Double-Field Hadrontherapy Treatment Monitoring With the INSIDE In-Beam PET Scanner: Proof of Concept

Positron emission tomography (PET) is a well established imaging technique for range monitoring in hadrontherapy. Multiple fields are standard protocol in treatments, but because of washout and residual activity background from previous irradiation plans, to this date quantitative verification of the particle range for each beam field is still an open issue. In this paper, a new method for the evaluation with a PET detector of the activity range of the second field of a treatment is discussed. Two treatment plans with two parallel-opposed beam fields, one using protons and one using carbon ions, were delivered on PMMA phantoms. In both cases, the second beam field was extracted from the first irradiation residual activity and compared with a reference image, obtained from the experimental acquisition of the second field alone. Results demonstrate good agreement between the extracted second field and the reference image, with average difference in the activity range along the preferential direction of the beam less than 0.5 mm for protons, and 1.5 mm for carbon ions. Without taking into account any preferential direction, differences within 0.5 mm were found for both cases. The method will soon be tested with nonhomogeneous phantoms and, subsequently, with in-vivo clinical data.

[1]  Nicola Belcari,et al.  Positron Emission Tomography: Its 65 years , 2016 .

[2]  Marco Durante,et al.  Nuclear physics in particle therapy: a review , 2016, Reports on progress in physics. Physical Society.

[3]  V. Ferrero The INSIDE project: on-line monitoring and simulation validation with the in-beam PET scanner , 2017 .

[4]  Wolfgang Birkfellner,et al.  Using statistical measures for automated comparison of in-beam PET data. , 2012, Medical physics.

[5]  Katia Parodi,et al.  Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy. , 2007, International journal of radiation oncology, biology, physics.

[6]  Piergiorgio Cerello,et al.  INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy , 2016, Journal of medical imaging.

[7]  S Giordanengo,et al.  The CNAO dose delivery system for modulated scanning ion beam radiotherapy. , 2014, Medical physics.

[8]  Keiichi Nakagawa,et al.  The development and clinical use of a beam ON-LINE PET system mounted on a rotating gantry port in proton therapy. , 2008, International journal of radiation oncology, biology, physics.

[9]  R. Bugalho,et al.  TOFPET ASIC for PET applications , 2013 .

[10]  W. Enghardt,et al.  Online Irradiation Control by Means of PET , 2012 .

[11]  Denis Dauvergne,et al.  Prompt-gamma monitoring in hadrontherapy: A review , 2018 .

[12]  Harald Paganetti,et al.  Clinical application of in-room positron emission tomography for in vivo treatment monitoring in proton radiation therapy. , 2013, International journal of radiation oncology, biology, physics.

[13]  F. Licciulli,et al.  A study of monitoring performances with the INSIDE system , 2015 .

[14]  K. Perez Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2014 .

[15]  Julia Bauer,et al.  Sensitivity of post treatment positron emission tomography/computed tomography to detect inter-fractional range variations in scanned ion beam therapy , 2017, Acta oncologica.

[16]  G Baroni,et al.  Monte Carlo simulation tool for online treatment monitoring in hadrontherapy with in-beam PET: A patient study. , 2018, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[17]  Riccardo Paramatti,et al.  Monitoring of Hadrontherapy Treatments by Means of Charged Particle Detection , 2016, Front. Oncol..

[18]  Katia Parodi,et al.  Implementation and workflow for PET monitoring of therapeutic ion irradiation: a comparison of in-beam, in-room, and off-line techniques , 2011, Physics in medicine and biology.

[19]  Richard Wheadon,et al.  First results of the INSIDE in-beam PET scanner for the on-line monitoring of particle therapy treatments , 2016 .

[20]  H. Paganetti Range uncertainties in proton therapy and the role of Monte Carlo simulations , 2012, Physics in medicine and biology.

[21]  Katia Parodi,et al.  Charged hadron tumour therapy monitoring by means of PET , 2004 .

[22]  Veronica Ferrero The INSIDE project: in-beam PET scanner system features and characterization , 2017 .

[23]  H Paganetti,et al.  Quantitative assessment of the physical potential of proton beam range verification with PET/CT , 2008, Physics in medicine and biology.

[24]  Piergiorgio Cerello,et al.  Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET , 2018, Scientific Reports.

[25]  P. Cerello,et al.  Monte Carlo simulations for in-beam PET monitoring in hadron-therapy , 2014 .

[26]  Piergiorgio Cerello,et al.  Carbon ions beam therapy monitoring with the INSIDE in-beam PET. , 2018, Physics in medicine and biology.

[27]  Antony Lomax,et al.  In vivo proton range verification: a review , 2013, Physics in medicine and biology.

[28]  H Paganetti,et al.  Automation and uncertainty analysis of a method for in-vivo range verification in particle therapy , 2014, Physics in medicine and biology.

[29]  G Sportelli,et al.  First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system , 2014, Physics in medicine and biology.

[30]  E. Fiorina An integrated system for the online monitoring of particle therapy treatment accuracy , 2016 .