High-energy X-ray diffraction using the Pixium 4700 flat-panel detector.

The Pixium 4700 detector represents a significant step forward in detector technology for high-energy X-ray diffraction. The detector design is based on digital flat-panel technology, combining an amorphous Si panel with a CsI scintillator. The detector has a useful pixel array of 1910 x 2480 pixels with a pixel size of 154 microm x 154 microm, and thus it covers an effective area of 294 mm x 379 mm. Designed for medical imaging, the detector has good efficiency at high X-ray energies. Furthermore, it is capable of acquiring sequences of images at 7.5 frames per second in full image mode, and up to 60 frames per second in binned region of interest modes. Here, the basic properties of this detector applied to high-energy X-ray diffraction are presented. Quantitative comparisons with a widespread high-energy detector, the MAR345 image plate scanner, are shown. Other properties of the Pixium 4700 detector, including a narrow point-spread function and distortion-free image, allows for the acquisition of high-quality diffraction data at high X-ray energies. In addition, high frame rates and shutterless operation open new experimental possibilities. Also provided are the necessary data for the correction of images collected using the Pixium 4700 for diffraction purposes.

[1]  J. Daniels Determination of directionally dependent structural and microstructural information using high-energy X-ray diffraction , 2008 .

[2]  Jacob L. Jones,et al.  High-throughput evaluation of domain switching in piezoelectric ceramics and application to PbZr0.6Ti0.4O3 doped with La and Fe , 2008 .

[3]  E. Eikenberry,et al.  Charge-coupled device area x-ray detectors , 2002 .

[4]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[5]  Philip J. Withers,et al.  Mapping two-dimensional state of strain using synchroton X-ray diffraction , 1998 .

[6]  R. Kampmann,et al.  Internal stress measurements by high-energy synchrotron X-ray diffraction at increased specimen-detector distance , 2003 .

[7]  U. Lienert,et al.  Characterization and application of a GE amorphous silicon flat panel detector in a synchrotron light source , 2007 .

[8]  A. P. Hammersley,et al.  Two-dimensional detector software: From real detector to idealised image or two-theta scan , 1996 .

[9]  D. Dunand,et al.  Synchrotron X-ray study of bulk lattice strains in externally loaded Cu-Mo composites , 2000 .

[10]  Simon J. L. Billinge,et al.  Underneath the Bragg Peaks: Structural Analysis of Complex Materials , 2003 .

[11]  K. Chapman,et al.  Applications of an amorphous silicon-based area detector for high-resolution, high-sensitivity and fast time-resolved pair distribution function measurements , 2007 .

[12]  P. Withers,et al.  A synchrotron radiation study of transient internal strain changes during the early stages of thermal cycling in an Al / SiCw MMC , 1996 .

[13]  J. Hanson,et al.  Rapid acquisition pair distribution function (RA-PDF) analysis. , 2003, cond-mat/0304638.