Performance investigation and economic benefits of new control strategies for heat pump-gas fired water heater hybrid system

Abstract More recently, the hybrid system equipped with the combination of heat pump and gas fired water heater in one device is increasingly attracting people’s attention from both the industry and academia. In this study, the hybrid system with two control strategies is presented as the alternative option for domestic hot water supply and space heating with the aim of revealing its economic benefits. For the control strategy I, the two heating sources, i.e. heat pump and gas heater, can be switched and there are only two modes: heat pump mode, and gas heater mode. While for the control strategy II, the two heating sources could be handled with the proper arrangement for the loading share. There are 3 modes under this control strategy: heat pump mode, hybrid mode, and gas heater mode. The auxiliary resistance heater is used for heat pump mode if necessary, not for the hybrid mode. Various climate conditions, water initial temperature and final temperature are investigated for the hybrid system, and different heating supply forms are compared. Regarding the domestic hot water demand of 70 L per apartment per day, the gas heater can lead to a ∼38% operation energy cost saving from electric heater, and both of the two control strategies with hybrid system can result in a ∼20% to ∼65% more operation energy cost reduction than gas heater under climate condition of −5 °C to 20 °C, with a more pronounced reduction towards hot climates. Control strategy II, as the most cost-efficient option, can achieve a ∼10% to ∼23% more energy cost saving than strategy I, especially under climate condition of 0 °C to −12 °C. In the hybrid mode with strategy II, a decrease of the final temperature, results in a better economic merit. Regarding the hourly under-flooring heating case, the control strategy II, as the best option, can lead to a ∼6% to ∼70% more hourly process energy cost saving compared with the gas heater from −15 °C to 20 °C ambient conditions. During the typical heating season with ambient (−15 °C to 7 °C), the lowest process energy cost can be achieved by control strategy II. In the same external conditions, the under-flooring heating application has a lower system operation energy process cost than the indoor radiator heating case.

[1]  Kaamran Raahemifar,et al.  Effects of intelligent strategy planning models on residential HVAC system energy demand and cost during the heating and cooling seasons , 2017 .

[2]  Gian Luca Morini,et al.  Sizing effects on the energy performance of reversible air-source heat pumps for office buildings , 2017 .

[3]  Frédéric Magoulès,et al.  A review on the prediction of building energy consumption , 2012 .

[4]  Dawei Tang,et al.  Investigation on the thermal performance and optimization of a heat pump water heater assisted by shower waste water , 2013 .

[5]  M. Santamouris,et al.  On the impact of urban climate on the energy consumption of buildings , 2001 .

[6]  Alan S. Fung,et al.  Performance of two-stage variable capacity air source heat pump: Field performance results and TRNSYS simulation , 2015 .

[7]  Zhihua Zhou,et al.  Phase change materials for solar thermal energy storage in residential buildings in cold climate , 2015 .

[8]  Guozhong Zheng,et al.  Optimal operation strategy of the hybrid heating system composed of centrifugal heat pumps and gas boilers , 2013 .

[9]  Alan S. Fung,et al.  Performance characterization of an indoor air source heat pump water heater for residential applications in Canada , 2018 .

[10]  Qunli Zhang,et al.  Techno-economic analysis of air source heat pump applied for space heating in northern China , 2017 .

[11]  Shiming Deng,et al.  Energy transfer procession in an air source heat pump unit during defrosting , 2017 .

[12]  Ali Hakkaki-Fard,et al.  Improving cold climate air-source heat pump performance with refrigerant mixtures☆ , 2015 .

[13]  Weijun Gao,et al.  Demand response of customers in Kitakyushu smart community project to critical peak pricing of electricity , 2018, Energy and Buildings.

[14]  Wei Wang,et al.  Characteristics of an air source heat pump with novel photoelectric sensors during periodic frost–defrost cycles , 2013 .

[15]  Rakesh Kumar,et al.  Experimental and simulation studies on air source heat pump water heater for year-round applications in Canada , 2018 .

[16]  Guangcai Gong,et al.  Experimental investigation on an air source heat pump unit with a three-circuit outdoor coil for its reverse cycle defrosting termination temperature , 2017 .

[17]  Reinhard Radermacher,et al.  Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles , 2010 .

[18]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[19]  Min-Soo Kim,et al.  Thermodynamic analysis of optimal intermediate temperatures in R134a–R410A cascade refrigeration systems and its experimental verification , 2013 .

[20]  Dirk Müller,et al.  Numerical study on hybrid heat pump systems in existing buildings , 2014 .

[21]  M. A. Rafe Biswas,et al.  Regression analysis for prediction of residential energy consumption , 2015 .