Factors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples

Spectral-domain OCT is an established tool to assist clinicians in detecting glaucoma and monitor disease progression. The widespread use of this imaging modality is due, at least in part, to continuous hardware and software advancements. However, recent evidence indicates that OCT scan artifacts are frequently encountered in clinical practice. Poor image quality invariably challenges the interpretation of test results, with potential implications for the care of glaucoma patients. Therefore, adequate knowledge of various imaging artifacts is necessary. In this work, we describe several factors affecting Cirrus HD-OCT optic disc scan quality and their effects on measurement variability.

[1]  L. Labree,et al.  Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography. , 2007, Ophthalmology.

[2]  V. P. Costa,et al.  Influence of pupil dilation on retinal nerve fibre layer measurements with spectral domain OCT , 2009, Eye.

[3]  C. Curcio,et al.  Peripapillary chorioretinal atrophy: Bruch's membrane changes and photoreceptor loss. , 2000, Ophthalmology.

[4]  G. Savini,et al.  Influence of Pupil Size and Cataract on Retinal Nerve Fiber Layer Thickness Measurements by Stratus OCT , 2006, Journal of glaucoma.

[5]  H. Littmann [Determination of the real size of an object on the fundus of the living eye]. , 1982, Klinische Monatsblatter fur Augenheilkunde.

[6]  G. Savini,et al.  The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT , 2011, British Journal of Ophthalmology.

[7]  R. Harwerth,et al.  Influence of anterior segment power on the scan path and RNFL thickness using SD-OCT. , 2012, Investigative ophthalmology & visual science.

[8]  L. Pierro,et al.  Spectral-domain optical coherence tomography evaluation of vitreoretinal adhesions in idiopathic epiretinal membranes , 2014, Graefe's Archive for Clinical and Experimental Ophthalmology.

[9]  P A Keane,et al.  Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography , 2009, British Journal of Ophthalmology.

[10]  Hiroshi Ishikawa,et al.  Effect of corneal drying on optical coherence tomography. , 2006, Ophthalmology.

[11]  Glenn J Jaffe,et al.  Evaluation of artifacts associated with macular spectral-domain optical coherence tomography. , 2010, Ophthalmology.

[12]  H. Flynn,et al.  "Floater scotoma" demonstrated on spectral-domain optical coherence tomography and caused by vitreous opacification. , 2013, Ophthalmic surgery, lasers & imaging retina.

[13]  Robert N Weinreb,et al.  Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography. , 2009, Optics express.

[14]  Robert N Weinreb,et al.  Effect of Improper Scan Alignment on Retinal Nerve Fiber Layer Thickness Measurements Using Stratus Optical Coherence Tomograph , 2008, Journal of glaucoma.

[15]  Y. Hwang,et al.  Retinal Nerve Fiber Layer Thickness Measurement Repeatability for Cirrus HD-OCT Retinal Tracking System During Eye Movement , 2016, Journal of glaucoma.

[16]  E. Akpek,et al.  Overview of age-related ocular conditions. , 2013, The American journal of managed care.

[17]  K. Qiu,et al.  The effect of myopia on retinal nerve fibre layer measurement: a comparative study of spectral-domain optical coherence tomography and scanning laser polarimetry , 2010, British Journal of Ophthalmology.

[18]  Gianmarco Vizzeri,et al.  Effect of motion artifacts and scan circle displacements on Cirrus HD-OCT retinal nerve fiber layer thickness measurements. , 2014, Investigative ophthalmology & visual science.

[19]  Cathy Frey,et al.  Investigative Ophthalmology and Visual Science , 2010 .

[20]  Joel S Schuman,et al.  Spectral domain optical coherence tomography for glaucoma (an AOS thesis). , 2008, Transactions of the American Ophthalmological Society.

[21]  G. Savini,et al.  Effect of pupil dilation on retinal nerve fibre layer thickness measurements and their repeatability with Cirrus HD-OCT , 2010, Eye.

[22]  Tin Aung,et al.  Determinants of quantitative optic nerve measurements using spectral domain optical coherence tomography in a population-based sample of non-glaucomatous subjects. , 2011, Investigative ophthalmology & visual science.

[23]  Thomas J T P van den Berg,et al.  The relationship between the optical density of cataract and its influence on retinal nerve fibre layer thickness measured with spectral domain optical coherence tomography , 2013, Acta ophthalmologica.

