This paper presents an analysis of the impact of selected design alternatives on the thermal and energy performance of atriums based on the methodology outlined in the accompanying paper. Computer simulation programs were used to predict the impact of the selected design alternatives on the design performance outputs of atriums. Design alternatives focused on fenestration glazing types, fenestration surface area, skylight shape, atrium type, and interaction of the atrium with its adjacent spaces. Design performance outputs, evaluated with respect to a basecase design, included seasonal solar heat gain ratio, cooling and heating peak load ratios and annual cooling, heating and total energy ratios. Design tools were developed to quantify the impact of the design alternatives on the performance outputs. The design tools were cast into two-dimensional linear relationships with the glazing U-value and SHGC ratios as independent parameters. The results for enclosed atriums showed that the annual cooling energy ratio increased at a rate of 1.196 per unit of SHGC ratio and decreased at a rate of 0.382 per unit of U-value ratio. However, the annual heating energy ratio increased at a rate of 1.954 per unit of U-value ratio and decreased at a rate of 1.081 per unit of SHGC ratio. Similar trends were also found for the three-sided and linear atriums. Pyramidal/pitched skylights increased the solar heat gain ratio by up to 25% in the heating season compared to flat skylights. The effect of the skylight shape on the annual cooling and heating energy may be positive or negative, depending on the glazing U-value and SHGC ratios and the atrium type. Atriums open to their adjacent spaces reduced the annual cooling energy ratio by up to 76% compared to closed atrium spaces. However, open atrium spaces increased the annual heating energy ratio by up to 19%.
[1]
X. Yuan,et al.
Numerical modeling of heat transfer by radiation and convection in an atrium with thermal inertia
,
1995
.
[2]
J. W. Hanford,et al.
Relationship between electrical loads and ambient temperature in two monitored commercial buildings
,
1986
.
[3]
Hiroshi Yoshino,et al.
Trends in thermal environmental design of atrium buildings in Japan
,
1996
.
[4]
Yuichi Takemasa,et al.
Application of an unsteady-state model for predicting vertical temperature distribution to an existing atrium
,
1996
.
[5]
A. Moser,et al.
Energy-efficient ventilation of large enclosures
,
1998
.
[6]
E. O. Kainlauri,et al.
ATRIUM DESIGN CRITERIA RESULTING FROM COMPARATIVE STUDIES OF ATRIUMS WITH DIFFERENT ORIENTATION AND COMPLEX INTERFACING OF ENVIRONMENT AL SYSTEMS
,
1993
.
[7]
Maria Wall.
Climate and Energy Use in Glazed Spaces
,
1996
.
[8]
Satoshi Togari,et al.
Unsteady-state thermal analysis of a large space with vertical temperature distribution
,
1994
.
[9]
G.G.J. Achterbosch,et al.
The development of a comvenient thermal dynamic building model
,
1985
.
[10]
Shuzo Murakami,et al.
CFD analysis of flow and temperature fields in atrium with ceiling height of 130 m
,
1995
.
[11]
Wan Ki Chow.
Assessment of Thermal Environment in an Atrium with Air-Conditioning
,
1996
.