Atraumatic CBF measurement with the scintillation camera. Comparison with intracarotid rCBF values.

A scintillation camera connected to a dedicated computer system was employed for atraumatic CBF measurements in 43 patients after intravenous injection of 35 to 55 mCi 133Xe in saline solution. To validate this method results were compared to flow values in the same patients measured after intracarotid Xe injection. While the correlation between i.c. and i.v. values was not satisfactory when a high resolution collimator was used, a high sensitivity collimator improved count rates and yielded CBF values after i.v. in agreement with those from i.c. studies. For mean hemispheric flow, the correlation coefficient between the methods was 0.93 and the standard deviation of the i.v. value for a given i.c. value was 2.93. The correlation coefficients for 13 regions were between 0.55 and 0.85. These correlation coefficients are comparable to those obtained with multidetector equipment. Ischemic regions could be accurately detected, and the flow values in these areas were significantly related (r = 0.81). Values in 6 healthy volunteers were in the normal range reported by other investigators. One disadvantage of the camera is that measurements are restricted to one hemisphere, but selection of recording areas is not limited to the position of single probes and may be changed during analysis of the data permitting analysis of flow in irregularly-shaped, pathologically-perfused regions. The results indicate that the scintillation camera is a useful tool for clinical rCBF studies.

[1]  L. Symon,et al.  An intravenous 133Xenon clearance technique for measuring cerebral blood flow , 1979, Journal of the Neurological Sciences.

[2]  S. Bentin,et al.  Bihemispheric decreases of regional cerebral blood flow in dementia: Correlation with age‐matched normal controls , 1978, Annals of neurology.

[3]  L. Mchenry,et al.  Xenon-133 Inhalation Method for Regional Cerebral Blood Flow Measurements: Normal Values and Test-Retest Results , 1978, Stroke.

[4]  F. Sakai,et al.  Improved Method for Noninvasive Measurement of Regional Cerebral Blood Flow by 133Xenon Inhalation Part I: Description of Method and Normal Values Obtained in Healthy Volunteers , 1978, Stroke.

[5]  E M Wilson,et al.  133Xenon Inhalation Method Analysis of Reproducibility: Some of Its Physiological Implications , 1977, Stroke.

[6]  D. Wyper,et al.  Two minute slope inhalation technique for cerebral blood flow measurement in man. 1. Method. , 1976, Journal of neurology, neurosurgery, and psychiatry.

[7]  D. Wyper,et al.  Two minute slope inhalation technique for cerebral blood flow measurement in man. 2. Clinical appraisal. , 1976, Journal of neurology, neurosurgery, and psychiatry.

[8]  J. Risberg,et al.  Regional Cerebral Blood Flow by 133Xenon Inhalation: Preliminary Evaluation of an Initial Slope Index in Patients with Unstable Flow Compartments , 1975, Stroke.

[9]  T. Sundt,et al.  Blood Flow Measurements and the “Look Through” Artifact in Focal Cerebral Ischemia , 1975, Stroke.

[10]  B L Holman,et al.  Regional cerebral blood flow with the Anger camera. , 1972, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  A. Capon,et al.  [Use of the gamma camera for measurement of regional cerebral blood flow, using radioactive xenon]. , 1972, Bruxelles medical.

[12]  W. Heiss,et al.  Technical considerations in the use of a gamma camera 1,600-channel analyzer system for the measurement of regional cerebral blood flow. , 1972, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  E. J. Potchen,et al.  A MEANS FOR THE SCINTIGRAPHIC IMAGING OF REGIONAL BRAIN DYNAMICS. REGIONAL CEREBRAL BLOOD FLOW AND REGIONAL CEREBRAL BLOOD VOLUME. , 1969 .

[14]  E. Alberti,et al.  [Estimation of regional cerebral blood flow with the gamma-camera (author's transl)]. , 1977, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[15]  H. Thompson,et al.  Regional cerebral blood flow estimated by /sup 133/Xe inhalation , 1975 .

[16]  G. Austin,et al.  Intravenous Isotope Injection Method of Cerebral Blood Flow Measurement: Accuracy and Reproducibility , 1975 .

[17]  W. Heiss,et al.  Die Verwendung von Gamma-Kamera und Vielkanalspeicher zur Messung der gesamten und regionalen Hirndurchblutung , 1968, Nuklearmedizin.