Ultrasound imaging to assess inter- and intra-fraction motion during bladder radiotherapy and its potential as a verification tool.

AIMS Organ motion is the principle source of error in bladder cancer radiotherapy. The aim of this study was to evaluate ultrasound bladder volume measurement as a surrogate measure of organ motion during radiotherapy: (1) to assess inter- and intra-fraction bladder variation and (2) as a potential treatment verification tool. MATERIALS AND METHODS Twenty patients receiving radical radiotherapy for bladder cancer underwent post-void ultrasound bladder volume measurement at the time of radiotherapy treatment planning (RTP), and immediately before (post-void) and after receiving daily fractions. RESULTS Ultrasound bladder volume measurement was found to be a simple and acceptable method to estimate relative bladder volume changes. Six patients showed significant changes to post-void bladder volume over the treatment course (P<0.05). The mean inter-fraction post-void bladder volume of five patients exceeded their RTP ultrasound bladder volume by more than 50%. Intra-fraction bladder volume increased on 275/308 (89%) assessed fractions, with the mean intra-fraction volume increases of seven patients exceeding their RTP ultrasound bladder volume by more than 50%. CONCLUSIONS Both day-to-day bladder volume variation and bladder filling during treatment should be considered in RTP and delivery. Ultrasound may provide a practical daily verification tool by: supporting volume limitation as a method of treatment margin reduction; allowing detection of patients who may require interventions to promote bladder reproducibility; and identifying patients with prominent volume changes for the selective application of more advanced adaptive/image-guided radiotherapy techniques.

[1]  V. Khoo,et al.  X-ray volumetric imaging in image-guided radiotherapy: the new standard in on-treatment imaging. , 2006, International journal of radiation oncology, biology, physics.

[2]  Simon Hooper,et al.  Variability of bladder filling in patients receiving radical radiotherapy to the prostate. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Ali Amer,et al.  Online adaptive radiotherapy of the bladder: small bowel irradiated-volume reduction. , 2006, International journal of radiation oncology, biology, physics.

[4]  B. Skjoldbye,et al.  Urinary Bladder Volume Measurements: Comparison of Three Ultrasound Calculation Methods , 2002, Scandinavian journal of urology and nephrology.

[5]  L. Muren,et al.  Organ motion, set-up variation and treatment margins in radical radiotherapy of urinary bladder cancer. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  J. Logue,et al.  Radiation therapy for muscle-invasive bladder cancer: treatment planning and delivery. , 2005, Clinical oncology (Royal College of Radiologists (Great Britain)).

[7]  R. Cowan,et al.  Bladder movement during radiation therapy for bladder cancer: implications for treatment planning. , 1997, International journal of radiation oncology, biology, physics.

[8]  C. Pelizzari,et al.  Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. , 1995, International journal of radiation oncology, biology, physics.

[9]  M van Herk,et al.  Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer. , 1995, International journal of radiation oncology, biology, physics.

[10]  K. Matre,et al.  Volume estimation of small phantoms and rat kidneys using three-dimensional ultrasonography and a position sensor. , 2004, Ultrasound in medicine & biology.

[11]  J M Wilkinson,et al.  Geometric uncertainties in radiotherapy. , 2004, The British journal of radiology.

[12]  R. Buchanan,et al.  An audit and evaluation of bladder movements during radical radiotherapy. , 1998, Clinical oncology (Royal College of Radiologists (Great Britain)).

[13]  Christopher J Moore,et al.  Assessment of bladder motion for clinical radiotherapy practice using cine-magnetic resonance imaging. , 2009, International journal of radiation oncology, biology, physics.

[14]  A. Horwich,et al.  Evaluating inter-fractional changes in volume and position during bladder radiotherapy and the effect of volume limitation as a method of reducing the internal margin of the planning target volume. , 2008, Clinical oncology (Royal College of Radiologists (Great Britain)).

[15]  G. Morelli,et al.  Measurements of urinary bladder volume: comparison of five ultrasound calculation methods in volunteers. , 2005, Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica.

[16]  P. Ramsden,et al.  Accuracy and repeatability of bladder volume measurement using ultrasonic imaging. , 1986, The Journal of urology.

[17]  M. Hulshof,et al.  Influence of bladder and rectal volume on spatial variability of a bladder tumor during radical radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[18]  W G Jones,et al.  Changes in target volume during radiotherapy treatment of invasive bladder carcinoma. , 1993, Clinical oncology (Royal College of Radiologists (Great Britain)).

[19]  G. Poston,et al.  The accuracy of ultrasound in the measurement of changes in bladder volume. , 1983, British journal of urology.

[20]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[21]  J. Pouliot,et al.  Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[22]  R. Millard,et al.  The accuracy of portable ultrasound scanning in the measurement of residual urine volume. , 1994, The Journal of urology.

[23]  N. Dudley,et al.  Clinical agreement between automated and calculated ultrasound measurements of bladder volume. , 2003, The British journal of radiology.

[24]  J. Logue,et al.  Radiation therapy for muscle-invasive bladder cancer: treatment planning and delivery in the 21st century. , 2005, Seminars in radiation oncology.

[25]  M. V. van Herk,et al.  Tumor motion and deformation during external radiotherapy of bladder cancer. , 2006, International journal of radiation oncology, biology, physics.

[26]  Joos V Lebesque,et al.  Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer. , 2003, International journal of radiation oncology, biology, physics.

[27]  J. Holmes,et al.  Ultrasonic studies of the bladder. , 1967, The Journal of urology.

[28]  James Wylie,et al.  X-ray volume imaging in bladder radiotherapy verification. , 2006, International journal of radiation oncology, biology, physics.

[29]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[30]  R. Ryall,et al.  The estimation of bladder volume by sonocystography. , 1983, The Journal of urology.

[31]  H. von der Maase,et al.  Impact of changes in bladder and rectal filling volume on organ motion and dose distribution of the bladder in radiotherapy for urinary bladder cancer. , 2004, International journal of radiation oncology, biology, physics.

[32]  R Miralbell,et al.  Radiotherapy of bladder cancer: relevance of bladder volume changes in planning boost treatment. , 1998, International journal of radiation oncology, biology, physics.