A field-programmable gate array based system for high frame rate laser Doppler blood flow imaging

This paper presents a general embedded processing system implemented in a field-programmable gate array providing high frame rate and high accuracy for a laser Doppler blood flow imaging system. The proposed system can achieve a basic frame rate of flow images at 1 frame/second for 256×256 images with 1024 fast Fourier transform (FFT) points used in the processing algorithm. Mixed fixed-floating point calculations are utilized to achieve high accuracy but with a reasonable resource usage. The implementation has a root mean square deviation of the relative difference in flow values below 0.1% when compared with a double-precision floating point implementation. The system can contain from one or more processing units to obtain the required frame rate and accuracy. The performance of the system is significantly higher than other methods reported to date. Furthermore, a dedicated field-programmable gate array (FPGA) board has been designed to test the proposed processing system. The board is linked with a laser line scanning system, which uses a 64×1 photodetector array. Test results with various operating parameters show that the performance of the new system is better, in terms of noise and imaging speed, than has been previously achieved.

[1]  Stephen P Morgan,et al.  Laser Doppler blood flow complementary metal oxide semiconductor imaging sensor with analog on-chip processing. , 2008, Applied optics.

[2]  P O Byrne,et al.  A laser Doppler scanner for imaging blood flow in skin. , 1991, Journal of biomedical engineering.

[3]  Ton van Leeuwen,et al.  Twente Optical Perfusion Camera: system overview and performance for video rate laser Doppler perfusion imaging. , 2009, Optics express.

[4]  J. Briers,et al.  Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. , 2001, Physiological measurement.

[5]  Stephen P. Morgan,et al.  Full field laser Doppler flowmetry with custom made CMOS sensors , 2009, BiOS.

[6]  Stephen P. Morgan,et al.  Complementary metal-oxide-semiconductor imaging array with laser Doppler blood flow processing , 2008 .

[7]  Theo Lasser,et al.  High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor. , 2005, Optics express.

[8]  J. Tulip,et al.  A comparison of two laser-based methods for determination of burn scar perfusion: laser Doppler versus laser speckle imaging. , 2005, Burns : journal of the International Society for Burn Injuries.

[9]  Stephen P. Morgan,et al.  Laser Doppler blood flowmetry with FPGA processing , 2004, Advanced Laser Technologies.

[10]  P A Oberg,et al.  Spatial and temporal variations in human skin blood flow. , 1983, International journal of microcirculation, clinical and experimental.

[11]  G. A. Holloway,et al.  Laser Doppler evaluation of burned hands predicts need for surgical grafting. , 1997, The Journal of trauma.

[12]  Wiendelt Steenbergen,et al.  Laser Doppler perfusion imaging with a complimentary metal oxide semiconductor image sensor. , 2002, Optics letters.

[13]  P. Farr,et al.  The study of plaques of psoriasis using a scanning laser‐Doppler velocimeter , 1993, The British journal of dermatology.

[14]  Y. Yeh,et al.  Localized fluid flow measurements with an He-Ne laser spectrometer , 1964 .

[15]  Barrie Hayes-Gill,et al.  An FPGA based generic prototyping platform employed in a CMOS laser Doppler blood flow camera , 2006, 2006 IEEE International Conference on Field Programmable Technology.

[16]  Theo Lasser,et al.  Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera. , 2005, Optics express.

[17]  M. Stern,et al.  In vivo evaluation of microcirculation by coherent light scattering , 1975, Nature.

[18]  P. Blondeel,et al.  Doppler flowmetry in the planning of perforator flaps. , 1998, British journal of plastic surgery.