Effect of Variations in Basal Plasma Glucose Concentration on Glucose Utilization (M) and Metabolic Clearance (MCR) Rates During Insulin Clamp Studies in Patients with Non-insulin-dependent Diabetes Mellitus

Two insulin clamp studies were performed at different steady-state plasma glucose concentrations in 13 patients with non-insulin-dependent diabetes mellitus (NIDDM). Steady-state plasma insulin concentrations were comparable, with mean ± SEM levels of 94 ± 3 and 95 ± 4 μU/ml being achieved during the two studies. Glucose utilization rate (M) varied directly with plasma glucose concentration in each subject. Thus, the mean ± SEM value of M was 4.92 ± 0.73 mg/kg/min when patients were studied at a mean ± SEM plasma glucose concentration of 226 ± 15 mg/dl, and M was 2.71 mg/kg/min when the same subjects were studied at a glucose concentration of 118 ± 6 mg/dl. In contrast, the values for glucose metabolic clearance rate (MCR), which were 2.35 ± 0.50 and 2.49 ± 0.47 ml/kg/min, respectively, during the two studies, did not vary significantly with plasma glucose concentration. These data indicate that the glucose metabolic clearance rate (MCR), but not glucose utilization rate (M), can be used to compare in vivo insulin action when insulin clamp studies are performed in subjects with different basal plasma glucose concentrations.

[1]  G. Reaven,et al.  Relationship Between Fasting Plasma Insulin Level and Resistance to Insulin-Mediated Glucose Uptake in Normal and Diabetic Subjects , 1973, Diabetes.

[2]  G. Reaven,et al.  Enhanced Glucose Utilization During Prolonged Glucose Clamp Studies , 1981, Diabetes.

[3]  G. Reaven,et al.  Assessment of Insulin Resistance with the Insulin Suppression Test and the Euglycemic Clamp , 1981, Diabetes.

[4]  P. Alto,et al.  Locating the Site(s) of Insulin Resistance in Patients with Nonketotic Diabetes Mellitus , 1976, Diabetes.

[5]  R. Rizza,et al.  Effects of Plasma Glucose Concentration on Glucose Utilization and Glucose Clearance in Normal Man , 1981, Diabetes.

[6]  J D Best,et al.  Glucose Disposal is Not Proportional to Plasma Glucose Level in Man , 1981, Diabetes.

[7]  G. Reaven,et al.  Defect in Glucose Removal in Nonketotlc Diabetic Patients with Fasting Hyperglycemia , 1978, Diabetes.

[8]  M S Harris,et al.  Relationship between the plasma glucose level and glucose uptake in the conscious dog. , 1978, Metabolism: clinical and experimental.

[9]  J. Sternberg,et al.  A New and Rapid Method for the Determination of Glucose by Measurement of Rate of Oxygen Consumption , 1968 .

[10]  R. Steele,et al.  INFLUENCES OF GLUCOSE LOADING AND OF INJECTED INSULIN ON HEPATIC GLUCOSE OUTPUT * , 1959, Annals of the New York Academy of Sciences.

[11]  R. DeFronzo,et al.  Stimulation of Counterregulatory Hormonal Responses in Diabetic Man by a Fall in Glucose Concentration , 1980, Diabetes.

[12]  R. DeFronzo,et al.  Glucose clamp technique: a method for quantifying insulin secretion and resistance. , 1979, The American journal of physiology.