aortic wall. The approach utilizes the power and flexibility of the optimal triangle mesh-based 3-D graph search method, in which cost functions for thrombus inner and outer surfaces are based on gradient magnitudes. Sometimes local failures caused by image ambiguity occur, in which case several control points are used to guide the computer segmentation without the need to trace borders manually. Our method was tested in 9 MDCT image datasets (951 image slices). With the exception of a case in which the thrombus was highly eccentric, visually acceptable aortic lumen and thrombus segmentation results were achieved. No user interaction was used in 3 out of 8 datasets, and 7.80 ± 2.71 mouse clicks per case / 0.083 ± 0.035 mouse clicks per image slice were required in the remaining 5 datasets.

[1]  Sven Loncaric,et al.  3-D deformable model for abdominal aortic aneurysm segmentation from CT images , 2000, IWISPA 2000. Proceedings of the First International Workshop on Image and Signal Processing and Analysis. in conjunction with 22nd International Conference on Information Technology Interfaces. (IEEE.

[2]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Max A. Viergever,et al.  Interactive segmentation of abdominal aortic aneurysms in CTA images , 2004, Medical Image Anal..

[4]  Attila Kuba,et al.  A Sequential 3D Thinning Algorithm and Its Medical Applications , 2001, IPMI.

[5]  Timothy F. Cootes,et al.  The Use of Active Shape Models for Locating Structures in Medical Images , 1993, IPMI.

[6]  Xiaodong Wu,et al.  Optimal Net Surface Problems with Applications , 2002, ICALP.

[7]  Marcel Breeuwer,et al.  Segmentation of Abdominal Aortic Aneurysms with a Non-parametric Appearance Model , 2004, ECCV Workshops CVAMIA and MMBIA.

[8]  D. Chen,et al.  Globally optimal segmentation of interacting surfaces with geometric constraints , 2004, CVPR 2004.

[9]  Xiaodong Wu,et al.  Efficient optimal surface detection: theory, implementation, and experimental validation , 2004, SPIE Medical Imaging.

[10]  Sven Loncaric,et al.  3D image analysis of abdominal aortic aneurysm , 2002, SPIE Medical Imaging.

[11]  Dorin Comaniciu,et al.  Vessel detection by mean shift based ray propagation , 2001, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 2001).

[12]  Scott T. Acton,et al.  Speckle reducing anisotropic diffusion , 2002, IEEE Trans. Image Process..

[13]  Xiaodong Wu,et al.  Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic Approach , 2006, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[14]  Max A. Viergever,et al.  Active-shape-model-based segmentation of abdominal aortic aneurysms in CTA images , 2002, SPIE Medical Imaging.

[15]  Marcel Breeuwer,et al.  Segmentation of thrombus in abdominal aortic aneurysms from CTA with nonparametric statistical grey level appearance modeling , 2005, IEEE Transactions on Medical Imaging.

[16]  Max A. Viergever,et al.  Semiautomatic aortic endograft localization for postoperative evaluation of endovascular aneurysm treatment , 2001, SPIE Medical Imaging.