Economic and environmental based operation strategies of a hybrid photovoltaic–microgas turbine trigeneration system

This study investigates the economic and environmental performance of a photovoltaic (PV) and microgas turbine trigeneration system (MGT-TGS) based hybrid energy system with various operation strategies. The hybrid system covers power, heating and cooling load of a selected building under a tropical region. A case of MGT-TGS without PV was also studied for comparison. Each system had an MGT with electrical output capacity of 30kW or 65kW as the core prime mover. Economic performance was analyzed using life cycle cost analysis and environmental performance was analyzed based on the actual emissions of MGT reported in literatures. It was found that all operation strategies can only generate Net Profit when subsidy for electricity was eliminated. Combination of photovoltaic and MGT-TGS with power-match operation strategy had the highest Net Profit and was the simplest hybrid system. This was mainly because this system did not require battery that has high cost. However, this system had low environmental performance especially when they are compared to a combined cycle gas turbine (CCGT) because larger MGTs in this system operated frequently under partial load. Operation strategy that had smaller MGT that operated under full load can still generate Net Profit but at lower degree because it needs larger PV and battery. However, it was the only operation strategy that can reduce all emissions even when compared to a CCGT. Thus, this is the best operation strategy when economic and environmental performance are fairly considered.

[1]  F. J. Wang,et al.  Economic feasibility of waste heat to power conversion , 2007 .

[2]  Alberto Coronas,et al.  Integration of absorption cooling systems into micro gas turbine trigeneration systems using biogas: Case study of a sewage treatment plant , 2009 .

[3]  Wenming Yang,et al.  Integrating renewable energy technologies to support building trigeneration – A multi-criteria analysis , 2012 .

[4]  Joshua M. Pearce Expanding Photovoltaic Penetration with Residential Distributed Generation from Hybrid Solar Photovoltaic Combined Heat and Power Systems , 2009 .

[5]  Pierluigi Mancarella,et al.  Emission characterization and evaluation of natural gas-fueled cogeneration microturbines and internal combustion engines , 2008 .

[6]  Masud Behnia,et al.  A study on the optimum arrangement of prime movers in small scale microturbine-based CHP systems , 2012 .

[7]  Lukas G. Swan,et al.  Improved performance of hybrid photovoltaic-trigeneration systems over photovoltaic-cogen systems including effects of battery storage , 2013 .

[8]  Shin'ya Obara Equipment arrangement planning of a fuel cell energy network optimized for cost minimization , 2007 .

[9]  Z. Zain,et al.  Hot and humid climate: prospect for thermal comfort in residential building , 2007 .

[10]  M. Tioursi,et al.  Power management strategy in the alternative energy photovoltaic/PEM Fuel Cell hybrid system , 2011 .

[11]  Fahad A. Al-Sulaiman,et al.  Development and assessment of integrating parabolic trough collectors with steam generation side of gas turbine cogeneration systems in Saudi Arabia , 2015 .

[12]  Lu Aye,et al.  Technical feasibility and financial analysis of hybrid wind–photovoltaic system with hydrogen storage for Cooma , 2005 .

[13]  M. Woodhouse,et al.  Residential, Commercial, and Utility-Scale Photovoltaic (PV) System Prices in the United States: Current Drivers and Cost-Reduction Opportunities , 2012 .

[14]  Joshua M. Pearce,et al.  Dispatch Strategy and Model for Hybrid Photovoltaic and Trigeneration Power Systems , 2011 .

[15]  Firdaus Basrawi,et al.  Performance Evaluation of Micro Gas Turbine Cogeneration System at Sewage Treatment Plant : Performance Analysis under Various Regions with Different Annual Average Temperature(Thermal Engineering) , 2010 .

[16]  Tetsu Kubota,et al.  A Field Survey on Usage of Air-conditioners and Windows in Terraced House Areas in Johor Bahru City , 2006 .

[17]  Neil Strachan,et al.  Emissions from distributed vs. centralized generation: the importance of system performance , 2006 .

[18]  Lisa Branchini,et al.  Optimal sizing of grid-independent hybrid photovoltaic–battery power systems for household sector , 2014 .

[19]  Alojz Poredoš,et al.  Economics of a trigeneration system in a hospital , 2006 .

[20]  Teuku Meurah Indra Mahlia,et al.  Life cycle cost analysis of fuel cell based cogeneration system for residential application in Malaysia , 2011 .

[21]  Masud Behnia,et al.  Impact of carbon tax on internal combustion engine size selection in a medium scale CHP system , 2011 .

[22]  Shin'ya Obara,et al.  Compound microgrid installation operation planning of a PEFC and photovoltaics with prediction of electricity production using GA and numerical weather information , 2009 .

[23]  Shin'ya Obara,et al.  Energy Supply Characteristics of a Combined Solar Cell and Diesel Engine System with a Prediction Algorithm for Solar Power Generation , 2010 .

[24]  J. M. Ngundam,et al.  Modelling of solar/diesel/battery hybrid power systems for far-north Cameroon , 2007 .

[25]  Shin'ya Obara,et al.  Power generation efficiency of photovoltaics and a SOFC-PEFC combined micro-grid with time shift utilization of the SOFC exhaust heat , 2010, The 2010 International Power Electronics Conference - ECCE ASIA -.

[26]  Teuku Meurah Indra Mahlia,et al.  Techno-economic analysis of an optimized photovoltaic and diesel generator hybrid power system for remote houses in a tropical climate. , 2013 .

[27]  Luai M. Al-Hadhrami,et al.  Study of a solar PV–diesel–battery hybrid power system for a remotely located population near Rafha, Saudi Arabia , 2010 .

[28]  Firdaus Basrawi,et al.  Effect of ambient temperature on the performance of micro gas turbine with cogeneration system in cold region , 2011 .

[29]  Francesco Castelli-Dezza,et al.  Control strategies and configurations of hybrid distributed generation systems , 2012 .

[30]  A. S. Mokhtar,et al.  Optimal green energy management for island resorts in Malaysia. , 2013 .

[31]  Teuku Meurah Indra Mahlia,et al.  Design of an optimized photovoltaic and microturbine hybrid power system for a remote small community: Case study of Palestine , 2013 .

[32]  Shin'ya Obara,et al.  Fuel Reduction Effect of the Solar Cell and Diesel Engine Hybrid System with a Prediction Algorithm of Solar Power Generation , 2008 .

[33]  Shin'ya Obara,et al.  Theoretical analysis of performance of a micro gas turbine co/trigeneration system for residential buildings in a tropical region , 2013 .

[34]  Jiangjiang Wang,et al.  An improved operation strategy of combined cooling heating and power system following electrical load , 2015 .

[35]  Takanobu Yamada,et al.  Analysis of the performances of biogas-fuelled micro gas turbine cogeneration systems (MGT-CGSs) in middle- and small-scale sewage treatment plants: Comparison of performances and optimization of MGTs with various electrical power outputs , 2012 .

[36]  Brian Vad Mathiesen,et al.  The role of district heating in future renewable energy systems , 2010 .

[37]  A. Pesaran,et al.  PHEV/EV Li-Ion Battery Second-Use Project, NREL (National Renewable Energy Laboratory) (Poster) , 2010 .

[38]  Ahmad Pesaran,et al.  NREL's PHEV/EV Li-Ion Battery Secondary-Use Project , 2010 .

[39]  M. M. Armstrong,et al.  Control strategies and cycling demands for Li-ion storage batteries in residential micro-cogeneration systems , 2015 .

[40]  Caisheng Wang,et al.  Unit sizing and cost analysis of stand-alone hybrid wind/PV/fuel cell power generation systems , 2006 .