Followup calculations for the UVAR LEU conversion
暂无分享,去创建一个
The UVAR reactor was successfully converted to LEU fuel in April 1994. Void coefficient measurements were made on the 4-by-4 fully-graphite-reflected LEU-1 core configuration, and an isothermal temperature coefficient measurement was made on the operational 4-by-5 partially-graphite-reflected LEU-2 core configuration. Both of these experiments have now been modeled in their critical configurations using the 3DBUM code. The LEU cores were also modeled using the Monte Carlo code MCNP in order to obtain a neutron/gamma source for BNCT filter design calculations. Advanced BNCT filters have been evaluated using both MCNP and the discrete ordinates code DORT. The results indicate that the UVAR would be an ideal source for the BNCT treatment of brain tumors.