Changes in mitral valve annular geometry after repair: saddle-shaped versus flat annuloplasty rings.

BACKGROUND Saddle-shaped annuloplasty rings are being increasingly used during mitral valve (MV) repair to conform the mitral annulus to a more nonplanar shape and possibly reduce leaflet stress. In this study utilizing three-dimensional transesophageal echocardiography we compared the effects of rigid flat rings with those of the saddle rings on the mitral annular geometry. Specifically we measured the changes in nonplanarity angle (NPA) before and after MV repair. METHODS Geometric analysis on 38 patients undergoing MV repair for myxomatous and ischemic mitral regurgitation with full flat rings (n = 18) and saddle rings (n = 18) were performed. The acquired three-dimensional volumetric data were analyzed utilizing the "Image Arena" software (TomTec GmBH, Munich, Germany). Specifically, the degree of change in the NPA was calculated and compared before and after repair for both types of rings. RESULTS Both types of annuloplasty rings resulted in significant changes in the geometric structure of the MV after repair. However, saddle rings lead to a decrease in the NPA (7% for ischemic and 8% for myxomatous MV repairs) (ie, made the annulus more nonplanar), whereas flat rings increased the NPA (7.9% for ischemic and 11.8% for myxomatous MV repairs) (ie, made the annulus less nonplanar); p value 0.001 or less. CONCLUSIONS Implantation of saddle-shaped rings during MV repair surgery is associated with augmentation of the nonplanar shape of the mitral annulus (ie, decreases NPA). This favorable change in the mitral annular geometry could possibly confer a structural advantage to MV repairs with the saddle rings.

[1]  M. Bourgeois,et al.  Size and motion of the mitral valve annulus in anesthetized intact dogs. , 1971, Journal of applied physiology.

[2]  F. Bowen,et al.  Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet Stress , 2002, Circulation.

[3]  A. Young,et al.  Three‐Dimensional Left Ventricular Deformation in Hypertrophic Cardiomyopathy , 1994, Circulation.

[4]  J. Gorman,et al.  Regional and global patterns of annular remodeling in ischemic mitral regurgitation. , 2007, The Annals of thoracic surgery.

[5]  T. Akasaka,et al.  Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane transesophageal echocardiography: comparison between flexible and rigid annuloplasty rings. , 1995, The Journal of heart valve disease.

[6]  Joseph H. Gorman,et al.  Three-dimensional echocardiographic assessment of changes in mitral valve geometry after valve repair. , 2009, The Annals of thoracic surgery.

[7]  Peter Johansen,et al.  What forces act on a flat rigid mitral annuloplasty ring? , 2008, The Journal of heart valve disease.

[8]  A F Bolger,et al.  Three-dimensional regional dynamics of the normal mitral anulus during left ventricular ejection. , 1996, The Journal of thoracic and cardiovascular surgery.

[9]  James D. Thomas,et al.  Acute Geometric Changes of the Mitral Annulus after Coronary Occlusion: A Real-Time 3D Echocardiographic Study , 2006, Journal of Korean medical science.

[10]  A. Bolger,et al.  Loss of three-dimensional canine mitral annular systolic contraction with reduced left ventricular volumes. , 1996, Circulation.

[11]  John Mitchell,et al.  Intraoperative application of geometric three-dimensional mitral valve assessment package: a feasibility study. , 2008, Journal of cardiothoracic and vascular anesthesia.

[12]  A. Bolger,et al.  Three-dimensional dynamics of the canine mitral annulus during ischemic mitral regurgitation. , 1996, The Annals of thoracic surgery.

[13]  C Uyama,et al.  Mitral annular function assessed by 3D imaging for mitral valve surgery. , 1994, The Journal of heart valve disease.

[14]  Robert C Gorman,et al.  The influence of annuloplasty ring geometry on mitral leaflet curvature. , 2008, The Annals of thoracic surgery.

[15]  A. Bruschke,et al.  Comparison of rigid and flexible rings for annuloplasty of the porcine mitral valve. , 1990, Circulation.

[16]  Robert C Gorman,et al.  Description of regional mitral annular nonplanarity in healthy human subjects: a novel methodology. , 2007, The Journal of thoracic and cardiovascular surgery.

[17]  C. Tei,et al.  Size and Motion of the Mitral Valve Annulus in Man: I. A Two‐dimensional Echocardiographic Method and Findings in Normal Subjects , 1981, Circulation.

[18]  R A Levine,et al.  The relationship of mitral annular shape to the diagnosis of mitral valve prolapse. , 1987, Circulation.

[19]  J. Thomas,et al.  Cosgrove-Edwards Annuloplasty System: midterm results. , 2000, The Annals of thoracic surgery.

[20]  Robert C Gorman,et al.  Annuloplasty ring selection for chronic ischemic mitral regurgitation: lessons from the ovine model. , 2003, The Annals of thoracic surgery.

[21]  David Liang,et al.  Effects of Paracommissural Septal-Lateral Annular Cinching on Acute Ischemic Mitral Regurgitation , 2004, Circulation.

[22]  J. Mark,et al.  ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certifi , 1999, Journal of the American Society of Echocardiography.

[23]  Ajit P Yoganathan,et al.  Saddle-Shaped Mitral Valve Annuloplasty Rings Experience Lower Forces Compared With Flat Rings , 2008, Circulation.

[24]  David Liang,et al.  Annular remodeling in chronic ischemic mitral regurgitation: ring selection implications. , 2003, The Annals of thoracic surgery.

[25]  Natesa G Pandian,et al.  Percutaneous mitral valve repair: A feasibility study in an ovine model of acute ischemic mitral regurgitation , 2003, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[26]  V. Jeevanandam,et al.  Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[27]  James D. Thomas,et al.  Geometric changes of mitral annulus assessed by real-time 3-dimensional echocardiography: becoming enlarged and less nonplanar in the anteroposterior direction during systole in proportion to global left ventricular systolic function. , 2004, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.