Effect of image compression and resolution on retinal vascular caliber.

PURPOSE Changes in retinal vascular caliber measured from digital color fundus photographs have been independently associated with systemic outcomes in epidemiologic studies, but the effect of image resolution and compression on vascular measurements has not been previously evaluated. METHODS To explore image compression, 40 natively digital fundus images were selected with good photo quality, high spatial resolution, and no previous image compression. Using Adobe Photoshop, these images were compressed at progressively higher levels up to 147:1, and then retinal vascular caliber was measured at each level using semiautomated software. To examine resolution, 40 fundus photographs acquired on high-resolution film were scanned with settings corresponding to 10, 7, 5, 3, and 1 megapixel fundus cameras. After adjusting for scale factor, vascular caliber was measured at each level of resolution. Data were analyzed by comparing the calculated central retinal arteriole equivalent (CRAE) and the central retinal venular equivalent (CRVE) of the original and altered images, using repeated measures ANOVA. RESULTS CRAE became significantly wider with increasing levels of compression at the 25:1 threshold (~1 μm wider, P < 0.001) and was ~5 μm wider with 147:1 compression. CRVE also increased, but less than CRAE. Using 7 (megapixel)-MP resolution as the standard, CRVE was significantly narrower at the 5-MP simulation (~2 μm, P < 0.001) and was ~12 μm narrower at the 1-MP simulation. CRAE also decreased, but less than CRVE. CONCLUSIONS Increasing digital image file compression and decreasing fundus image spatial resolution led to skewed measurements of the retinal vascular caliber.

[1]  R. Klein,et al.  Revised formulas for summarizing retinal vessel diameters , 2003, Current eye research.

[2]  R. Klein,et al.  Retinal vascular caliber, cardiovascular risk factors, and inflammation: the multi-ethnic study of atherosclerosis (MESA). , 2006, Investigative ophthalmology & visual science.

[3]  E. Kohner,et al.  Vessel diameter changes during the cardiac cycle , 1994, Eye.

[4]  Timothy J. Vitale Projecting Digital 'Slide' Images , 2003 .

[5]  C J Barry,et al.  Methods and limits of digital image compression of retinal images for telemedicine. , 2000, Investigative ophthalmology & visual science.

[6]  Wei Su,et al.  A generalized Benford's law for JPEG coefficients and its applications in image forensics , 2007, Electronic Imaging.

[7]  Tien Yin Wong,et al.  Retinal arteriolar narrowing, hypertension, and subsequent risk of diabetes mellitus. , 2005, Archives of internal medicine.

[8]  R. Klein,et al.  Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle , 2003, The British journal of ophthalmology.

[9]  Hany Farid,et al.  Statistical Tools for Digital Forensics , 2004, Information Hiding.

[10]  R. Klein,et al.  Retinal venular diameter as an early indicator of progression to proliferative diabetic retinopathy with and without high-risk characteristics in African Americans with type 1 diabetes mellitus. , 2011, Archives of ophthalmology.

[11]  A Erginay,et al.  Evaluation of the effect of JPEG and JPEG2000 image compression on the detection of diabetic retinopathy , 2007, Eye.

[12]  T. Wong,et al.  Retinal vascular caliber: systemic, environmental, and genetic associations. , 2009, Survey of ophthalmology.