Non-invasive Estimation of Cardiac Output in Mechanically Ventilated Patients: A Prolonged Expiration Method

A non-invasive method for the estimation of cardiac output in mechanically ventilated patients is described. The method is based on prolonged expiration, and relies on measurement of gas concentrations and flow rate. A pneumatic system, with an ad hoc designed orifice resistance, has been made and experimentally characterized to adapt the breathing circuit to this application. Cardiac output is calculated using two algorithms and the results are compared with the ones obtained by thermodilution. To this purpose, we prospectively enrolled twenty mechanically ventilated patients, who had undergone cardiac surgery, and both algorithms show good correlation with thermodilution (R > 0.8). The application of the first algorithm gave mean cardiac output values slightly lower than those obtained by thermodilution (−6%), while the application of the second algorithm gave higher values (+30%). Difference standard deviations between paired measurements is 0.72 L min−1 for the first algorithm and 1.07 L min−1 for the second one. Standard deviation obtained by the application of the first algorithm is slightly lower than those relative to other minimally invasive techniques. Through prolonged expiration, and standardization and automation of the procedure on mechanically ventilated patients, the proposed system allows to obtain a non-invasive estimation of cardiac output.

[1]  G. Hedenstierna,et al.  A new method for noninvasive bedside determination of pulmonary blood flow , 1980, Medical and Biological Engineering and Computing.

[2]  B Pohl,et al.  Comparison of invasive and less‐invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model , 2006, European journal of anaesthesiology.

[3]  L. Critchley,et al.  A Meta-Analysis of Studies Using Bias and Precision Statistics to Compare Cardiac Output Measurement Techniques , 1999, Journal of Clinical Monitoring and Computing.

[4]  J. Grønlund,et al.  Repeatability of the single-breath method for estimation of pulmonary blood-flow: comparison among four data-reduction procedures. , 1986, Clinical physiology.

[5]  H. Larsson,et al.  Pulmonary blood flow determination with selective rebreathing of CO2. , 1985, Clinical physiology.

[6]  A. Lerner,et al.  Cardiac Output Monitoring: Is There a Gold Standard and How Do the Newer Technologies Compare? , 2010, Seminars in cardiothoracic and vascular anesthesia.

[7]  N. Gravenstein,et al.  Measurement of cardiac output before and after cardiopulmonary bypass: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. , 2004, Journal of cardiothoracic and vascular anesthesia.

[8]  S. Faddy Cardiac Output, Fick Technique for , 2006 .

[9]  B. Sohrab,et al.  A continuous cardiac output computer based on thermodilution principles , 2006, Annals of Biomedical Engineering.

[10]  B. Wranne,et al.  Single-breath method of measuring cardiac output--a reevaluation. , 1972, Journal of applied physiology.

[11]  B. Österlund,et al.  Pulmonary Blood Flow (Cardiac Output) and the Effective Lung Volume Determined from a Short Breath Hold Using the Differential Fick Method , 2002, Journal of Clinical Monitoring and Computing.

[12]  H Rahn,et al.  Estimation of true venous and arterial PCO2 by gas analysis of a single breath. , 1966, Journal of applied physiology.

[13]  Jerry M. Calkins,et al.  Cardiac output measurements. A review of current techniques and research , 2006, Annals of Biomedical Engineering.

[14]  G. Mchardy The relationship between the differences in pressure and content of carbon dioxide in arterial and venous blood. , 1967, Clinical science.

[15]  D. Thompson,et al.  Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method , 2008, Journal of clinical monitoring and computing.

[16]  P. do Nascimento,et al.  Maintaining Tissue Perfusion in High-Risk Surgical Patients: A Systematic Review of Randomized Clinical Trials , 2011, Anesthesia and analgesia.

[17]  Sergio Silvestri,et al.  Influence of ventilatory settings on indirect calorimetry in mechanically ventilated patients , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  McHardy Gj The relationship between the differences in pressure and content of carbon dioxide in arterial and venous blood. , 1967, Clinical science.

[19]  Philip J Peyton,et al.  Minimally Invasive Measurement of Cardiac Output during Surgery and Critical Care: A Meta-analysis of Accuracy and Precision , 2010, Anesthesiology.

[20]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[21]  M P Hlastala,et al.  A model of fluctuating alveolar gas exchange during the respiratory cycle. , 1972, Respiration physiology.

[22]  Sergio Silvestri,et al.  Uncertainty evaluation of a calibration method for metabolic analyzer in mechanical ventilation , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[23]  R. Hainsworth,et al.  Evaluation of a method for estimating cardiac output from a single breath in humans. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[24]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[25]  Michael B. Jaffe,et al.  Partial CO2 Rebreathing Cardiac Output – Operating Principles of the NICO™ System , 1999, Journal of Clinical Monitoring and Computing.

[26]  S. Godfrey Manipulation of the indirect Fick principle by a digital computer program for the calculation of exercise physiology results. , 1970, Respiration; international review of thoracic diseases.

[27]  M. Sackner Measurement of Cardiac Output by Alveolar Gas Exchange , 2011 .

[28]  R. Hughson,et al.  Comparison of cardiac output during exercise by single-breath and CO2-rebreathing methods. , 1985, Journal of applied physiology.