Valve-Actuator-Integrated Reference Electrode for an Ultra-Long-Life Rumen pH Sensor

We demonstrated a newly developed Ag/AgCl reference electrode- with a valve-actuator for two years or longer rumen pH monitoring. Previous studies on pH sensors reported that the short lifetime of Ag/AgCl reference electrodes is caused by an outflow of internal electrolyte. We introduced a valve-actuator into a liquid junction to reduce the outflow by intermittent measurement. The results indicated that the potential change when switching the liquid junction was less than 0.5 mV and its response time was less than 0.083 s. In the 24-h potential measurement with the valve-actuator-integrated reference electrode (VAIRE), the valve was actuated once every hour, and the standard deviation of the potential was 0.29 mV. The lifetime of the VAIRE was estimated at 2.0 years calculating from an electrolyte outflow, which is significantly longer than that of conventional reference electrodes. A pH sensor using the VAIRE was estimated to operate for 2.0 years with the pH error ≤0.1, which meets the requirement of cows’ rumen pH monitoring.

[1]  S. Ito,et al.  Improvement of the silver/silver chloride reference electrode and its application to pH measurement. , 1995, Talanta.

[2]  U. Guth,et al.  An all-solid-state reference electrode , 2010 .

[3]  A. Stein,et al.  Rational design of all-solid-state ion-selective electrodes and reference electrodes , 2016 .

[4]  M. Deen,et al.  Electrochemical growth of high-aspect ratio nanostructured silver chloride on silver and its application to miniaturized reference electrodes , 2011, Nanotechnology.

[5]  Masayuki Itagaki,et al.  Improvement in the long-term stability of screen-printed planar type solid-state Ag/AgCl reference electrode by introducing poly(dimethylsiloxane) liquid junction , 2011 .

[6]  B. Krevet,et al.  Normally-closed shape memory microvalve , 2001 .

[7]  Jian Lu,et al.  Low-Power Highly Sensitive pH Sensor With $\mu$ dots Protective Structures for Monitoring Rumen in Cows in Real-Time , 2017, IEEE Sensors Journal.

[8]  T. Itoh,et al.  Solid-state pH sensor prototype for real-time monitoring of the rumen pH value of Japanese cows , 2018 .

[9]  An instantly usable paper-based screen-printed solid-state KCl/Ag/AgCl reference electrode with long-term stability. , 2015, The Analyst.

[10]  Hitoshi Mizuguchi,et al.  Technical note: development and testing of a radio transmission pH measurement system for continuous monitoring of ruminal pH in cows. , 2012, Preventive veterinary medicine.

[11]  U. Guth,et al.  Solid-state reference electrodes for potentiometric sensors , 2009 .

[12]  Chong H. Ahn,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering a Review of Microvalves , 2022 .

[13]  P. Bühlmann,et al.  Avoiding Errors in Electrochemical Measurements: Effect of Frit Material on the Performance of Reference Electrodes with Porous Frit Junctions. , 2016, Analytical chemistry.

[14]  Tae Yong Kim,et al.  A Solid-State Thin-Film Ag/AgCl Reference Electrode Coated with Graphene Oxide and Its Use in a pH Sensor , 2015, Sensors.

[15]  T. Itoh,et al.  Ultra-Long-Life Miniature pH Sensor with a SMA Valve-Actuator Integrated Liquid Junction for Rumen Monitoring , 2019, 2019 20th International Conference on Solid-State Sensors, Actuators and Microsystems & Eurosensors XXXIII (TRANSDUCERS & EUROSENSORS XXXIII).

[16]  Jian Lu,et al.  Developing a Solid-State pH Sensor for Wagyu-Rumen Monitoring , 2016 .

[17]  Isao Karube,et al.  Micromachined liquid-junction Ag/AgCl reference electrode , 1998 .

[18]  Isao Karube,et al.  Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor , 1999 .

[19]  P. Ravi Selvaganapathy,et al.  Microfluidic Reference Electrode with Free-Diffusion Liquid Junction , 2013 .

[20]  Toby Mottram,et al.  Technical note: A wireless telemetric method of monitoring clinical acidosis in dairy cows , 2008 .

[21]  Werner E. Morf,et al.  Reference electrode with free-flowing free-diffusion liquid junction , 1986 .

[22]  Paul J. Brewer,et al.  An improved approach for fabricating Ag/AgCl reference electrodes , 2012 .