Skin blood flow changes, measured by laser Doppler flowmetry, in the first week after birth.

Changes in forehead skin blood flow were determined in 17 healthy, term newborns, using a fiberless diode laser Doppler flow meter (Diodopp). Measurements were carried out three times on each infant, at postnatal ages of 16.8 +/- 7.4 h, 58.9 +/- 6.2 h and 121.5 +/- 14.2 h (mean +/- S.D.), respectively. Skin blood flow, respiration, heart rate and skin temperature were recorded simultaneously, while the newborns were asleep. During the recordings, the behavioural state of the newborns was observed and environmental temperature and humidity were kept constant. Postocclusive hyperaemia of the skin blood flow was obtained by pressing the laser Doppler probe against the skull for 30 or 60 s. The following parameters changed significantly between the first and third measurements (t-test for paired samples): the basal skin blood flow during active and quiet sleep decreased, the average decrease being 29.4% (P = 0.002) and 25.9% (P = 0.01), respectively; skin blood flow during postocclusive hyperaemia also changed: the time taken to reach maximum hyperaemia increased from 17.3 to 22.7 s (P = 0.01), while the halftime recovery increased from 46.1 to 57.1 s (P = 0.02). The changes in skin blood flow between the first and second measurements and between the second and third measurements did not reach the level of statistical significance.

[1]  T. Tenland On laser Doppler flowmetry : methods and microvascular applications , 1982 .

[2]  Oberg Pa,et al.  Laser-Doppler flowmetry. , 1990, Critical reviews in biomedical engineering.

[3]  P. Kolari Penetration of unfocused laser light into the skin , 2004, Archives of Dermatological Research.

[4]  Paul Y. K. Wu,et al.  Peripheral Blood Flow in the Neonate. 1. Changes in Total, Skin, and Muscle Blood Flow with Gestational and Postnatal Age , 1980, Pediatric Research.

[5]  Gert E. Nilsson,et al.  Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow , 1980, IEEE Transactions on Biomedical Engineering.

[6]  R L Bowman,et al.  Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. , 1977, The American journal of physiology.

[7]  R. Zetterström,et al.  Capillary Blood Cell Velocity in Full-Term Infants as Determined in Skin by Videophotometric Microscopy , 1988, Pediatric Research.

[8]  O. Celander,et al.  CIRCULATORY ADAPTATION IN THE THERMOREGULATION OF FULLTERM AND PREMATURE NEWBORN INFANTS , 1971, Acta paediatrica Scandinavica.

[9]  O. Celander,et al.  Reactive Hyperaemia in the Foot and Calf of the Newborn Infant , 1962, Acta paediatrica.

[10]  A. C. Guyton,et al.  Failure of recovery from reactive hyperemia in the absence of oxygen. , 1966, The American journal of physiology.

[11]  John A. Parrish,et al.  Optical Properties of Human Skin , 1982 .

[12]  H. Prechtl,et al.  The behavioural states of the newborn infant (a review). , 1974, Brain research.

[13]  A. Kurban,et al.  THE DEVELOPMENT OF THE CUTANEOUS MICROVASCULAR SYSTEM IN THE NEWBORN , 1970 .

[14]  R. W. Wunderlich,et al.  Laser doppler blood flow meter and optical plethysmograph , 1980 .

[15]  O. Henriksen,et al.  Excess cumulative blood flow and repayment during reactive hyperemia in human cutaneous tissue. , 1980, Acta physiologica Scandinavica.

[16]  R. Nossal,et al.  Model for laser Doppler measurements of blood flow in tissue. , 1981, Applied optics.

[17]  M Intaglietta,et al.  Quantitation of rhythmic diameter changes in arterial microcirculation. , 1984, The American journal of physiology.

[18]  J. Greve,et al.  Forehead Skin Blood Flow in Normal Neonates during Active and Quiet Sleep, Measured with a Diode Laser Doppler Instrument , 1988, Acta paediatrica Scandinavica.