[24]  Y. Hwang,et al.  Errors in neuroretinal rim measurement by Cirrus high-definition optical coherence tomography in myopic eyes , 2012, British Journal of Ophthalmology.

[25]  C. Cheung,et al.  Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. , 2008, Ophthalmology.

[26]  Joel S Schuman,et al.  Clinical assessment of mirror artifacts in spectral-domain optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[27]  J. Jeoung,et al.  Vitreopapillary traction in eyes with idiopathic epiretinal membrane: a spectral-domain optical coherence tomography study. , 2014, Ophthalmology.

[28]  F. Medeiros,et al.  Effect of signal strength and improper alignment on the variability of stratus optical coherence tomography retinal nerve fiber layer thickness measurements. , 2009, American journal of ophthalmology.

[29]  Piero Barboni,et al.  Spectral-domain optical coherence tomography for the diagnosis and follow-up of glaucoma , 2011, Current opinion in ophthalmology.

[30]  Y. Hwang,et al.  The effect of head tilt on the measurements of retinal nerve fibre layer and macular thickness by spectral-domain optical coherence tomography , 2011, British Journal of Ophthalmology.

[31]  Ziqiang Wu,et al.  Signal Strength is an Important Determinant of Accuracy of Nerve Fiber Layer Thickness Measurement by Optical Coherence Tomography , 2009, Journal of glaucoma.

[32]  Robert N Weinreb,et al.  Role of optic nerve imaging in glaucoma clinical practice and clinical trials. , 2008, American journal of ophthalmology.

[33]  A. Galor,et al.  Glaucoma therapy and ocular surface disease: current literature and recommendations , 2013, Current opinion in ophthalmology.

[34]  Sanjay Asrani,et al.  Artifacts in spectral-domain optical coherence tomography measurements in glaucoma. , 2014, JAMA ophthalmology.

[35]  Seung Woo Hong,et al.  Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[36]  L. Zangwill,et al.  Role of imaging in glaucoma diagnosis and follow-up , 2011, Indian journal of ophthalmology.

[37]  David P. Crabb,et al.  Aligning Scan Acquisition Circles in Optical Coherence Tomography Images of The Retinal Nerve Fibre Layer , 2011, IEEE Transactions on Medical Imaging.

[38]  C. Leung Diagnosing glaucoma progression with optical coherence tomography. , 2014, Current opinion in ophthalmology.

[39]  Y. Hwang,et al.  Effect of peripapillary vitreous opacity on retinal nerve fiber layer thickness measurement using optical coherence tomography. , 2012, Archives of ophthalmology.

[40]  B. Nan,et al.  Trends in use of ancillary glaucoma tests for patients with open-angle glaucoma from 2001 to 2009. , 2012, Ophthalmology.

[41]  W. Feuer,et al.  Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. , 2012, Archives of ophthalmology.

[42]  C. Cheung,et al.  Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling study , 2009, Eye.

[43]  Eun Suk Lee,et al.  Influence of Cataract on Time Domain and Spectral Domain Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements , 2010, Journal of glaucoma.

[44]  Hiroshi Ishikawa,et al.  Optical coherence tomography: history, current status, and laboratory work. , 2011, Investigative ophthalmology & visual science.

[45]  J. Duker,et al.  Analysis of peripapillary atrophy using spectral domain optical coherence tomography. , 2010, Ophthalmology.

[46]  Nicholas G Strouthidis,et al.  Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets. , 2009, Investigative ophthalmology & visual science.

[47]  N. Congdon,et al.  Prevalence of cataract and pseudophakia/aphakia among adults in the United States. , 2004, Archives of ophthalmology.

[48]  N. Strouthidis,et al.  Comparison of clinical and three-dimensional histomorphometric optic disc margin anatomy. , 2009, Investigative ophthalmology & visual science.

[49]  C. Cheung,et al.  Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. , 2006, Investigative ophthalmology & visual science.

[50]  Sonia H. Yoo,et al.  Effect of Cataract and its Removal on Signal Strength and Peripapillary Retinal Nerve Fiber Layer Optical Coherence Tomography Measurements , 2011, Journal of glaucoma.

[51]  Hiroshi Ishikawa,et al.  Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability. , 2008, Investigative ophthalmology & visual science.

[52]  L. Pablo,et al.  Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography , 2013, British Journal of Ophthalmology.

[53]  F. Medeiros,et al.  The pathophysiology and treatment of glaucoma: a review. , 2014, JAMA.