Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulation

The posterior tibial nerves of 18 rabbits were intraneurally implanted with coiled wire electrodes for up to 9 weeks to evaluate their usefulness for neuromuscular electrical stimulation. In one group an electrode was implanted and removed in one leg while the other leg was chronically implanted. A second group was chronically implanted without electrical stimulation in one leg and implanted with cyclical electrical stimulation applied through the electrode in the other leg. No significant changes in nerve conduction velocities between the time of implantation and up to 9 weeks post-implantation were observed in either the stimulated or the non-stimulated nerves. Little change in motor current threshold was observed beyond 10 days postimplantation. The nerves showed little or no histologic demyelination or denervation in most specimens, although in about 40% of the nerves, a bulbous formation of connective tissue was observed at electrode entry and exit sites with some demyelination in these regions. The spinal cords showed no histologic abnormalities in either group. The gastrocenemius and soleus muscles showed only occasional signs of denervation. One cat was implanted in both the posterior tibial and peroneal nerves of each leg for a 4-year period. Threshold current showed very little change during the implantation period. The nerves showed minimal focal demyelination at the electrode site and the muscles showed normal fibers.

[1]  C. W. Caldwell,et al.  A Percutaneous Wire Electrode for Chronic Research Use , 1975, IEEE Transactions on Biomedical Engineering.

[2]  H. J. Crow,et al.  Toxic effects of intra-cerebral electrodes , 1966, Medical and biological engineering.

[3]  Experience with implanted electrodes at Rancho Los Amigos Hospital. , 1977, Applied neurophysiology.

[4]  G. E. Loeb,et al.  Implantable electrical and mechanical interfaces with nerve and muscle , 2006, Annals of Biomedical Engineering.

[5]  L A Bullara,et al.  Electrical stimulation of the brain. III. The neural damage model. , 1975, Surgical neurology.

[6]  W G Holcomb,et al.  Long‐Term Ventilatory Support by Diaphragm Pacing in Quadriplegia , 1976, Annals of surgery.

[7]  J. Thomas Mortimer,et al.  Intramuscular electrical stimulation: Tissue damage , 2006, Annals of Biomedical Engineering.

[8]  J. Reswick,et al.  Functional electrical stimulation : applications in neural prostheses , 1977 .

[9]  J. T. McFadden Metallurgical principles in neurosurgery. , 1969, Journal of neurosurgery.

[10]  M. Phelps,et al.  Ventilatory support of the quadriplegic patient with respiratory paralysis by diaphragm pacing. , 1980, The Surgical clinics of North America.

[11]  V. Mooney,et al.  Advances in percutaneous electrode systems. , 1976, Biomaterials Medical Devices and Artificial Organs.

[12]  R. Waters,et al.  Experimental correction of footdrop by electrical stimulation of the peroneal nerve. , 1975, The Journal of bone and joint surgery. American volume.

[13]  E. Manuelidis,et al.  Histopathological changes produced by implanted electrodes in cat brains; comparison with histopathological changes in human and experimental puncture wounds. , 1957, Journal of neurosurgery.

[14]  Dr. D. R. McNeal,et al.  Selective activation of muscles using peripheral nerve electrodes , 2006, Medical and Biological Engineering and Computing.

[15]  C J De Luca,et al.  Voluntary nerve signals from severed mammalian nerves: long-term recordings. , 1976, Science.

[16]  F. Terry Hambrecht,et al.  Applications of neural control in humans , 2006, Annals of Biomedical Engineering.

[17]  G Lundborg,et al.  Effects of stretching the tibial nerve of the rabbit. A preliminary study of the intraneural circulation and the barrier function of the perineurium. , 1973, The Journal of bone and joint surgery. British volume.

[18]  R. Pudenz,et al.  Electrical control of facial pain. , 1967, American journal of surgery.

[19]  M C Wetzel,et al.  Experimental performance of steel and platinum electrodes with chronic monophasic stimulation of the brain. , 1969, Journal of neurosurgery.

[20]  W J MACINTYRE,et al.  The production of brain lesions with electric currents. II. Bidirectional currents. , 1960, Journal of neurosurgery.

[21]  J. B. Reswick,et al.  Electrical Activation of Skeletal Muscle by Sequential Stimulation , 1970 .

[22]  Robert L. White,et al.  Microelectronics and neural prostheses , 2006, Annals of Biomedical Engineering.

[23]  Robert L. White,et al.  An Evaluation of the Resistance to Electrolysis of Metals for Use in Biostimulation Microprobes , 1974 .