Real-time feedback control of pH within microfluidics using integrated sensing and actuation.

We demonstrate a microfluidic system which applies engineering feedback principles to control the pH of a solution with a high degree of precision. The system utilizes an extended-gate ion-sensitive field-effect transistor (ISFET) along with an integrated pseudo-reference electrode to monitor pH values within a microfluidic reaction chamber. The monitored reaction chamber has an approximate volume of 90 nL. The pH value is controlled by adjusting the flow through two input channels using a pulse-width modulated signal applied to on-chip integrated valves. We demonstrate real-time control of pH through the feedback-controlled stepping of 0.14 pH increments in both the increasing and decreasing direction. The system converges to the pH setpoint within approximately 20 seconds of a step change. The integration of feedback theory into a microfluidic environment is a necessary step for achieving complete control over the microenvironment.

[1]  Z. Li,et al.  Optimal and consistent protein glycosylation in mammalian cell culture. , 2009, Glycobiology.

[2]  S. Jeanneret,et al.  Integrated flow-regulated silicon micropump , 1994 .

[3]  Harry L. T. Lee,et al.  Microbioreactor arrays with integrated mixers and fluid injectors for high-throughput experimentation with pH and dissolved oxygen control. , 2006, Lab on a chip.

[4]  D. Beebe,et al.  Fundamentals of microfluidic cell culture in controlled microenvironments. , 2010, Chemical Society reviews.

[5]  Hsueh-Chia Chang,et al.  Microscale pH regulation by splitting water. , 2011, Biomicrofluidics.

[6]  J Alexander Liddle,et al.  Multiple electrokinetic actuators for feedback control of colloidal crystal size. , 2012, Lab on a chip.

[7]  Aaron R Wheeler,et al.  A feedback control system for high-fidelity digital microfluidics. , 2011, Lab on a chip.

[8]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[9]  Nancy Y. Ip,et al.  Precise temperature control of microfluidic chamber for gas and liquid phase reactions , 2000 .

[10]  Charles M Schroeder,et al.  Microfluidic Wheatstone bridge for rapid sample analysis. , 2011, Lab on a chip.

[11]  Luke P. Lee,et al.  Single-cell electroporation arrays with real-time monitoring and feedback control. , 2007, Lab on a chip.

[12]  Themistoklis Prodromakis,et al.  A Low-Cost Disposable Chemical Sensing Platform Based on Discrete Components , 2011, IEEE Electron Device Letters.

[13]  Lienhard Pagel,et al.  A microfluidic pH-regulation system based on printed circuit board technology , 2000 .

[14]  Wang Gui-hua,et al.  Time-dependent response characteristics of pH-sensitive ISFET , 1991 .

[15]  E. A. Lima,et al.  Thin-film IrOx pH microelectrode for microfluidic-based microsystems. , 2005, Biosensors & bioelectronics.

[16]  Gary J. Lye,et al.  pH control in microwell fermentations of S. erythraea CA340: influence on biomass growth kinetics and erythromycin biosynthesis , 2003 .

[17]  Antti Niemistö,et al.  Image-based feedback control for real-time sorting of microspheres in a microfluidic device. , 2010, Lab on a chip.

[18]  Andreas G. Andreou,et al.  Design, Fabrication, and Testing of a Hybrid CMOS/PDMS Microsystem for Cell Culture and Incubation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[19]  J. Santiago,et al.  Basic principles of electrolyte chemistry for microfluidic electrokinetics. Part I: Acid-base equilibria and pH buffers. , 2009, Lab on a chip.

[20]  Mario Rotea,et al.  Microfluidic device incorporating closed loop feedback control for uniform and tunable production of micro-droplets. , 2010, Lab on a chip.

[21]  Robin H. Liu,et al.  An organic self-regulating microfluidic system. , 2001, Lab on a chip.

[22]  Ralph G Nuzzo,et al.  An electrochemically driven poly(dimethylsiloxane) microfluidic actuator: oxygen sensing and programmable flows and pH gradients. , 2005, Lab on a chip.

[23]  A. deMello Control and detection of chemical reactions in microfluidic systems , 2006, Nature.

[24]  W. Messner,et al.  Pressure-driven spatiotemporal control of the laminar flow interface in a microfluidic network. , 2007, Lab on a chip.

[25]  M. Gilson,et al.  Prediction of pH-dependent properties of proteins. , 1994, Journal of molecular biology.

[26]  Brandon Kuczenski,et al.  Modulation of fluidic resistance and capacitance for long-term, high-speed feedback control of a microfluidic interface. , 2009, Lab on a chip.

[27]  A. Errachid,et al.  ION-SENSITIVE FIELD-EFFECT TRANSISTORS FABRICATED IN A COMMERCIAL CMOS TECHNOLOGY , 1999 .

[28]  W. Dötzel,et al.  Hybrid-assembled micro dosing system using silicon-based micropump/ valve and mass flow sensor , 1998 .

[29]  T. Welton,et al.  Precise temperature control in microfluidic devices using Joule heating of ionic liquids. , 2004, Lab on a chip.

[30]  Wouter Olthuis,et al.  A closed-loop controlled electrochemically actuated micro-dosing system , 2000 .