A biochip reader using super critical angle fluorescence

Abstract We present fluorescence chip reader for rapid, multiplexed assay measurements on plastic biochips. The system is designed as a low-cost, compact and robust instrument for point of care testing. Fluorescence imaging of biochip arrays is accomplished with a custom designed piezo-motor-driven scanning stage coupled to an optical element based on supercritical angle fluorescence (SAF). The use of SAF not only provides substantial enhancement of the fluorescence collection efficiency but also confines the fluorescence detection volume strictly to the close proximity of the biochip surface, thereby discriminating against fluorescence background from the analyte solution. The high imaging resolution of the SAF scanner is demonstrated by measuring the point spread function of 200 nm fluorescence beads. The sensitivity of the system is determined by measuring an array of low fluorophore concentrations and by real-time monitoring of a model bioassay.

[1]  D. Toomre,et al.  Lighting up the cell surface with evanescent wave microscopy. , 2001, Trends in cell biology.

[2]  D. Axelrod Cell-substrate contacts illuminated by total internal reflection fluorescence , 1981, The Journal of cell biology.

[3]  J. Enderlein,et al.  Highly efficient optical detection of surface-generated fluorescence , 1999 .

[4]  Bo Liedberg,et al.  Silane-dextran chemistry on lateral flow polymer chips for immunoassays. , 2008, Lab on a chip.

[5]  F. Ligler,et al.  Evanescent wave fluorescence biosensors. , 2005, Biosensors & bioelectronics.

[6]  Ruckstuhl,et al.  Forbidden light detection from single molecules , 2000, Analytical chemistry.

[7]  B. MacCraith,et al.  Theory of the radiation of dipoles placed within a multilayer system. , 2000, Applied optics.

[8]  Cardinal Warde,et al.  Anisotropic scattering in photorefractive crystals , 1986 .

[9]  D. Axelrod,et al.  Fluorescence emission at dielectric and metal-film interfaces , 1987 .

[10]  W. Lukosz,et al.  Light emission by magnetic and electric dipoles close to a plane interface. I. Total radiated power , 1977 .

[11]  Jian-hui Jiang,et al.  Preparation of Near‐IR Fluorescent Nanoparticles for Fluorescence‐Anisotropy‐Based Immunoagglutination Assay in Whole Blood , 2006 .

[12]  D. Axelrod Total internal reflection fluorescence microscopy in cell biology. , 2003, Methods in enzymology.

[13]  S. Seeger,et al.  Parallel two-channel near- and far-field fluorescence microscopy. , 2007, Journal of biomedical optics.

[14]  Stefan Seeger,et al.  Highly sensitive biosensing using a supercritical angle fluorescence (SAF) instrument. , 2003, Biosensors & bioelectronics.

[15]  W. Lukosz,et al.  Light emission by magnetic and electric dipoles close to a plane dielectric interface. II. Radiation patterns of perpendicular oriented dipoles , 1977 .

[16]  B. MacCraith,et al.  Optimization of plasmonic enhancement of fluorescence on plastic substrates. , 2008, Langmuir : the ACS journal of surfaces and colloids.

[17]  Stefan Seeger,et al.  Confocal reader for biochip screening and fluorescence microscopy. , 2005, Biosensors & bioelectronics.