Theory and application of dynamic aging for life estimation in machine insulation

After a brief discussion on possible on-line indicators of aging, this paper presents a concept of dynamic aging theory (DAT). Based on the philosophy of a DAT, a dynamic multistress aging model is proposed. Necessary DAT formulation and software have been developed for testing the model against laboratory aging data. In this study, dynamic stagnation voltage (DSV), a derived partial discharge parameter, and the groundwall insulation response to a traveling acoustic wave have been found to be the most appropriate parameters for assessment of remaining insulation machine life. This approach is shown to be a meaningful and practical solution to a very complex problem. Although this study is in its initial stage, it does show significant promise as an on-line tool for dynamically predicting remaining life based on DAT and other appropriate feedback measures.

[1]  S. N. Moorching,et al.  Multi-factor ageing of stator coil insulation of HV machines and degree of correlation among non-destructive test parameters , 1993, Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93).

[2]  G. Montanari,et al.  Combined electro-thermo-mechanical model for life prediction of electrical insulating materials , 1995, Proceedings of 1995 Conference on Electrical Insulation and Dielectric Phenomena.

[3]  T. Okamoto,et al.  Analysis of q-n and φ-q characteristics of partial discharge in several electrode systems , 1980, 1980 IEEE International Conference on Electrical Insulation.

[4]  Luciano Simoni General Equation of the Decline in the Electric Strength for Combined Thermal and Electrical Stresses , 1984, IEEE Transactions on Electrical Insulation.

[5]  S. A. Drinkut,et al.  Radio Frequency Sensing of Incipient Arcing Faults within Large Turbine Generators , 1979, IEEE Transactions on Power Apparatus and Systems.

[6]  A. Krivda,et al.  Automated recognition of partial discharges , 1995 .

[7]  M. B. Srinivas,et al.  Pulse-count distribution as a possible diagnostic tool for assessing the level of degradation of rotating machine insulation , 1990 .

[8]  M. B. Srinivas,et al.  Multistress aging of epoxy-mica insulation system , 1992, [Proceedings] 1992 Annual Report: Conference on Electrical Insulation and Dielectric Phenomena.

[9]  J. K. Nelson,et al.  Assessment of deterioration in epoxy/mica machine insulation , 1992 .

[10]  F. T. Emery Partial discharge activity in high voltage stator coils , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[11]  K. Kimura Progress of insulation ageing and diagnostics of high voltage rotating machine windings in Japan , 1993, IEEE Electrical Insulation Magazine.

[12]  S. Azizi-Ghannad,et al.  An acoustic diagnostic technique for use with electric machine insulation , 1994 .

[13]  Thomas W. Dakin,et al.  Electrical Insulation Deterioration Treated as a Chemical Rate Phenomenon , 1948, Transactions of the American Institute of Electrical Engineers.

[14]  Paavo Paloniemi,et al.  Theory of Equalization of Thermal Ageing Processes of Electrical Insulating Materialsin Thermal Endurance Tests I: Review of Theoretical Basis of Test Methods and Chemical and Physical Aspects of Ageing , 1981, IEEE Transactions on Electrical Insulation.

[15]  Alfredo Contin,et al.  Diagnosis of practical insulation systems by partial discharge measurements in the presence of multi-discharge phenomena , 1993, Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93).

[16]  D. W. Auckland,et al.  Detecting and classifying flaws within insulating materials using ultrasound , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[17]  H. G. Sedding,et al.  The ability of diagnostic tests to estimate the remaining life of stator insulation , 1988 .

[18]  Yasuhiko Kako,et al.  Capability of Insulation Diagnosis for Mica-Resin Insulated Coils , 1980, IEEE Transactions on Electrical Insulation.

[19]  S.C. Barton,et al.  Implementation of Pyrolysate Analysis of Materials Employing Tagging Compounds to Locate an Overheated Area in a Generator , 1981, IEEE Transactions on Power Apparatus and Systems.

[20]  J. R. Laghari,et al.  Models for insulation aging under electrical and thermal multistress , 1990 .

[21]  J.K. Nelson,et al.  An automated system for measurement of partial discharges in HV generator insulation utilizing a conventional oscilloscope , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[22]  H. Yoshida,et al.  Insulation Diagnosis for Rotating Machine Insulation , 1986, IEEE Transactions on Electrical Insulation.

[23]  J. H. Mason Discharge detection and measurements , 1965 .

[24]  K. Kadotani,et al.  A Proposal for Insulation Diagnosis of 3 KV Motor Stator Windings , 1983, IEEE Transactions on Electrical Insulation.