The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage.

This study investigates the accuracy and reliability of a novel handheld indentation system designed to ascertain the dynamic biomechanical properties of articular cartilage. A series of standard elastomers were assessed with both the handheld indentation system and a bench-top dynamic indentation system to assess the accuracy of the instrument. Interoperator and intraoperator experiments were undertaken to investigate the reliability of the system when used by an individual operator and by five different operators. Intraclass coefficients (Rho) were derived using a random effects model. The system was then used to ascertain the topographical variation in the shear moduli and phase lag of articular cartilage across normal ovine tibial plateaux. The system was shown to be highly accurate (R2 = 0.97), and had excellent reliability when measuring the dynamic shear modulus of articular cartilage (interoperator Rho = 0.75, intraoperator Rho = 0.79). Measurement of static shear modulus was less reliable (interoperator Rho = 0.15, intraoperator Rho = 0.52), but may be improved by monitoring the load applied to the instrument by the operator. The instrument was used to differentiate between different regions of cartilage and generated a topographical map of an ovine tibial plateau. The cartilage located beneath the menisci was 200-500% stiffer than the cartilage that was not covered by the menisci, while the phase lag was almost constant (10+/-2 SD) over the entire tibial plateau. The system was shown to be an accurate and reliable tool for rapidly assessing the dynamic biomechanical properties of articular cartilage, while being small enough to be used arthroscopically.

[1]  M. Freeman,et al.  The determination of a creep modulus for articular cartilage from indentation tests of the human femoral head. , 1971, Journal of biomechanics.

[2]  V. Mow,et al.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments. , 1980, Journal of biomechanical engineering.

[3]  W C Hayes,et al.  Flow-independent viscoelastic properties of articular cartilage matrix. , 1978, Journal of biomechanics.

[4]  V C Mow,et al.  Viscoelastic shear properties of articular cartilage and the effects of glycosidase treatments , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  I Kiviranta,et al.  Indentation instrument for the measurement of cartilage stiffness under arthroscopic control. , 1995, Medical engineering & physics.

[6]  An experimental investigation of the use of random squeezing to determine the complex modulus of viscoelastic fluids , 1996 .

[7]  J. Arokoski,et al.  Softening of the lateral condyle articular cartilage in the canine knee joint after long distance (up to 40 km/day) running training lasting one year. , 1994, International journal of sports medicine.

[8]  E. Frank,et al.  Nondestructive detection of cartilage degeneration using electromechanical surface spectroscopy. , 1994, Journal of biomechanical engineering.

[9]  R. Appleyard,et al.  Biomechanical, histological and immunohistological studies of patellar cartilage in an ovine model of osteoarthritis induced by lateral meniscectomy. , 1999, Osteoarthritis and cartilage.

[10]  J. Fleiss,et al.  Statistical management of data in clinical research. , 1990, Critical reviews in oral biology and medicine : an official publication of the American Association of Oral Biologists.

[11]  B B Seedhom,et al.  The stiffness of normal articular cartilage and the predominant acting stress levels: implications for the aetiology of osteoarthrosis. , 1993, British journal of rheumatology.

[12]  H. J. Mankin,et al.  Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Articular Cartilage. Part I: Tissue Design and Chondrocyte-Matrix Interactions*† , 1997 .

[13]  H R Halperin,et al.  Hand-held, dynamic indentation system for measuring myocardial transverse stiffness. , 1996, Biomedical instrumentation & technology.

[14]  G A Ateshian,et al.  Biomechanics of diarthrodial joints: a review of twenty years of progress. , 1993, Journal of biomechanical engineering.

[15]  D. Roylance,et al.  Oscillatory compressional behavior of articular cartilage and its associated electromechanical properties. , 1981, Journal of biomechanical engineering.

[16]  C B Frank,et al.  The effect of cryopreservation on the biomechanical behavior of bovine articular cartilage , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  J H Dashefsky,et al.  Arthroscopic measurement of chondromalacia of patella cartilage using a microminiature pressure transducer. , 1987, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[18]  W. Hayes,et al.  A mathematical analysis for indentation tests of articular cartilage. , 1972, Journal of biomechanics.

[19]  B. Seedhom,et al.  Improved Techniques for Measuring the Indentation and Thickness of Articular Cartilage , 1989, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  J. R. Parsons,et al.  Articular cartilage preservation and storage. II. Mechanical indentation testing of viable, stored articular cartilage. , 1979, Arthritis and rheumatism.