Measuring cell adhesion on RGD-modified, self-assembled PEG monolayers using the quartz crystal microbalance technique.

In this study, the suitability of a flow-through quartz crystal microbalance system for the detection of the adhesion of rMSCs and 3T3-L1 fibroblasts on different surfaces is demonstrated. Frequency shifts for rMSCs of -6.7 mHz x cell(-1) and -2.0 mHz x cell(-1) for 3T3-L1 cells could be detected on non-modified gold sensors, revealing that the frequency shift per cell is comparable to that of a static setup. Modifying the sensor surface with SAMs of thioalkylated omega-amine-terminated PEG derivatives led to cell-adhesion-resistant surfaces. Total frequency shifts of only -20 +/- 7 Hz showed that protein adsorption was also significantly reduced. Attaching 35 pmol x mm(-2) of the GRGDS cell adhesion motif to the SAMs induced specific cell adhesion due to RGD-integrin interactions; the resonance frequency dropped by 3.4 mHz x cell(-1). Furthermore, the kinetics of cell detachment could be determined. The corresponding processes were completed after 10 min for trypsin, and not before 90 min with GRGDS. Moreover, the detectability of cell adhesion was shown to increase after the addition of manganese cations. The total decrease in the resonance frequency was almost 80 Hz in the presence of Mn(2+) (6.4 mHz x cell(-1)). [image: see text] Staining the cytoskeleton of the rMSCs shows that the GRGDS-modified surfaces are almost completely covered with well-spread cells.

[1]  Horst Kessler,et al.  RGD modified polymers: biomaterials for stimulated cell adhesion and beyond. , 2003, Biomaterials.

[2]  P. Kingshott,et al.  Surfaces that resist bioadhesion , 1999 .

[3]  K. Marx,et al.  Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix. , 2005, Analytical biochemistry.

[4]  K. Marx,et al.  Quartz Crystal Microbalance Study of Endothelial Cell Number Dependent Differences in Initial Adhesion and Steady‐State Behavior: Evidence for Cell‐Cell Cooperativity in Initial Adhesion and Spreading , 2003, Biotechnology progress.

[5]  A. Mikos,et al.  The use of poly(ethylene glycol)-block-poly(lactic acid) derived copolymers for the rapid creation of biomimetic surfaces. , 2003, Biomaterials.

[6]  J. Bertram,et al.  Quartz crystal microbalance‐based measurements of shear‐induced senescence in human embryonic kidney cells , 2004, Biotechnology and bioengineering.

[7]  D E Ingber,et al.  Using microcontact printing to pattern the attachment of mammalian cells to self-assembled monolayers of alkanethiolates on transparent films of gold and silver. , 1997, Experimental cell research.

[8]  K. Marx,et al.  A quartz crystal microbalance cell biosensor: detection of microtubule alterations in living cells at nM nocodazole concentrations. , 2001, Biosensors & bioelectronics.

[9]  A. Göpferich,et al.  Biomimetic polymers in pharmaceutical and biomedical sciences. , 2004, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[10]  K. Marx,et al.  Quartz crystal microbalance: a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface. , 2003, Biomacromolecules.

[11]  Aseel Hassan,et al.  Total internal reflection ellipsometry and SPR detection of low molecular weight environmental toxins , 2005 .

[12]  R. Corn,et al.  Surface plasmon resonance imaging measurements of DNA and RNA hybridization adsorption onto DNA microarrays. , 2001, Analytical chemistry.

[13]  J. M. Ross,et al.  Shear Stress Prevents Fibronectin Binding Protein-Mediated Staphylococcus aureus Adhesion to Resting Endothelial Cells , 2001, Infection and Immunity.

[14]  Jing Li,et al.  Monitoring of integrin-mediated adhesion of human ovarian cancer cells to model protein surfaces by quartz crystal resonators: evaluation in the impedance analysis mode. , 2005, Biosensors & bioelectronics.

