A novel approach to the simultaneous extraction and non-targeted analysis of the small molecules metabolome and lipidome using 96-well solid phase extraction plates with column-switching technology.

This study combines solid phase extraction (SPE) using 96-well plates with column-switching technology to construct a rapid and high-throughput method for the simultaneous extraction and non-targeted analysis of small molecules metabolome and lipidome based on ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry. This study first investigated the columns and analytical conditions for small molecules metabolome and lipidome, separated by an HSS T3 and BEH C18 columns, respectively. Next, the loading capacity and actuation duration of SPE were further optimized. Subsequently, SPE and column switching were used together to rapidly and comprehensively analyze the biological samples. The experimental results showed that the new analytical procedure had good precision and maintained sample stability (RSD<15%). The method was then satisfactorily applied to more widely analyze the small molecules metabolome and lipidome to test the throughput. The resulting method represents a new analytical approach for biological samples, and a highly useful tool for researches in metabolomics and lipidomics.

[1]  D. Kwon,et al.  Obesity-Related Metabolomic Analysis of Human Subjects in Black Soybean Peptide Intervention Study by Ultraperformance Liquid Chromatography and Quadrupole-Time-of-Flight Mass Spectrometry , 2013, Journal of obesity.

[2]  P. Solich,et al.  New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography. , 2014, Talanta.

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  Xi-jun Wang,et al.  Metabolomics in diagnosis and biomarker discovery of colorectal cancer. , 2014, Cancer letters.

[5]  P. Arora Metabolomics yield a novel biomarker for predicting diabetes mellitus risk in humans. , 2014, Circulation. Cardiovascular genetics.

[6]  A. Kotani,et al.  Three-channel column-switching high-performance liquid chromatography with electrochemical detection for determining bioactive redox components in Salvia miltiorrhiza. , 2012, Journal of chromatography. A.

[7]  N. Vaziri,et al.  Title Plasma lipidomics reveal profound perturbation of glycerophospholipids , fatty acids , and sphingolipids in diet-induced hyperlipidemia , 2015 .

[8]  B. Hammock,et al.  Mass spectrometry-based metabolomics. , 2007, Mass spectrometry reviews.

[9]  Luzimar Gonzaga Fernandez,et al.  Lipidomics in the study of lipid metabolism: Current perspectives in the omic sciences. , 2015, Gene.

[10]  L. Lind,et al.  A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry. , 2013, Journal of chromatography. A.

[11]  Zhongping Huang,et al.  Simultaneous determination of glucose, D-gluconic, 2-keto-D-gluconic and 5-keto-D-gluconic acids by ion chromatography-pulsed amperometric detection with column-switching technique. , 2013, Talanta.

[12]  M. Urpi-Sardà,et al.  Comparative analysis of sample preparation methods to handle the complexity of the blood fluid metabolome: when less is more. , 2013, Analytical chemistry.

[13]  P. Solich,et al.  A rapid HPLC column switching method for sample preparation and determination of β-carotene in food supplements. , 2013, Food chemistry.

[14]  F. Gonzalez,et al.  LC–MS-based metabolomics: an update , 2014, Archives of Toxicology.

[15]  J. Ayling,et al.  Differential coulometric oxidation following post column-switching high pressure liquid chromatography for fluorescence measurement of unmetabolized folic acid in human plasma. , 2013, Journal of chromatography. A.

[16]  S. Gatzek,et al.  Controlled protein precipitation in combination with chip-based nanospray infusion mass spectrometry. An approach for metabolomics profiling of plasma. , 2005, Analytical chemistry.

[17]  D. Wishart,et al.  Standardizing the experimental conditions for using urine in NMR-based metabolomic studies with a particular focus on diagnostic studies: a review , 2014, Metabolomics.

[18]  M. Armstrong,et al.  New sample preparation approach for mass spectrometry-based profiling of plasma results in improved coverage of metabolome. , 2013, Journal of chromatography. A.

[19]  Yubo Li,et al.  Metabonomics study on nephrotoxicity induced by intraperitoneal and intravenous cisplatin administration using rapid resolution liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry (RRLC-Q-TOF-MS) , 2014 .

[20]  Gabriele Cruciani,et al.  LC/MS lipid profiling from human serum: a new method for global lipid extraction , 2014, Analytical and Bioanalytical Chemistry.

[21]  Donald G Robertson,et al.  Metabolomics in toxicology: preclinical and clinical applications. , 2011, Toxicological sciences : an official journal of the Society of Toxicology.