Optimal design of a compliant mechanism with circular notch flexure hinges

Abstract This paper presents an optimal design of a compliant mechanism with circular notch flexure hinges as well as a performance evaluation of a two-axes ultra-precision stage using the compliant mechanism. The compliant mechanism consists of two double-symmetric four-link mechanisms for two translational motions. As the circular notch flexure hinge can produce rotation as well as axial translation via its deformation, the double symmetric four-link mechanism can translate along one direction in a small range. In the optimal design, a composite global design index based on Min-Max principle is applied for the design of the compliant mechanism with circular notch flexure hinges owing to its simplicity and compactness. The designed compliant mechanism, piezoelectric elements for actuation, and capacitance-type displacement sensors for position measurement are assembled into an ultra-precision stage. The experimental results show that the stage implemented by the compliant mechanism will be applicable to two-axes ultra-precision positioning systems such as the fine positioning table of coarse-fine positioning systems, ultra-precision machining centres, wafer stages, and scanners for atomic force microscopy (AFM).

[1]  Il Hong Suh,et al.  Optimal design and development of a five-bar finger with redundant actuation , 2001 .

[2]  Jae Hoon Lee,et al.  Optimization and experimental verification for the antagonistic stiffness in redundantly actuated mechanisms: a five-bar example , 2005 .

[3]  George J. Klir,et al.  Fuzzy sets, uncertainty and information , 1988 .

[4]  M. Lagally,et al.  Flexural-hinge guided motion nanopositioner stage for precision machining : Finite element simulations , 2001 .

[5]  Stuart T. Smith,et al.  Flexures: Elements of Elastic Mechanisms , 2000 .

[6]  K-B Choi Dynamics of a compliant mechanism based on flexure hinges , 2005 .

[7]  Musa Jouaneh,et al.  Design and characterization of a low-profile micropositioning stage , 1996 .

[8]  D. Gweon,et al.  Optimal design of a flexure hinge-based XYZ atomic force microscopy scanner for minimizing Abbe errors , 2005 .

[9]  Byung-Ju Yi,et al.  Optimal kinematic design of an anthropomorphic robot module with redundant actuators , 1997 .

[10]  E. C. Teague,et al.  Piezodriven 50‐μm range stage with subnanometer resolution , 1978 .

[11]  S H Chang,et al.  An ultra-precision XYtheta(Z) piezo-micropositioner. I. Design and analysis. , 1999, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[12]  Kee S. Moon,et al.  Optimal design of a flexure hinge based XYφ wafer stage , 1997 .

[13]  Kee-Bong Choi Kinematic analysis and optimal design of 3-PPR planar parallel manipulator , 2003 .

[14]  J. Tlusty,et al.  New NC Routines for Quality in Milling , 1990 .