Body mass and corrective factor: impact on temperature-based death time estimation

Model-based methods play an important role in temperature-based death time determination. The most prominent method uses Marshall and Hoare's double exponential model with Henssge's parameter determination. The formulae contain body mass as the only non-temperature parameter. Henssge's method is well established since it can be adapted to non-standard cooling situations varying the parameter body mass by multiplying it with the corrective factor. The present study investigates the influence of measurement errors of body mass m as well as of variations of the corrective factor c on the error of the Marshall and Hoare–Henssge death time estimator tD. A formula for the relative error of tD as a function of the relative error of m is derived. Simple approximations of order 1 and 0 nevertheless yield acceptable results validated by Monte Carlo simulations. They also provide the rule of thumb according to which the quotient of the standard deviations D(tD) of the estimated death time and D(m) of the body mass is equal to the quotient of the estimated death time tD and the body mass m (D(tD)/D(m) ≈ tD/m). Additionally, formulae and their approximations are derived to quantify the influence of Henssge's body mass corrective factor c on death time estimation. In a range of body masses between 50 and 150 kg, the relative variation of the body mass corrective factor is approximately equal to the relative variation of the death time (ΔtD = (tD/c)Δc). This formula is applied and compared to computations and to experimental cooling data with good results.

[1]  M A Green,et al.  Postmortem interval estimation from body temperature data only. , 1985, Forensic science international.

[2]  G. Webster,et al.  Post-Mortem Temperature and the Time of Death , 1955 .

[3]  C. L. Lim,et al.  Human thermoregulation and measurement of body temperature in exercise and clinical settings. , 2008, Annals of the Academy of Medicine, Singapore.

[4]  V. Schneider,et al.  Experiences with a compound method for estimating the time since death , 2000, International Journal of Legal Medicine.

[5]  F. Lundquist Physical and chemical methods for the estimation of the time of death. , 1956, Acta medicinae legalis et socialis.

[6]  L. Nokes,et al.  Estimation of the post mortem period by multiple-site temperature measurements and the use of a new algorithm. , 1988, Forensic science international.

[7]  C. Henßge Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung unter verschiedenen Abkühlungsbedingungen , 2004, Zeitschrift für Rechtsmedizin.

[8]  O. Peschel,et al.  Temperature-based death time estimation with only partially known environmental conditions , 2005, International Journal of Legal Medicine.

[9]  C. Henssge Rectal temperature time of death nomogram: dependence of corrective factors on the body weight under stronger thermic insulation conditions. , 1992, Forensic science international.

[10]  Michael Hubig,et al.  Influence of measurement errors on temperature-based death time determination , 2010, International Journal of Legal Medicine.

[11]  T. K. Marshall,et al.  The use of Body Temperature in Estimating the Time of Death and its Limitations , 1969, Medicine, science, and the law.

[12]  Y. Çengel Heat Transfer: A Practical Approach , 1997 .

[13]  B. Brinkmann,et al.  Handbuch gerichtliche Medizin , 2003 .

[14]  K Hiraiwa,et al.  Estimation of Postmortem Interval from Rectal Temperature by Use of Computer (III)—Thermal Conductivity of the Skin , 1982, Medicine, science, and the law.

[15]  C. Henßge Die Präzision von Todeszeitschätzungen durch die mathematische Beschreibung der rektalen Leichenabkühlung , 1979, Zeitschrift für Rechtsmedizin.

[16]  B. Madea,et al.  Methoden zur Bestimmung der Todeszeit an Leichen , 1988 .

[17]  C Henssge,et al.  Death time estimation in case work. I. The rectal temperature time of death nomogram. , 1988, Forensic science international.

[18]  S. Maruyama,et al.  Effects of rounding errors on postmortem temperature measurements caused by thermometer resolution , 2007, International Journal of Legal Medicine.