Numerical investigation of smoke exhaust mechanism in a gymnasium under fire scenarios

Abstract The Fire Dynamics Simulator code is used to investigate the smoke filling process in a large building. Initially, the model is used to simulate the smoke descending process in an atrium under fire scenarios. By comparing with experimental data, reasonable model constants of C s and Pr t are determined for simulating smoke movement in buildings with large space. The performance of different smoke exhaust methods in a real gymnasium is then studied. Smoke filling processes are investigated under different natural and enhanced smoke exhaust methods. Simulated results show that natural smoke exhaust method is preferred when the smoke exhaust vents are located at the ceiling of the gymnasium. On the other hand, when the smoke exhaust vents are located on the walls of the gymnasium, enhanced smoke exhaust methods are preferred. In addition, the influence of ceiling temperature in the gymnasium on the smoke spreading process is presented in this paper. Results indicate that high ceiling temperature slows down the so-called smoke ceiling jet moving horizontally at the ceiling, whereas low ceiling temperature accelerates such smoke ceiling jets.

[1]  J. Ferziger,et al.  Evaluation of subgrid-scale models using an accurately simulated turbulent flow , 1979, Journal of Fluid Mechanics.

[2]  Wan Ki Chow,et al.  Natural smoke filling in atrium with liquid pool fires up to 1.6 MW , 2001 .

[3]  Joseph C. Lam,et al.  CFD analysis and energy simulation of a gymnasium , 2001 .

[4]  Wan Ki Chow,et al.  A new model on simulating smoke transport with computational fluid dynamics , 2004 .

[5]  P. Moin,et al.  Numerical investigation of turbulent channel flow , 1981, Journal of Fluid Mechanics.

[6]  Wan Ki Chow,et al.  A simple two-layer zone model on mechanical exhaust in an atrium , 2005 .

[7]  Wan Ki Chow,et al.  Plume equations for studying smoke-filling process in atria with a zone model , 1997 .

[8]  Tokiyoshi Yamada,et al.  Smoke control based on a solar-assisted natural ventilation system , 2004 .

[9]  Glenn P. Forney,et al.  Fire Dynamics Simulator: Technical Reference Guide (NISTIR 6467) , 2000 .

[10]  Weigang Zhang,et al.  Turbulence statistics in a fire room model by large eddy simulation , 2002 .

[11]  Li Yuan Studies of Smoke Filling Process in Large Spaces , 2001 .

[12]  Belinda L Collins,et al.  Evaluation of exit signs in clear and smoke conditions , 1990 .

[13]  Clayton Huggett,et al.  Estimation of rate of heat release by means of oxygen consumption measurements , 1980 .

[14]  H. Baum,et al.  Large eddy simulations of smoke movement , 1998 .

[15]  Wan Ki Chow,et al.  Experimental Studies on Natural Smoke Filling in Atria , 2000 .

[16]  J. Smagorinsky,et al.  GENERAL CIRCULATION EXPERIMENTS WITH THE PRIMITIVE EQUATIONS , 1963 .

[17]  James A. Milke Effectiveness of High-Capacity Smoke Exhaust in Large Spaces , 2003 .

[18]  W. Grosshandler Radcal: A Narrow-Band Model for Radiation Calculations in a Combustion Environment , 2018 .

[19]  Li Yuanzhou,et al.  Study of Smoke Filling Processes in an Atrium , 1999 .

[20]  Shuzo Murakami,et al.  Overview of turbulence models applied in CWE–1997 , 1998 .