Computerized ventilator data selection: artifact rejection and data reduction

Objective: To determine acceptable strategies for automated data acquisition and artifact rejection from computerized ventilators using the Medical Information Bus. Design: Medical practitioners were surveyed to establish ‘clinically important’ ventilator events. A prospective study involving frequent data collection from ventilators was also conducted. Subjects: Data from 10 adult patients were collected every 10 seconds from a Puritan Bennett 7200A ventilator for a total of 617.1 hours. Interventions: Twelve different computerized data selection and artifact algorithms were tested and evaluated. Measurements and Main Results: Data derived from 12 data selection algorithms were compared with each other and with data manually charted by respiratory therapists into a computerized charting system. Ventilator setting data collected by the algorithms, such as FIO2, reduced the amount of data collected to about 25% compared to manually charted data. The amount of data collected for measured parameters, such as tidal volume, from the ventilator had large variability and many artifacts. Automated data capture and selection generally increased the amount of data collected compared to manual charting, for example for the 3 minute median the increase was a modest 1.2 times. Conclusion: Computerized methods for collecting ventilator setting data were relatively straightforward and more efficient than manual methods. However, the method for automated selection and presentation of observed measured parameters is much more difficult. Based on the findings and analysis presented here, the authors recommend recording ventilator setting data after they have existed for three minutes and measured parameters using a three minute median data selection strategy. Such an algorithm rejected most artifacts, required minimal computational time, had minimal time-delay, and provided clinically acceptable data acquisition. The results presented here are but a starting point in developing automated ventilator data selection strategies.

[1]  G. Passariello,et al.  Intelligent patient monitoring and management systems: a review , 1993, IEEE Engineering in Medicine and Biology Magazine.

[2]  R M Gardner,et al.  Computerized management of intensive care patients. , 1987 .

[3]  D. Harrington Medical device networks. , 1990, Journal of clinical engineering.

[4]  C. Elliott Computer-assisted quality assurance: development and performance of a respiratory care program. , 1991, QRB. Quality review bulletin.

[5]  R M Gardner,et al.  Real time data acquisition: recommendations for the medical information bus (MIB) , 1991, International journal of clinical monitoring and computing.

[6]  R M Gardner,et al.  Computerized detection of arterial oxygen desaturations in an intensive care unit. , 1993, Proceedings. Symposium on Computer Applications in Medical Care.

[7]  R M Gardner,et al.  Medical informatics in the intensive care unit: state of the art 1991 , 1991, International journal of clinical monitoring and computing.

[8]  R. Gardner,et al.  The Future of Computerized Decision Support in Critical Care , 1994 .

[9]  R M Gardner,et al.  Physician decision-making--evaluation of data used in a computerized ICU. , 1984, International journal of clinical monitoring and computing.

[10]  Arnon D. Cohen,et al.  Biomedical Signal Processing , 1986 .

[11]  H. Warner,et al.  Computer‐based ICU data acquisition as an aid to clinical decision‐making , 1982, Critical care medicine.

[12]  R M Gardner,et al.  Computers in critical care. , 1995, Critical care nursing clinics of North America.

[13]  E. B. Steen,et al.  The Computer-Based Patient Record: An Essential Technology for Health Care , 1992, Annals of Internal Medicine.

[14]  W. Cleveland,et al.  Locally Weighted Regression: An Approach to Regression Analysis by Local Fitting , 1988 .

[15]  R M Gardner,et al.  Digital electronic communication between ICU ventilators and computers and printers. , 1992, Respiratory care.

[16]  J. Reggia,et al.  HELP: A Dynamic Hospital Information System , 1991, Computers and Medicine.

[17]  R M Gardner,et al.  Representative charting of vital signs in an intensive care unit. , 1994, Proceedings. Symposium on Computer Applications in Medical Care.

[18]  R M Gardner,et al.  Computer charting: an evaluation of a respiratory care computer system. , 1985, Respiratory care.

[19]  Dean F. Sittig,et al.  Randomized clinical trial of pressure-controlled inverse ratio ventilation and extracorporeal CO2 removal for adult respiratory distress syndrome. , 1994, American journal of respiratory and critical care medicine.

[20]  C J McDonald,et al.  Standard formats for electronic transfer of clinical data. , 1989, Annals of internal medicine.

[21]  R M Gardner,et al.  Editorial; medical information bus: The key to future integrated monitoring , 1989, International journal of clinical monitoring and computing.

[22]  M M Shabot,et al.  Standardized acquisition of bedside data: The IEEE P1073 medical information bus , 1989, International journal of clinical monitoring and computing.

[23]  S. Huff,et al.  Computers in the ICU: Why? What? and So What? , 1992, International journal of clinical monitoring and computing.

[24]  H. Warner,et al.  Decision support in medicine: examples from the HELP system. , 1994, Computers and biomedical research, an international journal.

[25]  J. H. Strickland,et al.  A Computer-controlled Ventilator Weaning System: A Clinical Trial , 1993 .

[26]  C G Ward,et al.  A qualitative comparison of paper flowsheets vs a computer-based clinical information system. , 1991, Chest.