New posturographic assessment by means of novel e-textile and wireless socks device

The quantitative assessment of the postural stability is allowed by means of the use of pressure or force plates which are able to record a CoP subject's trajectory during a quite standing. However, the pressure or force plates are commonly used in a clinical environment, due to their very complexity and expensiveness. So their applicability outside laboratories is extremely limited. New e-textile and wireless wearable sensor technologies enable to extend the posturography in new low-cost and home assessment contexts. Twenty posturographic tests has been performed on normal subjects at the same time both by pressure signals derived by Sensoria fitness (SF) e-textile socks and by a gold standard stabilometric Zebris platform (ZP). Preliminary results showed a significant agreement between SF and ZP COP measurements, suggesting a clinical use of Sensoria for low cost home care based balance impairment assessments.

[1]  Maria Romano,et al.  The effects of the vibratory stimulation of the neck muscles for the evaluation of stepping performance in Parkinson's Disease , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[2]  M L Latash,et al.  Anticipatory postural adjustments in conditions of postural instability. , 1998, Electroencephalography and clinical neurophysiology.

[3]  Maria Romano,et al.  Submovements composition and quality assessment of reaching movements in subjects with Parkinson's Disease , 2015, 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) Proceedings.

[4]  D. Winter A.B.C. (anatomy, biomechanics and control) of balance during standing and walking , 1995 .

[5]  Erik M. Bollt,et al.  A Quiet Standing Index for Testing the Postural Sway of Healthy and Diabetic Adults Across a Range of Ages , 2009, IEEE Transactions on Biomedical Engineering.

[6]  F. Horak,et al.  Postural perturbations: new insights for treatment of balance disorders. , 1997, Physical therapy.

[7]  Thomas Prieto,et al.  Characterization and modeling of postural steadiness in the elderly: a review , 1993 .

[8]  G. D'Addio,et al.  Changes in frequency components of blood flow oscillations in hyperglycemic obese people , 2014, 2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO).

[9]  Paolo Bifulco,et al.  Frequency domain and symbolic dynamics analysis for the study of cardiac pathologies , 2013, 2013 E-Health and Bioengineering Conference (EHB).

[10]  Maria Romano,et al.  Analysis of Foetal Heart Rate Variability Components by Means of Empirical Mode Decomposition , 2016 .

[11]  Pasquale Arpaia,et al.  A low-cost force sensor-based posturographic plate for home care telerehabilitation exergaming , 2014 .

[12]  Maria Romano,et al.  Frequency and Time Domain Analysis of Foetal Heart Rate Variability with Traditional Indexes: A Critical Survey , 2016, Comput. Math. Methods Medicine.

[13]  Y. Pai,et al.  Center of mass velocity-position predictions for balance control. , 1997, Journal of biomechanics.

[14]  J Middleton,et al.  Accuracy of centre of pressure measurement using a piezoelectric force platform. , 1999, Clinical biomechanics.

[15]  Paolo Bifulco,et al.  Effects of wavelets analysis on power spectral distributions in laser doppler flowmetry time series , 2014 .

[16]  Paolo Bifulco,et al.  Comparison between clinical and instrumental assessing using Wii Fit system on balance control , 2014, 2014 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[17]  H J Stam,et al.  Techniques for measuring weight bearing during standing and walking. , 2003, Clinical biomechanics.

[18]  G. D'Addio,et al.  Microvascular blood flow regulation impairments in hypertensive obese people , 2014, 2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO).

[19]  Pasquale Arpaia,et al.  A balance board device for home care telerehabilitation exergaming , 2012 .

[20]  Maria Romano,et al.  Bioengineering activities in proprioceptive and robotic rehabilitation at Salvatore Maugeri Foundation , 2015, 2015 AEIT International Annual Conference (AEIT).

[21]  Tutut Herawan,et al.  Computational and mathematical methods in medicine. , 2006, Computational and mathematical methods in medicine.

[22]  H. Simonsen,et al.  Comparison of Kistler 9861A force platform and Chattecx Balance System® for measurement of postural sway: correlation and test–retest reliability , 2003, Scandinavian journal of medicine & science in sports.

[23]  P. Goldie,et al.  Force platform measures for evaluating postural control: reliability and validity. , 1989, Archives of physical medicine and rehabilitation.

[24]  Angelo Cappello,et al.  Identification of distinct characteristics of postural sway in Parkinson's disease: A feature selection procedure based on principal component analysis , 2006, Neuroscience Letters.

[25]  S. Lord,et al.  Balance disorders in the elderly , 2008, Neurophysiologie Clinique/Clinical Neurophysiology.