A novel tool for the prediction of tablet sticking during high speed compaction

During tableting, capping is a problem of cohesion while sticking is a problem of adhesion. Sticking is a multi-composite problem; causes are either material or machine related. Nowadays, detecting such a problem is a pre-requisite in the early stages of development. The aim of our study was to investigate sticking by radial die-wall pressure monitoring guided by compaction simulation. This was done by using the highly sticking drug; Mefenamic acid (MA) at different drug loadings with different fillers compacted at different pressures and speeds. By increasing MA loading, we found that viscoelastic fillers showed high residual radial pressure after compaction while plastic/brittle fillers showed high radial pressure during compaction, p < 0.05. Visually, plastic/brittle fillers showed greater tendencies for adhesion to punches than viscoelastic fillers while the later showed higher tendencies for adhesion to the die-wall. This was confirmed by higher values of axial stress transmission for plastic/brittle than viscoelastic fillers (higher punch surface/powder interaction), and higher residual die-wall and ejection forces for viscoelastic than plastic/brittle fillers, p < 0.05. Take-off force was not a useful tool to estimate sticking due to cohesive failure of the compacts. Radial die-wall pressure monitoring is suggested as a robust tool to predict sticking.

[1]  O. Pillai,et al.  Solid-state characterization of mefenamic acid. , 2004, Journal of pharmaceutical sciences.

[2]  P. Schmidt,et al.  A novel method for the detection of sticking of tablets. , 1999, Pharmaceutical development and technology.

[3]  Robert Erck,et al.  Modeling of adhesion in tablet compression--I. Atomic force microscopy and molecular simulation. , 2003, Journal of pharmaceutical sciences.

[4]  J. Newton,et al.  Investigation of applied compression on the adhesion of powders to a substrate surface , 1991 .

[5]  J. Visser,et al.  Van der Waals and other cohesive forces affecting powder fluidization , 1989 .

[6]  F. Sadeghi,et al.  Crystal Habit Modifications of Ibuprofen and Their Physicomechanical Characteristics , 2001, Drug development and industrial pharmacy.

[7]  A Otsuka,et al.  [Adhesive properties and related phenomena for powdered pharmaceuticals]. , 1998, Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan.

[8]  P. Schmidt,et al.  Factors Influencing Capping and Cracking of Mefenamic Acid Tablets , 2000, Drug development and industrial pharmacy.

[9]  J. Newton,et al.  Effect of temperature on particulate solid adhesion to a substrate surface , 1992 .

[10]  N. Harnby,et al.  Moisture bonding in powders , 1978 .

[11]  Tony Howes,et al.  Stickiness measurement techniques for food powders: a review , 2004 .

[12]  Jianhong Jennifer Wang Modeling of adhesion in tablet compression , 2002 .

[13]  R C Rowe,et al.  The effect of punch velocity on the compaction of a variety of materials , 1985, The Journal of pharmacy and pharmacology.

[14]  H. Sunada,et al.  Measurement and evaluation of the adhesive force between particles by the direct separation method. , 2003, Journal of pharmaceutical sciences.

[15]  J. Mcginity,et al.  Adhesion of polymeric films to pharmaceutical solids. , 1999, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[16]  H. Takebayashi,et al.  Measurement of the Adhesive Force of Fine Particles on Tablet Surfaces and Method of Their Removal , 2000, Drug development and industrial pharmacy.

[17]  J. Staniforth,et al.  A study of powder adhesion to metal surfaces during compression of effervescent pharmaceutical tablets , 1986, The Journal of pharmacy and pharmacology.

[18]  M. Roberts,et al.  Effect of lubricant type and concentration on the punch tip adherence of model ibuprofen formulations , 2004, The Journal of pharmacy and pharmacology.

[19]  J. Newton,et al.  The influence of the time of application of contact pressure onparticle adhesion to a substrate surface , 1993 .

[20]  Colleen E. Ruegger,et al.  The Effect of Compression and Decompression Speed on the Mechanical Strength of Compacts , 2000, Pharmaceutical development and technology.

[21]  P York,et al.  Particle slippage and rearrangement during compression of pharmaceutical powders , 1978, The Journal of pharmacy and pharmacology.

[22]  M. H. Rubinstein,et al.  Tablet lubricants I. Theory and modes of action , 1981 .

[23]  H. Leuenberger,et al.  Influence of Loading Volume of Mefenamic Acid on Granules and Tablet Characteristics Using a Compaction Simulator , 2008, Pharmaceutical development and technology.

[24]  L. Augsburger,et al.  Adhesion of Tablets in a Rotary Tablet Press I. Instrumentation and Preliminary Study of Variables Affecting Adhesion , 1980 .

[25]  P. Darcy,et al.  Water mobility in amorphous lactose below and close to the glass transition temperature , 1996 .

[26]  E. Shotton,et al.  The effect of some binding agents on the mechanical properties of granules and their compression characteristics , 1977, The Journal of pharmacy and pharmacology.

[27]  L. Augsburger,et al.  Adhesion of Tablets in a Rotary Tablet Press II. Effects of Blending Time, Running Time, and Lubricant Concentration , 1982 .

[28]  James Q. Feng Adhesive Contact of Elastically Deformable Spheres: A Computational Study of Pull-Off Force and Contact Radius. , 2001, Journal of colloid and interface science.

[29]  K. Morris,et al.  Modeling of adhesion in tablet compression. II. Compaction studies using a compaction simulator and an instrumented tablet press. , 2004, Journal of pharmaceutical sciences.

[30]  D. N. Travers,et al.  A Computer Aided Investigation on Strain Movements in Compacts Under Constant Stress Within the Die , 1983 .

[31]  P. Schmidt,et al.  Some Physicochemical Properties of Mefenamic Acid , 2000, Drug development and industrial pharmacy.

[32]  F Podczeck,et al.  Investigations into the reduction of powder adhesion to stainless steel surfaces by surface modification to aid capsule filling. , 1999, International journal of pharmaceutics.

[33]  Eric Doelker,et al.  Benefits of die-wall instrumentation for research and development in tabletting. , 2004, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[34]  G. Betz,et al.  Study of radial die-wall pressure changes during pharmaceutical powder compaction , 2011, Drug development and industrial pharmacy.

[35]  R. Rowe,et al.  The effect of the relationship between punch velocity and particle size on the compaction behaviour of materials with varying deformation mechanisms , 1986, The Journal of pharmacy and pharmacology.

[36]  T. Jahn,et al.  Press Chamber Coating as External Lubrication for High Speed Rotary Presses: Lubricant Spray Rate Optimization , 2005, Drug development and industrial pharmacy.

[37]  John N. Staniforth,et al.  Aspects of Pharmaceutical Tribology , 1989 .

[38]  Giulia Bonacucina,et al.  Stress relaxation test for the characterization of the viscoelasticity of pellets. , 2007, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[39]  A. D. Woolfson,et al.  Non-invasive monitoring of percutaneous local anaesthesia using laser-Doppler velocimetry , 1989 .

[40]  I. Saracovan,et al.  Measurement of the surface energy of lubricated pharmaceutical powders by inverse gas chromatography. , 2006, International journal of pharmaceutics.

[41]  K. Danjo,et al.  Effect of Temperature on the Sticking of Low Melting Point Materials , 1993 .

[42]  Jm Newton,et al.  Influence of particle size on the adhesion behaviour of powders, after application of an initial press-on force , 1992 .