Entropy generation minimization of combined heat and mass transfer devices

Abstract This paper details a simple procedure by which the entropy generation in simultaneous heat and mass exchange devices can be minimized. Effectiveness for these devices is defined and a new parameter, ‘modified heat capacity rate ratio’ is introduced. It is found that the entropy generation of a combined heat and mass exchange device is minimized (at constant value of effectiveness) when the modified heat capacity rate ratio is equal to one irrespective of the value of other independent parameters. Several typical examples of the cooling towers have been studied to illustrate this concept. A practical application of the concept is also illustrated using a humidification–dehumidification desalination system.

[1]  Ramesh K. Shah,et al.  Costs of Irreversibilities in Heat Exchanger Design , 1983 .

[2]  Mehmet Yilmaz,et al.  Performance evaluation criteria for heat exchangers based on second law analysis , 2001 .

[3]  John H. Lienhard,et al.  Thermodynamic analysis of humidification dehumidification desalination cycles , 2009 .

[4]  Adrian Bejan,et al.  The thermodynamic design of heat and mass transfer processes and devices , 1987 .

[5]  C. G. Carrington,et al.  Second law analysis of combined heat and mass transfer phenomena , 1991 .

[6]  A. Wexler,et al.  FORMULATIONS FOR THE THERMODYNAMIC PROPERTIES OF THE SATURATED PHASES OF H2O FROM 173.15 TO 473.15 K. , 1983 .

[7]  John H. Lienhard,et al.  The potential of solar-driven humidification–dehumidification desalination for small-scale decentralized water production , 2009 .

[8]  Hendrik Müller-Holst,et al.  SOLAR THERMAL DESALINATION USING THE MULTIPLE EFFECT HUMIDIFICATION (MEH)-METHOD , 2007 .

[9]  Radu Zmeureanu,et al.  Energy and exergy performance of residential heating systems with separate mechanical ventilation , 2007 .

[10]  Sunil Sarangi,et al.  On the generation of entropy in a counterflow heat exchanger , 1982 .

[11]  Muhsin Kilic,et al.  Second law-based thermodynamic analysis of water-lithium bromide absorption refrigeration system , 2007 .

[12]  J. E. Hesselgreaves Rationalisation of second law analysis of heat exchangers , 2000 .

[13]  R. Cornelissen,et al.  Thermodynamic optimisation of a heat exchanger , 1999 .

[14]  W. Wagner,et al.  The IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use , 2002 .

[15]  Enrico Sciubba,et al.  A minimum entropy generation procedure for the discrete pseudo-optimization of finned-tube heat exchangers , 1996 .

[16]  Larry C. Witte,et al.  A Thermodynamic Efficiency Concept for Heat Exchange Devices , 1983 .

[17]  DUSáAN P. SEKULICá Entropy Generation in a Heat Exchanger , 1986 .

[18]  Hisham Ettouney,et al.  Solar Desalination for the 21st Century , 2007 .

[19]  Syed M. Zubair,et al.  A complete model of wet cooling towers with fouling in fills , 2006 .

[20]  J. Marzbanrad,et al.  Thermodynamic Optimization of GSHPS Heat Exchangers , 2007 .

[21]  Z. Lavan,et al.  Entropy generation in combined heat and mass transfer , 1987 .

[22]  Per Lundqvist,et al.  A year-round dynamic simulation of a solar-driven ejector refrigeration system with iso-butane as a refrigerant , 2007 .

[23]  John H. Lienhard,et al.  Effect of entropy generation on the performance of humidification-dehumidification desalination cycles , 2010 .