A foot drop compensation device based on surface multi-field functional electrical stimulation—Usability study in a clinical environment

Introduction Functional electrical stimulation applies electrical pulses to the peripheral nerves to artificially achieve a sensory/motor function. When applied for the compensation of foot drop it provides both assistive and therapeutic effects. Multi-field electrodes have shown great potential but may increase the complexity of these systems. Usability aspects should be checked to ensure their success in clinical environments. Methods We developed the Fesia Walk device, based on a surface multi-field electrode and an automatic calibration algorithm, and carried out a usability study to check the feasibility of integrating this device in therapeutic programs in clinical environments. The study included 4 therapists and 10 acquired brain injury subjects (8 stroke and 2 traumatic brain injury). Results Therapists and users were “very satisfied” with the device according to the Quebec User Evaluation of Satisfaction with Assistive Technology scale, with average scores of 4.1 and 4.2 out of 5, respectively. Therapists considered the Fesia Walk device as “excellent” according to the System Usability Scale with an average score of 85.6 out of 100. Conclusions This study showed us that it is feasible to include surface multi-field technology while keeping a device simple and intuitive for successful integration in common neurorehabilitation programs.

[1]  Yoichi Shimada,et al.  Effect of electrical stimulation therapy on upper extremity functional recovery and cerebral cortical changes in patients with chronic hemiplegia. , 2012, Biomedical research.

[2]  Manjunatha Mahadevappa,et al.  Functional electrical stimulation of dorsiflexor muscle: effects on dorsiflexor strength, plantarflexor spasticity, and motor recovery in stroke patients. , 2011, NeuroRehabilitation.

[3]  Philip T. Kortum,et al.  Determining what individual SUS scores mean: adding an adjective rating scale , 2009 .

[4]  David Howard,et al.  Feasibility study of a take-home array-based functional electrical stimulation system with automated setup for current functional electrical stimulation users with foot-drop. , 2014, Archives of physical medicine and rehabilitation.

[5]  M. Popovic,et al.  Automatic determination of the optimal shape of a surface electrode: Selective stimulation , 2009, Journal of Neuroscience Methods.

[6]  D. Moore,et al.  Effectiveness of upper limb functional electrical stimulation after stroke for the improvement of activities of daily living and motor function: a systematic review and meta-analysis , 2017, Systematic Reviews.

[7]  Dejan B Popović,et al.  Advances in functional electrical stimulation (FES). , 2014, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[8]  Chris Freeman,et al.  Electrode Array-based Electrical Stimulation using ILC with Restricted Input Subspace , 2014 .

[9]  Samar Hamid,et al.  Role of electrical stimulation for rehabilitation and regeneration after spinal cord injury: an overview , 2008, European Spine Journal.

[10]  Silvestro Micera,et al.  Array electrode design for transcutaneous electrical stimulation: a simulation study. , 2009, Medical engineering & physics.

[11]  A. J. del-Ama,et al.  Review of hybrid exoskeletons to restore gait following spinal cord injury. , 2012, Journal of rehabilitation research and development.

[12]  J. Norton,et al.  Patients' perceptions of the Odstock Dropped Foot Stimulator (ODFS) , 1999, Clinical rehabilitation.

[13]  Andrzej Wit,et al.  Mechanisms of compensation in the gait of patients with drop foot , 2017, Clinical biomechanics.

[14]  Warren E. Dixon,et al.  Comparing the Induced Muscle Fatigue Between Asynchronous and Synchronous Electrical Stimulation in Able-Bodied and Spinal Cord Injured Populations , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  Cathy Bulley,et al.  “Functional electrical stimulation (FES) impacted on important aspects of my life”—A qualitative exploration of chronic stroke patients' and carers' perceptions of FES in the management of dropped foot , 2012, Physiotherapy theory and practice.

[16]  Raviraj Nataraj,et al.  Restoring standing capabilities with feedback control of functional neuromuscular stimulation following spinal cord injury. , 2017, Medical engineering & physics.

[17]  M Manjunatha,et al.  Functional electrical stimulation on improving foot drop gait in poststroke rehabilitation: a review of its technology and clinical efficacy. , 2013, Critical reviews in biomedical engineering.

[18]  J. Pons,et al.  A neuroprosthesis for tremor management through the control of muscle co-contraction , 2013, Journal of NeuroEngineering and Rehabilitation.

[19]  F. Tok,et al.  Gait Disturbances in Patients With Stroke , 2014, PM & R : the journal of injury, function, and rehabilitation.

[20]  C. Sadowsky,et al.  Functional electrical stimulation as a component of activity-based restorative therapy may preserve function in persons with multiple sclerosis , 2015, The journal of spinal cord medicine.

[21]  D. Popović,et al.  Distributed low‐frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation , 2010, Muscle & nerve.

[22]  Thierry Keller,et al.  Evolution of Surface Motor Activation Zones in Hemiplegic Patients During 20 Sessions of FES Therapy with Multi-pad Electrodes , 2016, European journal of translational myology.

[23]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.

[24]  Steven A Kautz,et al.  The Effects of Peroneal Nerve Functional Electrical Stimulation Versus Ankle-Foot Orthosis in Patients With Chronic Stroke , 2014, Neurorehabilitation and neural repair.

[25]  M. Kafri,et al.  Therapeutic Effects of Functional Electrical Stimulation on Gait in Individuals Post-Stroke , 2014, Annals of Biomedical Engineering.

[26]  P. Taylor,et al.  Upper limb functional electrical stimulation devices and their man–machine interfaces , 2015, Journal of medical engineering & technology.

[27]  Eduardo Rocon,et al.  Advances in selective activation of muscles for non-invasive motor neuroprostheses , 2016, Journal of NeuroEngineering and Rehabilitation.

[28]  H. van der Kooij,et al.  Selectivity and Resolution of Surface Electrical Stimulation for Grasp and Release , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[29]  Dimitry G. Sayenko,et al.  Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources , 2014, European Journal of Applied Physiology.

[30]  T. Keller,et al.  Electrodes for transcutaneous (surface) electrical stimulation , 2008 .

[31]  Thierry Keller,et al.  A decision support system for electrode shaping in multi-pad FES foot drop correction , 2017, Journal of NeuroEngineering and Rehabilitation.

[32]  Louise Demers,et al.  The Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0): An overview and recent progress , 2002 .

[33]  M. Popovic,et al.  Multi-field surface electrode for selective electrical stimulation. , 2005, Artificial organs.

[34]  Ben W Heller,et al.  Automated setup of functional electrical stimulation for drop foot using a novel 64 channel prototype stimulator and electrode array: results from a gait-lab based study. , 2013, Medical engineering & physics.

[35]  Kari Dunning,et al.  Peroneal Stimulation for Foot Drop After Stroke: A Systematic Review , 2015, American journal of physical medicine & rehabilitation.

[36]  G M Lyons,et al.  An electrode configuration technique using an electrode matrix arrangement for FES-based upper arm rehabilitation systems. , 2006, Medical engineering & physics.