Application of factorial design to improve a FIA system for penicillin determination

A potentiometric FIA system for penicillin determination, employing penicillinase [E.C. 3.5.2.6] immobilized on silica gel, packed into a reactor, was improved by the use of statistically designed experiments. A two-level and three-factor factorial was used to find the best working conditions evaluating the influence of some parameters on the signal response of the system and the number of determinations per hour. These parameters were analyzed individually obtaining two level of the variables to be used in the factorial design: length of the reactor (1.5 and 2.0 cm), carrier flow rate (1.6 and 2.2 ml min−1) and sample volume (100 and 150 μl). The pure error on the measurements was estimated by authentic repetitions. The ideal working conditions taking into account a compromise between the best response signal and the number of determinations per hour (with the same importance) being chosen the level of factors: length of reactor 1.5 cm, carrier flow rate 2.2 ml min−1 and sample volume of 150 μl. Under these conditions the system allowed to analyze was about 45 samples per hour, during 73 days, with a standard deviation of 2.4% at concentration range between 10−1 and 10−3 mol l−1.

[1]  Bengt Danielsson,et al.  Flow injection analysis with enzyme thermistor detector for automated determination of .beta.-lactams , 1984 .

[2]  Howard H. Weetall,et al.  [10] Covalent coupling methods for inorganic support materials , 1976 .

[3]  H. Mottola,et al.  Flow injection determination of penicillins using immobilized penicillinase in a single bead string reactor. , 1985, Analytical chemistry.

[4]  G D Christian,et al.  Single fiber-optic fluorescence enzyme-based sensor. , 1988, Analytical chemistry.

[5]  J. Burguera,et al.  Factorial design for the response exploration of a flow injection system. , 1995, Talanta.

[6]  T. Scheper,et al.  Penicillin G sensor based on penicillin amidase coupled to a field effect transistor , 1989 .

[7]  B. Olsson A flow-injection system based on immobilized penicillinase and a linear pH-buffer for potentiometric determination of penicillin , 1988 .

[8]  Ashok Mulchandani,et al.  The development of an amperometric microbial biosensor using Acetobacter pasteurianus for lactic acid , 1989 .

[9]  R. Henrion,et al.  Multivariate correction of chemical interferences in hydride generation atomic absorption spectrometry , 1992 .

[10]  M. Arruda,et al.  Experimental fluctuations of flow-injection signals , 1992 .

[11]  D. Higgs,et al.  Laminar dispersion in flow-injection analysis. , 1981, Talanta.

[12]  G. Kateman,et al.  Experimental optimization procedures in the determination of phosphate by flow-injection analysis , 1983 .

[13]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[14]  C. Tran-Minh,et al.  Determination of penicillin-V in standard solution and in fermentation broth by flow-injection analysis using fast-responding enzyme glass electrodes in different detection cells , 1992 .

[15]  R. Michel,et al.  Optimization of a direct-current plasma emission echelle spectrometer , 1987 .

[16]  A. Bult,et al.  Determination of penicillin in pharmaceutical formulations by flow injection analysis using an optimised immobilised penicillinase reactor and iodometric detection. , 1990, Journal of pharmaceutical and biomedical analysis.