Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging.

Current volumetric computed tomography (CT) methods require seconds to acquire a thick volume (>8 cm) with high resolution. Inverse-geometry CT (IGCT) is a new system geometry under investigation that is anticipated to be able to image a thick volume in a single gantry rotation with isotropic resolution and no cone-beam artifacts. IGCT employs a large array of source spots opposite a smaller detector array. The in-plane field of view (FOV) is primarily determined by the size of the source array, in much the same way that the FOV is determined by the size of the detector array in a conventional CT system. Thus, the size of the source array can be a limitation on the achievable FOV. We propose adding additional detector arrays, spaced apart laterally, to increase the in-plane FOV while still using a modestly sized source array. We determine optimal detector placement to maximize the FOV while obtaining relatively uniform sampling. We also demonstrate low wasted radiation of the proposed system through design and simulation of a pre-patient collimator. Reconstructions from simulated projection data show no artifacts when combining the data from the detector arrays. Finally, to demonstrate feasibility of the concept, an anthropomorphic thorax phantom containing a porcine heart was scanned on a prototype table-top system. The reconstructed axial images demonstrate a 45 cm in-plane FOV using a 23 cm source array.

[1]  N. Pelc,et al.  An inverse-geometry volumetric CT system with a large-area scanned source: a feasibility study. , 2004, Medical physics.

[2]  K F King,et al.  Computed tomography scanning with simultaneous patient translation. , 1990, Medical physics.

[3]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[4]  W. Kalender,et al.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.

[5]  H Hu,et al.  Multi-slice helical CT: scan and reconstruction. , 1999, Medical physics.

[6]  Bruce D. Smith Cone-beam tomography: recent advances and a tutorial review , 1990 .

[7]  K R Hoffman,et al.  In the next decade automated computer analysis will be an accepted sole method to separate "normal" from "abnormal" radiological images. , 1999, Medical physics.

[8]  Josh Star-Lack,et al.  2D simulations of an inverse-geometry volumetric CT system with multiple detector arrays , 2005, SPIE Medical Imaging.

[9]  Taly Gilat Schmidt,et al.  A prototype table‐top inverse‐geometry volumetric CT system , 2006 .

[10]  R A Kruger,et al.  Dual-slice spiral versus single-slice spiral scanning: comparison of the physical performance of two computed tomography scanners. , 1996, Medical physics.

[11]  Edward G. Solomon,et al.  Scanning-beam digital x-ray (SBDX) system for cardiac angiography , 1999, Medical Imaging.

[12]  Norbert J. Pelc,et al.  Motion artifacts from an inverse-geometry CT system with multiple detector arrays , 2006, SPIE Medical Imaging.

[13]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[14]  Taly Gilat Schmidt,et al.  Geometry analysis of an inverse-geometry volumetric CT system with multiple detector arrays , 2004, SPIE Medical Imaging.

[15]  J. D. O'Sullivan,et al.  A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer Tomography , 1985, IEEE Transactions on Medical Imaging.