[15]  M. Neubauer,et al.  Basic fibroblast growth factor enhances PPARγ ligand‐induced adipogenesis of mesenchymal stem cells , 2004, FEBS letters.

[16]  C. Steinem,et al.  Piezoelectric Mass-Sensing Devices as Biosensors-An Alternative to Optical Biosensors? , 2000, Angewandte Chemie.

[17]  T. Okano,et al.  Synthesis of poly(ethylene oxide) with heterobifunctional reactive groups at its terminals by an anionic initiator. , 1992, Bioconjugate chemistry.

[18]  B. Kasemo,et al.  Simultaneous frequency and dissipation factor QCM measurements of biomolecular adsorption and cell adhesion. , 1997, Faraday discussions.

[19]  Andreas Janshoff,et al.  Cell adhesion monitoring using a quartz crystal microbalance: comparative analysis of different mammalian cell lines , 1998, European Biophysics Journal.

[20]  P. Laugier,et al.  Monitoring cell adhesion processes on bioactive polymers with the quartz crystal resonator technique. , 2005, Biomaterials.

[21]  M. D. Ward,et al.  Real‐Time Measurement of Anchorage‐Dependent Cell Adhesion Using a Quartz Crystal Microbalance , 1993, Biotechnology progress.

[22]  C. Steinem,et al.  Adhesion kinetics of functionalized vesicles and mammalian cells: A comparative study , 2003 .

[23]  G. Whitesides,et al.  Formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold , 1989 .

[24]  B. Kasemo,et al.  The Piezoelectric Quartz Crystal Mass and Dissipation Sensor: A Means of Studying Cell Adhesion , 1998 .

[25]  L. Schlapbach,et al.  Cell spreading on quartz crystal microbalance elicits positive frequency shifts indicative of viscosity changes , 2003, Analytical and bioanalytical chemistry.

[26]  A. Göpferich,et al.  Biodegradable poly(D,L-lactic acid)-poly(ethylene glycol)-monomethyl ether diblock copolymers: structures and surface properties relevant to their use as biomaterials. , 2000, Biomaterials.

[27]  A. Göpferich,et al.  Impedance and QCM analysis of the protein resistance of self-assembled PEGylated alkanethiol layers on gold. , 2005, Biomaterials.

[28]  F. Grinnell Manganese-dependent cell-substratum adhesion. , 1984, Journal of cell science.

[29]  Hongwei Ma,et al.  Surface engineering strategies for control of protein and cell interactions , 2004 .

[30]  Joseph D. Andrade,et al.  Blood compatibility of polyethylene oxide surfaces , 1995 .

[31]  C. Satriano,et al.  Pericyte adhesion and growth onto polyhydroxymethylsiloxane surfaces nanostructured by plasma treatment and ion irradiation. , 2004, Microvascular research.

[32]  V. Gerke,et al.  Kinetics and thermodynamics of annexin A1 binding to solid-supported membranes: a QCM study. , 2002, Biochemistry.

[33]  Hidetoshi Sato,et al.  A rapid biosensor chip assay for measuring of telomerase activity using surface plasmon resonance. , 2003, Nucleic acids research.

[34]  B. Kasemo,et al.  In vitro real-time characterization of cell attachment and spreading , 1998, Journal of materials science. Materials in medicine.

[35]  K. Marx,et al.  The Quartz Crystal Microbalance as a Continuous Monitoring Tool for the Study of Endothelial Cell Surface Attachment and Growth , 2000, Biotechnology progress.

[36]  M J Yaszemski,et al.  Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds. , 1997, Journal of biomedical materials research.

[37]  N. Hogg,et al.  The regulation of integrin function by Ca(2+). , 2000, Biochimica et biophysica acta.

[38]  C. Cabañas,et al.  Regulation of integrin function. , 1996, Seminars in cancer biology.

[39]  H. Galla,et al.  Analysis of the composite response of shear wave resonators to the attachment of mammalian cells. , 2000, Biophysical journal.